• Title/Summary/Keyword: hand evaluation

Search Result 2,074, Processing Time 0.031 seconds

SC4/Trends in Standards and Regulations on Hand-arm Vibration (SC4/수완계 진동 측정 관련 규격 제정동향)

  • 장한기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.455-458
    • /
    • 2003
  • Effect of hand-transmitted vibration on human discomfort and health was reviewed. Since the effect by hand tool was more serious than those by any other vibration environments, western countries have protected hand tool workers by regulations. International organization for standardization legislate standard, ISO 5349, at 1979 for the measurement and evaluation of the effect. Afterwards, more than twenty standards on hand-arm vibration were enacted to protect any damage of hand tool users. Even though Korea Standards adopted ISO 5349 in 2001, it is required an action plan should be applied to all of work environments, especially to the workers using pneumatic tool workers such as miners, construction workers, and etc.

  • PDF

Comparison and Analysis on the Assessment Methods of Human Effects of Hand-arm Vibration (수완계 진동에 대한 인체 영향 평가 기법의 비교 분석)

  • 정완섭;권휴상
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1361-1364
    • /
    • 2001
  • The recent national contract (Ecotechnopia 21) supported by the ministry of environment puts much significance on new issues for the assessment of human effects arising from vibration and noise exposed to human. This paper focuses only on hand-arm vibration since it has been a major problem in protecting vibration exposure to human. To set up a systematic way of assessing adverse effects of hand-arm vibration, surveys were made on recent international standards and researches related to hand-arm vibration. The measurement and evaluation methods of hand-arm transmitted vibration, the relationship between vibration exposure and effects on health, and the assessment methods of nerve dysfunctions are addressed in this paper. Those methods are linked into a logical way of assessing effects of hand-arm vibration on human. Finally, the current activities and achievements in this work are briefly summarised.

  • PDF

Anslysis of tool grip tasks using a glove-based hand posture measurement system

  • Yun, Myung Hwan;Freivalds, Andris;Lee, Myun W.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.69-81
    • /
    • 1995
  • Few studies on the biomechanical analysis of hand postures and tool handling tasks exist because of the lack of appropriate measurement techniques for hand force. A measurement system for the finger forces and joint angles for the analysis of manual tool handling tasks was developed in this study. The measurement system consists of a force sensing glove made from twelve Force Sensitive Resistors and an angle-measuring glove (Cyberglove$^{TM}$, Virtual technologies) with eighteem joint angle sensors. A biomechanical model of the hand using the data from the measurement system was also developed. Systems of computerized procedures were implemented inte- grating the hand posture measurement system, biomechanical analysis system, and the task analysis system for manual tool handling tasks. The measurement system was useful in providing the hand force data needed for an existing task analysis system used in CTD risk evaluation. It is expected that the hand posture measurement developed in this study will provide an efficient and cost-effective solution to task analysis of manual tool handling tasks.s.

  • PDF

The Effects of Age, Gender, and Target Force Level on Controlled Force Exertion Tasks

  • Kong, Yong-Ku;Lee, Sung Yong;Kim, Dae-Min;Choi, Kyeong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.53-67
    • /
    • 2017
  • Objective: The purpose of this study is to build basic data to systematically develop a hand function evaluation tool by determining the effects of age, gender and target force level on the difference in hand function according to the target force level. Background: Precise and objective evaluation of hand functionality is a very important factor in quantifying treatment progress in patients or elderly people, and in verifying treatment effects. However, most hand function evaluations lack objectivity and accuracy, and therefore it is difficult to properly treat patients according to the given situation. Method: Sixteen healthy subjects (eight elderly and eight young people) participated in this study to evaluate the effects of age, gender, and target force level on tracking performance through rRMSE in terms of the tracking force and actual exerted force, by carrying out a task of maintaining six different target force levels for 20 seconds. Results: The result of this experiment indicated that elderly people and women had a lower ability to maintain a certain level of force than young people and men by 16% and 10%, respectively. The target force level results showed that the tracking error of the lowest force level (5% MVC) was significantly higher than that of 15% MVC, which in turn showed a higher tracking error than that of the higher target force levels. Conclusion: The results of this study can thus be utilized to develop a rehabilitation program for elderly people or other patients. Application: The authors expect that the results of the present study will be valuable to develop a rehabilitation program and hand function evaluation tool.

Clinical Evaluation of Pediatric Hand Injury (소아의 수부손상에 대한 임상적 고찰)

  • Kim, Jeong-Jin;Kim, Jeong-Cheol;Suh, Dong-Bo;Choi, See-Ho;Seul, Jung-Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.202-208
    • /
    • 1991
  • Hand injury in children was increased due to multiple environmental risks and failed attention of parents to children in rapidly developing society. By the results of this evaluation in 37 cases, it was summarized as follows. First, hand injuries in children most commonly occurs in spring, and occurs more commonly in the children at the age of high activity. The most common level of injury is zone I by microreplantation zone, and zone II by tendon injury zone. The more desirable results were obtained by full thickness skin graft and composite graft if it were possible. For the better functional results compare to adults, the methods and procedures must be constructed after more evaluation with more clinical cases. In the cases of pediatric hand injury, the most important fact is prevention of injury, with the close attention by parents, and the second is appropriate diganosis and treatment for more functional results.

  • PDF

Field Application and Evaluation of the ACGIH Hand Activity Level TLV® (ACGIH Hand Activity Level TLV®의 현장 적용 및 평가)

  • Kim, Boo Wook;Woo, Ji Hoon;Kang, Dongmug;Shin, Yong Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.81-90
    • /
    • 2006
  • The Strain Index(SI) has been commonly used to evaluate the musculoskeletal disorders(MSDs) of upper extremities. Recently, the American Conference of Governmental Industrial Hygienists(ACGIH) adopted the Threshold Limit Value for hand activity level (HAL TLV) focused on the hand, wrist, and forearm. The MSDs risks of 37 repetitive works conducted at an automobile climate control system manufacturing factory were evaluated using both the HAL TLV and the SI, and the results by two methods were compared. Also, measured repetitive frequencies of upper limbs joint were mesured using electromyogram and electrogoniometer. The evaluation results of the HAL were related with the repetitive frequency data of upper limbs joint by electrogoniometer, and the NPF was related with %MVC of ECU. The evaluation result of HAL TLV was highly related with the SI score(r=0.66, p<0.01). Of total 37 tasks, 25 tasks(67.6%) were exceeded the TLV and 34 tasks(91.9%) exceeded the SI limit. Although there was a high relationship between the HAL TLV and SI score, the HAL TLV underestimated the risk in comparison with the SI. The correlation coefficients(r) between the HAL TLV data and the repetitive frequency of upper limbs joint were 0.45~0.55(p<0.01). The MSD symptoms was significantly different between high risk groups and low risk groups evaluated by HAL TLV(p<0.01), but was not different between two groups by SI. In conclusion, the HAL TLV is a proper tool for repetitive works.

The Peculiarities of New Textile Hand Evaluation Method

  • Eugenija, Strazdiene;Matas, Gutauskas
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.414-419
    • /
    • 2006
  • The paper presents information concerning metrological and technical characteristics of KTU-Griff-Tester device, the optimization of its parameters and the cases of its application. It was defined that the behaviour of textile material during its extraction through a rounded hole depends upon its structure. Variations of geometrical shape of woven and knitted specimens can be described by mathematical expressions of shortened epicycloids and Cassini ovals. It is shown that waving process of disc shaped specimen can be predicted on the basis of the law of sine curve. The examples of textiles treatment with different types of commercial softeners are presented, herewith showing the suitability (sensitiveness) of the new device to detect the changes of textile hand. Meantime it is shown that the level of materials anisotropy can be decided on the basis of transformations of specimen's geometrical shape.

Ergonomic Design of Magic Saw Handle

  • Jung, Kwang-Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.469-474
    • /
    • 2012
  • The aim of this study is to develop an ergonomic design of magic saw handle considering user experiences. Background: Frequent use of hand tool can cause musculoskeletal disorders by inadequate wrist posture, excessive strength, repetitiveness, friction and pressure, vibration, etc. A hand tool that is inappropriately designed has higher risk causing musculoskeletal disorders. Complaints for the design of magic saw handle has been raised by many users according to the increasing use of magic saw. Method: Hand tool has to be designed considering worker's characteristics and task condition to prevent worker's musculoskeletal disorders. For this, user experiences for magic saw handle were measured through questionnaire survey and observation. Results: An ergonomic design of magic saw handle considering user experiences was proposed and then its design suitability was evaluated in comparison with the existing handle design using EMG and subjective evaluation. Conclusion: The proposed handle design showed higher satisfaction and lower muscular fatigue. Application: The results of this study can be effectively used to develop a new magic saw.

Improvement of an Underactuated Prosthetic Hand Based on Grasp Performance Evaluation (파지성능 평가에 기반한 의수용 핸드의 설계 개선)

  • Lee, Geon Ho;Kwon, Hyo Chan;Kim, Kwon Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.10
    • /
    • pp.843-849
    • /
    • 2016
  • It has been shown that the adaptive grasp feature can be implemented by underactuated robotic hands with a minimal number of actuators. Following this approach, a new design of prosthetic hand is presented. A method is proposed for evaluating grasp performance using cylinders, spheres, and square bars of various sizes. The effects of the major design parameters were investigated experimentally and an improved design is proposed.

Blending Effect on the Mechanical and Hand Properties of Wool/Acrylic Blend Knits

  • Park Myung-Ja
    • The International Journal of Costume Culture
    • /
    • v.8 no.1
    • /
    • pp.23-31
    • /
    • 2005
  • Mechanical properties and hand evaluation of wool/acrylic(W/A) blend knits were conducted before and after repeated washing to get the optimum W/A blending ratio, which could help achieve the optimum mechanical and hand properties of the knits. The five test fabrics using the yarns with different W/A blending ratios($\%$), 100/0, 70/30, 50/50, 30/70, 0/100, were knitted. The fabrics were washed by a rotating drum type washing machine. Then, objective mechanical and hand properties were evaluated by KES-FB, Kawabata evalution system for fabric. The results are as follows: there was no change in the hand value of the knitted fabric with the W/A-blended yarn caused by the change in the blending ratio before washing. After washing, however, the increase of acrylic's blending rate caused the bending property to decrease proportionally, while the friction coefficient of the surface property increased. Furthermore, the study showed that W/A 50/50 possesses the most superior tensile property and shearing property, which could attain the optimum blending ratio. Similar results in hand value were derived in all the samples. After washing, however, the increase in acrylic's blending rate caused a proportional decrease in KOSHI and an increase in FUKURAMI. In addition, W/A 50/50 gained the biggest NUMERI value, again corresponding to the optimum blending ratio. Similar results in total hand value were derived in all the samples before washing. After washing, though, all the total hand values decreased, and, as the wool fabric's blending rate increased, the total hand values proportionally decreased further.

  • PDF