• Title/Summary/Keyword: hand evaluation

Search Result 2,080, Processing Time 0.026 seconds

Analysis of Accuracy and Reliability for OWAS, RULA, and REBA to Assess Risk Factors of Work-related Musculoskeletal Disorders (근골격계질환 유해요인 정밀조사를 위한 OWAS, RULA, REBA의 평가 정확도 및 신뢰도 분석)

  • Cheon, Woohyun;Jung, Kihyo
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.31-38
    • /
    • 2020
  • The study evaluated the accuracy and intra-rater reliability for OWAS (Ovako Working posture Analysing System), RULA (Rapid Upper Limb Assessment), REBA (Rapid Entire Body Assessment) to improve their evaluation accuracy and reliability. Participants (n = 163) with undergraduate degree were recruited in this study and trained for 6 hours about the ergonomic assessment methods. Ergonomic assessments were conducted using OWAS, RULA, and REBA for a representative work with dynamic posture found in manufacturing industries. The study compared action categories (overall level) and detailed evaluation scores for individual body part. Action categories of the participants significantly differed from the golden reference defined by ergonomic experts. The participants underrated or omitted scores for truck (37.4% of the participants) and legs (52.8%) in OWAS. Similarly, the participants underrated or omitted additional scores for all body parts except the hand and wrist in RULA (53.5%) and REBA (54.8%). On the other hand, the participants overrated scores for the hand and wrist in RULA (55.2%) and REBA (39.9%). The results found in this study can help of selecting focus points and parts during assessment and education to improve accuracy and reliability of the ergonomic assessment methods.

The Effect of Using Therapeutic Instrumental Music Performance (TIMP) in Uninvolved Hand Function for Children with Spastic Cerebral Palsy (치료적 악기 연주 적용이 경직형 뇌성마비 아동의 우세손기능에 미치는 효과)

  • Han, Song Yi
    • Journal of Music and Human Behavior
    • /
    • v.8 no.1
    • /
    • pp.1-16
    • /
    • 2011
  • This study was to investigate the influence of using Therapeutic Instrumental Music Performance (TIMP) in uninvolved hand function for children with spastic cerebral palsy. Participants were recruited from a welfare center for people with cerebral palsy(CP). Ages ranged from 11 to 12, and a total of 15 TIMP sessions were provided for 3 weeks. Hand function tests were used including Jebsen Hand Function Test for hand function, Box and Block Test for dexterity of uninvolved hand, and MIDI (Musical Instrument Digital Interface) evaluation for velocity of fingers. The TIMP program consisted of hand percussion playing and keyboard playing with changes of timbre and tempo. While the scores of Jebsen test and Box and Block test were improved for all participants, outcomes of MIDI analysis showed differences among participants. Overall, hand function improvements were observed after the completion of using the TIMP program, and the results implies that the TIMP program can be applied in upper extremity rehabilitation for children with CP.

Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

  • Dong, Ren G.;Sinsel, Erik W.;Welcome, Daniel E.;Warren, Christopher;Xu, Xueyan S.;McDowell, Thomas W.;Wu, John Z.
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.159-173
    • /
    • 2015
  • The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

기술혁신 지향적 정부구매제도의 정책방향

  • 김태황;송종국
    • Proceedings of the Technology Innovation Conference
    • /
    • 2000.06a
    • /
    • pp.123-151
    • /
    • 2000
  • The aim of this paper is to investigate how the public procurement policy exerts an effect upon the technology innovation of the firm and to make alternative proposals how to reinforce the effect. Although the pubic procurement process based on its monopsonic idiosyncrasy implies the means to lead the firms' supply function, the present system has contributed a little to accelerate the technology innovation. In fact, the system is lacking of the evaluation capability referring to the technological computer among the bidding films. So as to reinforce the function of technology innovation of the public procurement policy, it is necessary to improve the procurement institutions, in particular bidding and contract system. Finally, the paper propose, on the on hand, to enlarge the application range of the total bidding system in order to apply more strictly the technology evaluation standards on bidding, and on the other hand, to multiply the competitive proposal and the incentive contract type.

  • PDF

Bilateral Type III Postaxial Polydactyly: A Case Report (양측성 축뒤손가락과다증의 치험례)

  • Jo, Yong Woo;Lim, So Young;Mun, Goo Hyun;Hyon, Won Sok;Bang, Sa Ik;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.773-776
    • /
    • 2005
  • An unusual case is presented as bilateral, complete digital duplication of the hand in a 32-year-old man. Radiographic evaluation showed complete duplication of intact phalanges and metacarpal bones in both hands. Although polydactyly of the hand is reported to occur among approximately 1 in 1000 live births, most of these malformations are rudimentary skin tags. Complete postaxial polydactyly is uncommon; it occurs in approximately 0.014% of all live births. The main goal of the surgical treatment is to establish adequate function and appearance. This case reports the preoperative evaluation and management of bilateral postaxial type III duplication of the fingers.

Study on the Evaluation of D.P. and Handle for Vapor Phase Finished Fabrics (V.P.가공 직물의 D.P.성과 Handle 평가에 관한 연구)

  • 최근영;백천의
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.5
    • /
    • pp.792-800
    • /
    • 1996
  • The shape retention finishing provides a fabric for easiness of no-ironing after laundering. In spite of the obvious importance of the new finishing treatment, few systematic studies have been performed on the handle of the fabrics finished by the durable press process. The purpose of this research is to investigate the relationships among the mechanical properties, durable press conditions, primary hand values and the total hand value of the fabrics finished by shape retention process. In this experiment, durable press grade of unfinished fabrics decreased below 2.5, but those of finished fabrics maintained above 4, but the mechanical properties of finished fabrics did not change significantly after laundering. In finished fabrics, D.P. value were correlated with mechanical properties, but had little effects with H.V. and T.H.V. Since the evaluation of the effect of durable press process was done with the naked eyes and standard sample, we could not know exactly change o( mechanical properties, but trace the change of mechanical properties which gave influences on the durable press effects by using KES-FB System.

  • PDF

Ergonomic Evaluation and Improvement of the Manufacturing Lines of Compressors (컴프레서 제조공정의 인간공학적 개선에 관한 연구)

  • Bae, Dong-Cheol;Chang, Seong-Rok
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.148-152
    • /
    • 2005
  • The purpose of this paper is to investigate risk factors and ergonomically improve the manufacturing lines of compressors for prevention of work-related musculoskeletal disorders, enhancement of productivity, and workers satisfaction We executed questionnaire survey, ergonomic risk factors investigation of manufacturing lines and ergonomic intervention of work methods, workplace and hand tools. The results of the questionnaire showed that $7.9\%$ of respondents were positive in WMSDs symptom survey. In ergonomic evaluation, the analysis methods such as RULA and NIOSH lifting equation were used and 28 processes in the lines were evaluated to be potentially hazardous. We ergonomically improved the processes to reduce potential WMSDs hazards : manual material handling, carts, work tables, transport methods, working posture and hand tools.

A Development of Working Adaptation Evaluation System using Finger Force Measurement (지력측정을 이용한 작업 적합성 평가 시스템개발)

  • Byeon, M.K.;Hur, Woong;Han, S.C.;Kim, J.K.
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.05a
    • /
    • pp.31-36
    • /
    • 2002
  • In this paper, we developed a working adaptation evaluation system using finger force measurement which interact between material and biological system. The system consists of a finger force transducer, a signal conditioner, an A/D converter, a computer, and a software system for data processing. The finger force transducer is made by a load cell and a special mechanism. The data processing software controls the A/D converter, data monitoring, and data analysis for group classification. The developed system were tested by 4 different materials in left hand and the finger forte transducer in the other hand's thumb and index finger with 16 persons. As the results of experiments, the developed system could measure the finger force quantitatively and classify the measured values into four groups.

  • PDF

Analysis of Physical/Mechanical Properties and Color of Bast Fiber Fabrics Dyed using Rubia akane Nakai

  • Jang, Yoon-Young;Kim, Jong-Jun
    • Journal of Fashion Business
    • /
    • v.13 no.3
    • /
    • pp.86-98
    • /
    • 2009
  • The fashion industry saw the emergence of environment-friendly and natural fabric materials recently. The naturalism trend has established sectors in the textile and fashion industry also. Ramie and hemp have long been favored fabric materials in Korea especially for summer. The hand-related mechanical/physical properties of the fabric specimens were analyzed using a fabric objective measurement system, KES(Kawabata Evaluation System). Subjective evaluation was also implemented based on a series of selected adjectives. Studies on natural dyeing methods are important since the establishment of scientific approach is needed in terms of environment and human safety along with the reproduction of traditional natural dyeing methods. In this study, linen, ramie, hemp, and cotton/polyester/linen union fabric specimens were used for the natural dyeing using Rubia akane Nakai with the mordant of gallnut. ${\Delta}E$ values of dyed fabric specimens, mordanted and dyed once using Rubia akane Nakai, increased significantly compared to those of repeatedly dyed fabric specimens without mordanting.

Response Characteristics of Human by Whole-body Vibration and Hand-arm Vibration (전신진동과 부분진동에 대한 인간의 응답특성)

  • 장호경
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.77-85
    • /
    • 1994
  • In this paper, the vibration response characteristics of individual's subjective are studied to whole-body and hand-arm induced vibration. For defining limits of vibration exposure to human, experimental data are investigated in a set of vibration criteria specified in ISO Standard 2631. Instrumentation requirements for evaluation of the responses of humans to vibration according to these criteria are discribed.

  • PDF