• Title/Summary/Keyword: hand measurement

Search Result 1,076, Processing Time 0.031 seconds

A Study on the Measurement of Male Korean Hand - Focusing on Glove Size -

  • Ryu, Kyung-ok;Suh, Mi-a
    • The International Journal of Costume Culture
    • /
    • v.6 no.2
    • /
    • pp.126-133
    • /
    • 2003
  • The purpose of this study was to develop the sizing system for men's glove. The combination of anthropometric and engineering aspects of glove pattern-making is difficult problem in engineering clothing. And the traditional measurements is not enough for glove. Therefore, to develop the hand measurement method and dimension for glove, a comprehensive list of candidate measurements was reviewed and the manufacturers (Their career was over the 15years) were interviewed on the method of glove pattern-making. This study was conducted traditional and creative 88 two-dimensional anthropometric measurements and 4 photometric measurements for glove pattern-making. In addition, 16 creative measurements were instrumented using a special hand measuring board for measuring of landmark locations on the hand. The subjects were 260 men's right hand in the age group of 18 to 35 years old in korea.

  • PDF

Measurement of Grip and Feed Force in the Evaluation of Hand-arm Vibration (수완계 진동 평가에 영향을 미치는 작용력의 측정)

  • 최석현;장한기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1038-1042
    • /
    • 2003
  • In order to evaluate dynamic impedance of a hand-arm system it is necessary to measure the hand-transmitted vibration and the reaction force at the same time while gripping the vibrating handle. In the study a device was developed to measure both the vibration and the force. The device consists of a measurement handle with four strain gauge and two accelerometers and a PC based control system with a program for the signal processing and evaluation of the hand-transmitted vibration and reaction force. The handle was installed on the vibration shaker so that it can move by the generated signal from the control system. As an application of the system dynamic reaction force and the frequency weighted acceleration at the handle attached to the shaker were measured at various grip force and feed force. This system will be very useful in the area of impedance measurement and the evaluation of performance of anti-vibration gloves.

  • PDF

Measurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with Sarcopenia

  • Ha, Yong-Chan;Yoo, Jun-Il;Park, Young-Jin;Lee, Chang Han;Park, Ki-Soo
    • Journal of Bone Metabolism
    • /
    • v.25 no.4
    • /
    • pp.243-249
    • /
    • 2018
  • Background: The aim of this study was to determine the accuracy and error range of hand grip strength measurement using various methods. Methods: Methods used for measurement of hand grip strength in 34 epidemiologic studies on sarcopenia were analyzed. Maximum grip strength was measured in a sitting position with the elbow flexed at 90 degrees, the shoulder in 0 degrees flexion, and the wrist in neutral position (0 degrees). Maximum grip strength in standing position was measured with the shoulder in 180 degrees flexion, the elbow fully extended, and the wrist in neutral position (0 degrees). Three measurements were taken on each side at 30 sec intervals. The uncertainty of measurement was calculated. Results: The combined uncertainty in sitting position on the right and left sides was 1.14% and 0.38%, respectively, and the combined uncertainty in standing position on the right and left sides was 0.35 and 1.20, respectively. The expanded uncertainty in sitting position on the right and left sides was 2.28 and 0.79, respectively, and the expanded uncertainty in standing position on the right and left sides was 0.71 and 2.41, respectively (k=2). Conclusions: Uncertainty of hand grip strength measurement was identified in this study, and a significant difference was observed between measurement. For more precise diagnosis of sarcopenia, dynamometers need to be corrected to overcome uncertainty.

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator (IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구)

  • Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Measurement and Analysis of Human Vibration (인체진동 측정 및 분석체계)

  • Park, Hui-Seok;Jang, Dong-Seong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.179-186
    • /
    • 1999
  • This article aims to provide information necessary for the measurement and analysis of human vibration, especially hand-arm vibration. The major health problems associated with the use of powered hand tools are the signs and symptoms of peripheral vascular and peripheral neural disorders of the fingers and hands. To prevent these problems, it is the first and the most important to measure the amount of the vibration transmitted to the upper extremities, and analyze its characteristics against the exposure limits such as ISO standards. In our country, however, very few studies have been done on the hand-arm vibration. One of the possible reasons might be lack of knowledge for the measurement and analysis schemes. The information introduced in this article would hopefully be of help for the upcoming studies.

  • PDF

The Database Development of 2-D Hands Measurement for Improving Fitness of gloves -focused on the ages from 18 to 64 of male & female adults- (장갑의 적합성 향상을 위한 손부위 2차원 계측정보 DB구축에 관한 연구 -성인 남.녀 만 18세에서 만 64세를 중심으로-)

  • 최혜선;김은경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.509-520
    • /
    • 2004
  • The aim of this study was to provide the basic 2-dimensional statistics requisite in the siting system and design of gloves. The 64 static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. Subjects were divided into four age groups: 18 to 29, 30 to 39, 40 to 49, and 50 to 64, and separated according to sex. Statistical tests such as Descriptive Analysis, and Anova were conducted to analyze the data and ascertain the differences among the ages. The disparities between sex groups were compared by T-test. In addition, correlation among the 57 measurements was analyzed and the results were compared to the data from Japanese and other studies. The results indicated that all the measurements were significantly larger in the male group. There were significant differences among age groups for most hand circumferences, breadths and thickness items. As the age increased, the hand circumferences, breadths and thickness items became wider and thicker. In addition, as the age increased, the mean measurement value of the length items decreased, so that it became shorter. Hand length was highly correlated with finger length, palm length and height. Maximum hand circumference II was highly correlated with hand circumferences, hand breadth and weight.

A Comparative Study on the Measurement of Korean Adult Hand for Glove Pattern-Making (장갑 설계를 위한 한국인 성인 남녀의 손 계측 비교)

  • Suh Mi-A;Ryu Kyung-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.6 s.53
    • /
    • pp.897-907
    • /
    • 2004
  • The aim of this study is provide fundamental data on the glove size and pattern-making. The study was conducted targeting 60 men and 271 women whose age were within the limits 18-35 in Seoul and the neighboring districts. A total of 90 features in the right hand wew used for the anthropometric measurement and analysis using anthropometry and photometry. The result show that there was a difference between men and women' hand. And the result of correlation analysis between hand factors, length factor related to length and depth factors, breadth factor related to breadth and circumference factors. The sailing glove size in Korea was not suitable to Index finger circumference at 1st Phalanx and Middle finger length.

  • PDF

Ergonomic Factors Assessment on Hand Tool Handle (수공구 손잡이의 인간공학적 요소 평가)

  • Yang Sung-Hwan;Cho Mun-Son;Kang Young-Sig
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • The goal of this study is to investigate the ergonomic factors in designing or selecting the hand tool handle. Electromyogram (EMG) were measured for various wrist postures and handle sizes under two loading conditions. Anthropometric data were measured and the correlation with EMG measurement data were analyzed. Investigations of this study show that wrist posture should be neutral for minimum muscle tension and optimum handle size can be found by measuring the EMG measurement data. It show that hand width and EMG measurement data is greatly correlated also. This study can be a guide of designing or selecting a hand tool, but further study with large sample sizes and various groups is needed for making general conclusion.

The Database Development of 2-D and 3-D Hands Measurement for Improving Fitness of Gloves - Focused on the Classification of Hand Type and Analysis of 3-D Hand Shape - (장갑의 적합성 향상을 위한 손부의 2차원 및 3차원 계측정보 DB구축에 관한 연구 -손의 유형분석 및 3차원 입체형상 분석을 중심으로-)

  • 최혜선;김은경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.910
    • /
    • pp.1300-1311
    • /
    • 2004
  • The aim of this study was to provide the 2 and 3 dimensional statistics requisite in the sizing system and design of gloves. The 64 2-dimensional static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. To summarize the information from the measurement values, a Factor Analysis and a Cluster Analysis among multivariate analyses were performed. 3-D scanner was used for visual results of hand shape of each cluster. The results were as follows. Twenty-two items were used for the factor and cluster analysis in order to classify the adult hand shape. The variable quantities that are explained by a total of 3 factors amounted to under 79.37% of the variable quantities. The definition results of the factors related to the hands are as follows: Factor 1 is the horizontal dimension, the thickness of hand factor; Factor 2 is the height of the crotch; and Factor 3 is the vertical dimension of the hand. The adults' group hand was divided into 2 clusters according to a cluster analysis using factor scores. The characteristics according to hand type were as follows: Cluster 1 referred to high horizontal dimensions and thickness, rather small vertical dimensions and crotch height; and Cluster 2 represented the rather smaller horizontal dimensions and thickness but longer hand length than Type 1. To provide specific shape data of each cluster, 3-D scanner measurement was performed. 3-dimensional data base was developed for each cluster type and visual information was provided.