• Title/Summary/Keyword: hand measurement

Search Result 1,074, Processing Time 0.033 seconds

A Study on the Measurement of Korean Hand - Focusing on Glove & Hand Dimension - (한국인을 위한 장갑 패턴 고찰 (1) - 업체 조사를 통한 손계측 항목을 중심으로 -)

  • Ryu, Kyoung-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.5
    • /
    • pp.866-877
    • /
    • 2009
  • The purpose of this study was to develop the dimension of hand pattern-making for Korean glove. The glove pattern-making has difficult problem in combination of anthropometric and engineering aspects. In addition, existing dimension data are not enough for glove pattern-making. Therefore, to develop the dimension for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over the 15 years) were interviewed on the method of glove. The result of comparing between the structures in hand and existing glove pattern, there draw deduction from follows. Pattern-making for glove need size of hand length, thumb length, index finger length, middle finger length, ring finger length, hand circumference, thumb-ring finger circumference and maximum hand thickness.

  • PDF

Manufacturing of a Korean Hand Phantom with Human Electrical Properties at 835 MHz and 1,800 MHz Bands (835 MHz 및 1,800 MHz 대역에서 인체의 전기적 특성을 가지는 한국인 손 모양의 팬텀 제작)

  • Choi, Donggeun;Gimm, Yoonmyoung;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.534-540
    • /
    • 2013
  • Interest of the hand effect on the electromagnetic wave are internationally increasing with the increase of the use of the mobile phone. IEC TC106(International Electrotechnical Commission, Technical Committee 106) promotes international research exchange program in order to reflect the effect of human hands in the standard assessment method of human exposure dosimetry by the electromagnetic wave of mobile phones. Since current commercialized hand phantom is manufactured by taking into account the average size of westerners and provides only one grip posture, it imposes many restrictions on the accurate SAR measurement. Therefore, the development of proper hand phantom accounting for domestic situation and various grip posture capability is essential in order to analyze the accurate effect of human hand on the exposure estimation. In this paper, a jelly hand phantom suitable for Korean was manufactured with various grip posture capability at 835 MHz and 1,800 MHz bands. Although the tolerances of permittivity and conductivity of the manufactured hand phantom are with ${\pm}10%$ each, it was much less than CTIA(Cellular Telecommunication Industry Association) tolerance of ${\pm}20%$ at both bands. Its 3D CAD(3 Dimensional Computer Aided Design) file which was developed can be utilized for the simulation of human hand effect on SAR measurement of mobile phones. The findings in this study can be utilized for the analysis of human hand effect on SAR measurement of a mobile phone.

Measurement of fabric hand feeling by scanning fiber whisker with PSD

  • Cao, Li;Ohyama, Shinji;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1306-1309
    • /
    • 1997
  • Fabric hand feeling is an important property used in apparel industry. This paper shows a sensing method to output a fiber whisker's stick slip vibration by scanning it on the fabric. Then the vibration waveforms are transformed to the Symmetrized Dot Pattern images. Experimental results show that SDP images of fiber whisker's stik slip is potentially useful to the detection of fabric hand feeling values.

  • PDF

An Experimental Research for the Development of the Guideline of Low Vibration Hand Tools (저진동 공구 개발 가이드라인 구축을 위한 실험적 연구)

  • Jang, Han-Kee;Oh, Seung-Jun;Noh, Jong-Jin;Choi, Seok-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.880-883
    • /
    • 2006
  • The reduction of tool vibration has been a serious issue for both employers and workers because of the risks of vibration transmitted to the workers. In this study a hand-arm vibration measurement and evaluation system was developed based on ISO 5349:2001 and used for analyzing relation of vibration level and components of tools. This system consists of a notebook PC installed a LabVIEW program and the data acquisition system including two 3-axial accelerometers and a NI-DAQ card. Vibration measurement tests were conducted for eight angle grinders and four impact wrenches where 3 subjects were used for each of the tools. The relation between different components of each tool and its vibration total value made it possible to set-up a guideline of tool design. In the past engineers developed tools by using their experience and intuition, but by using this system it became possible to design tool components so as to minimize the risks of hand-transmitted vibration.

  • PDF

A Study on Actual Conditions and Sizing Systems of Domestic Glove Production Companies (국내 장갑 제조업체의 실태조사 및 치수체계에 관한 연구)

  • Choi Hei-Sun;Kim Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.2 s.92
    • /
    • pp.116-128
    • /
    • 2005
  • The aim of this study is to understand problems with both fit and sizing system of gloves by analyzing the glove production industries with an emphasis on the sizing system, production measurement system, and general marking situation. Also, to suggest the basic raw materials for improving sizing system for gloves, actual glove control sizes were compared to the anthropometric data of the previous study Fifteen domestic production companies were participated in this study-Domestic glove production companies established their own sizing system by copying inter-national brand's glove sizing system or by their experience. The Korean Standard of gloves and the 1997 Korean Standard Anthropometrics Measurement for producing glove patterns are not considered because of its discordance with the reality of the required measurements. Domestic glove production companies used different size designation and labeling system. Size measurement unit also showed difference among the glove production companies. Some companies used 'cm', some used 'mm', some used 'inch' for the measurement unit. In general, companies produced 5 to 4 sizes in one design of glove and the production was the highest in M and L size. In 9 out of 15 companies preferred control size as hand length and hand circumference. For reference size, most of the companies preferred finger circumference, finger length, palm length, hand breadth, crotch height, and hand thickness. Actual glove sizes were compared to the anthropometric data of the previous study. The results indicated that most of the measurements of actual glove sizes were significantly larger than the anthropometric data.

Trend of hand dimensions for Koreans and Comparison with foreigners' data (한국인 손 치수의 추세 변동 및 외국 자료와의 비교)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.3
    • /
    • pp.146-153
    • /
    • 2010
  • The purposes of this are (1) to present representative five hand dimensions by measurement year, (2) to investigate hand characteristics based on relative ratios of varying hand dimensions and (3) to compare Korean hand dimensions to other countries' data. Comparing to those of 1979, statures of 2004 increased by 3.0~3.5%, while males' hand dimensions of hand length, medius finger length, hand circumference, hand breadth and hand thickness decreased by 2.0~5.0%. Ratios of hand dimensions to those of medius finger were not significantly different depending upon age group and gender, but were significantly different depending upon races of Korean and American. Hand lengths of Koreans were shorter by about 4.0% than those of Japanese irrespective of gender, while the other compared dimensions for Koreans were larger than those of Japanese. Hand dimensions used in this study of Koreans were generally smaller that those of Americans. It is recommended from this study that when designing hand relevant things including glove, computer keyboard, smart phone key pad, etc., the different hand characteristics found in this study be fully reflected to develop competitive products.

Precision control of a mobile/task robot using visual information (비젼 정보를 이용한 이동/작업용 로봇의 정밀제어)

  • 한만용;이장명
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.71-79
    • /
    • 1997
  • This paper introduces a methodology of the precise control of a mobile/task robot using visual information captured bythe camera attached at the hand of the task robot. The major problem residing in the precise control of mobile/task robot is providing an accurate and stable base for the task robot through the precise control of mobile robot. On account of uncertainties on the surface, the precise control of mobile robot is not feasible without using external position sensor. In this paper, the methodology for the precise control of mobile robot is proposed, which recognizes the position of mobile robot using the camera attached at the hand of the task robot. While the task robot is approaching to an assembly part, the position of mobile robot is measured using the line correspondence between the image capturesd by the camera and the real assembly part, and using the kinematic transformation from the hand of the task robot to the mobile robot. To verify the solidness of this method, experimental data for the measurement of camera position/orientation and for the precise control of mobile robot using measurement are shown.

  • PDF

A Simple Dual-Antenna Diversity Gain Measurement System at 2.4GHz

  • Kim, Jin-Gyong;Chung, Kyung-Ho;Ho, Yo-Choul;Kim, Moon-Il
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.220-223
    • /
    • 2009
  • A simple measurement system is built to estimate the dual-antenna diversity gain at 2.4GHz easily in open lab environment. To obtain multipath fading propagation channel, the system consists of two transmission horn that placed on opposite direction and a rotating stage mechanically changing the position of test dual-antenna with time over distance greater than one wavelength. Estimated diversity is nearly same as theoretical value such that measured diversity gain of 30mm separated is about 6dB similar to theoretical value of 5.7dB and increases monotonically with the increasing separation distance as predicted by the theory. Proposed measurement system that is simple enough to fit in a small space can evaluate the performance of various dual-antennas with a reasonable accuracy with lower 5% difference between the ten sets of measured waveform distribution and theoretical Rayleigh cumulative distribution.

  • PDF

OWAS and EMG-based Mason's Physical Workload Measurement (OWAS 및 근전도 기반 석공 작업부하 비교연구)

  • Seo, Byoung-Wook;Lim, Tae-Kyung;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.194-195
    • /
    • 2015
  • Methods for measuring the physical workload of construction workers are classified into posture assessment techniques (i.e., OWAS, RULA, etc.) and physiological measurement techniques (i.e., EMG, heart rate, etc.). The one does not quantify the workload on a specific body part of a worker by considering the weight of the hand tools or materials on hand and time for holding a particular posture. This paper presents a procedure for evaluating a physical demand using the electromyography (EMG) sensor. This study compares the EMG measurement and the posture assessment. The case study is carried out on a masonry operation.

  • PDF

Trends in Standards and Regulations on Hand-arm Vibration (수완계 진동에 대한 규격제정 동향)

  • 장한기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.899-902
    • /
    • 2002
  • Effect of hand-transmitted vibration on human discomfort and health was reviewed. Since the effect by hand tool was more serious than those by any other vibration environments, western countries have protected hand tool workers by regulations. International organization for standardization legislate standard, ISO 5349, at 1979 for the measurement and evaluation of the effect. Afterwards, more than twenty standards on hand-arm vibration were enacted to Protect any damage of hand tool users. Even though Korea Standards adopted ISO 5349 in 2001, it is required an action plan should be applied to all of work environments, especially to the workers using pneumatic tool workwers such as miners, construction workers, and etc.

  • PDF