• 제목/요약/키워드: hand condensation

검색결과 59건 처리시간 0.019초

Deformable Template과 Condensation을 이용한 손 영역 분류와 추적 (Classification and Tracking of Hand Region Using Deformable Template and Condensation)

  • 정현석;주영훈
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1477-1481
    • /
    • 2010
  • In this paper, we propose the classification and tracking method of the hand region using deformable template and condensation. To do this, first, we extract the hand region by using the fuzzy color filter and HCbCr color model. Second, we extract the edge of hand by applying the Canny edge algorithm. Third, we find the first template by calculating the conditional probability between the extracted edge and the model edge. If the accurate template of the first object is decided, the condensation algorithm tries to track it. Finally, we demonstrate the effectiveness and feasibility of the proposed method through some experiments.

CFD와 TDR을 이용한 고층 공동주택의 결로 판정 도구 개발 (Development of Analytical Tool for Checking Condensation of High-Rise Apartment Using CFD & TDR)

  • 방승기;김철현
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.15-24
    • /
    • 2013
  • On this Thesis, We conduct a research of curtain wall high-rise apartment located in Songdo for preparing a simple method to check possibility of condensation on each part of curtain wall using only indoor temperature, humidity and outdoor temperature. According to CFD analysis result, condensation occurred if indoor environment did not ventilated. On the other hand, in case of ventilation on indoor environment, condensation did not appear; so I could find ventilation prevent surface condensation on inside surface of curtain wall. Moreover, when temperature of the floor is higher, condensation is decrease more than lower floor temperature.

모조 근관의 크기와 충전 방법이 orthograde MTA apical plug의 미세누출에 미치는 영향 (EFFECTS OF CONDENSATION TECHNIQUES AND CANAL SIZES ON THE MICROLEAKAGE OF ORTHOGRADE MTA APICAL PLUG IN SIMULATED CANALS)

  • 남득림;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제34권3호
    • /
    • pp.208-214
    • /
    • 2009
  • 이 연구의 목적은 서로 다른 두 개의 근관 크기(#70, #120)를 가진 레진 모형에 MTA (minoral trioxide aggregate)를 서로 다른 두 가지 방법 (수기구 충전(HC), 초음파 보조 수기구 충전(UAHC))으로 정방위 충전하고 MTA apical plug의 미세 누출을 평가하는 것이다. 직선형 근관 형태를 가지며, #70과 #120의 치근단 크기를 갖는 레진 모형을 각각 30개씩 준비하였다. 이 시편들을 MTA의 적용 방법에 따라 각 군을 2개의 아군으로 다음과 같이 분류하였다 (n=15); C70: HC + 치근단 크기 #70, C120: HC + 치근단 크기 #120, U70: UAHC + 치근단 크기 #70, U120: UAHC + 치근단 크기 #120. MTA 충전을 완료한 후에, 24시간 동안 실온에서 100% 습도를 유지하여 경화시켰다. 근관의 상부는 열연화 충전 시스템(Obtura II)을 이용하여 충전하였다. 48시간 동안 100% 습도를 유지하여 실온에서 0.2% rhodamine B 용액을 이용해 미세누출 실험을 하였다. 이 연구결과 #70의 치근단 크기를 갖는 그룹 사이에서 UAHC가 HC에 비해 미세누출이 적은 것으로 나타났다(p<0.05). 이 연구 조건하에서는 초음파 진동을 동반한 정방위 MTA apical plug 형성 방법이, 특히 좁은 근관에서 더 효율적인 것으로 사료된다.

Condensation Heat Transfer of R22, R407C, and R410A in Slit Fin-and-Tube Heat Exchanger

  • Jeon, Chang-Duk;Lee, Jin-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.188-198
    • /
    • 2003
  • R410A and R407C are considered to be alternative refrigerants of R22 for the air-conditioners. An experimental study is carried out to investigate the effect of the change of mass flow rate on the characteristics of heat transfer and pressure drop in three row slit finned-tube heat exchanger for R407C, R410A and R22. R407C, a non-azeotropic refrigerant mixture, exhibited a quite different condensation phenomenon from those of R22 and R410A and its condensation heat transfer coefficient was much lower than that of R22 and R410A. On the other hand, the condensation heat transfer coefficient of R410A, near-azeotropic refrigerant mixture, was a little higher than that of R22. R410A also showed the lowest condensation pressure drop across the test section. For all refrigerants, the condensation heat transfer coefficient and pressure drop increase as the mass flux increases. The condensation heat transfer coefficient correlation proposed by Kedzierski shows the best agreement with the experimental data within $\pm$20%.

응축충격파와 경계층 간섭의 피동제어(II) (A Passive Control of Interaction of Condensation Shock Wave anc Boundary Layer(II))

  • 최영상;권순범;김병지
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.329-340
    • /
    • 1997
  • A passive control of interaction of condensation shock wave / boundary layer for reducing the strength of condensation shock was conducted experimentally in a 2.5 * 8 cm$^{2}$ indraft type supersonic wind tunnel. The effects of following factors on passive control were investigated: 1) the thickness of porous wall, 2) the diameter of porous hole, and 3) the orientation of porous hole. On the other hand, the location of nonequilibrium condensation region and condensation shock wave was controlled by regulation of the stagnation conditions. Surface static pressure measurements as well as Schlieren observations of the flow field were obtained, and their effects were compared with the results the cases of without passive control. It was found that thinner porous wall, smaller porous hole and FFH orientation for the same cavity size and porosity of 12% are more favourable than the cases of its opposite.

순수냉매의 흐름응축 열전달계수 (Flow Condensation Heat Transfer Coefficients of Pure Refrigerants)

  • 김신종;송길홍;정동수
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.175-183
    • /
    • 2002
  • Flow Condensation heat transfer coefficients (HTCs) of Rl2, R22, R32, Rl23, Rl25, R134a, R142b were measured experimentally on a horizontal plain tube. The experi- mental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water-glycol loop. The test section in a refrigerant loop was made of a copper tube of 8.8 mm inner diameter and 1000 mm length respectively. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. All tests were performed at a filed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, 300 kg/$m^2$s. The experimental result showed that flow condensation HTCs increase as the quality, mass flux, and latent heat of condensation increase. At the same mass flux, the HTCs of R32 and R142b were higher than those of R22 by 35~45% and 7~14% respectively while HTCs of R134a and Rl23 were similar to those of R22. On the other hand, HTCs of Rl25 and Rl2 were lower than those of R22 by 28 ~30% and 15 ~25% respectively Finally, a new correlation for flow condensation HTCs was developed by modifying Dobson and Chato's correlation with the latent heat of condensation considered. The correlaton showed an average deviation of 13.1% for all pure fluids data indicating an excellent agreement.

실시간 객체 추적을 위한 Condensation 알고리즘과 Mean-shift 알고리즘의 결합 (Integration of Condensation and Mean-shift algorithms for real-time object tracking)

  • 조상현;강행봉
    • 정보처리학회논문지B
    • /
    • 제12B권3호
    • /
    • pp.273-282
    • /
    • 2005
  • 실시간 객체 추적(Real-time object tracking)은 비디오 감시 시스템, 비전 기반 네비게이터와 같은 비전 응용 산업이 발달하면서 그 중요성이 더해지고 있는 분야이다. 객체 추적을 위해 많이 이용되고 있는 알고리즘으로 Mean-shift와 Condensation 알고리즘이 있다. Mean-shift 알고리즘을 기반으로 한 객체 추적 알고리즘은 구현이 간단하고, 적은 계산 복잡도를 갖는 장점이 있다. 따라서 실시간 객체 추적 시스템에 적합하다고 할 수 있지만, 지역 모드(Local mode)로 수렴하는 특성으로 인해 복잡한 환경(Cluttered environment)에서는 좋은 성능을 나타내지 못하는 단점을 가지고 있다. 반면, 여러 개의 후보들을 이용해 객체의 위치를 추정하는 Condensation 추적 알고리즘은 복잡한 환경에서 특정 객체를 추적하는데 많이 사용된다. 하지만 Condensation 알고리즘을 기반으로 한 추적 알고리즘은 정확한 추적을 하기 위해서 복잡도가 높은 객체 모델과 많은 수의 후보가 요구된다. 따라서 높은 복잡도를 갖게 되고, 이것으로 인해 복잡한 환경에서는 실시간 구현이 어렵다는 단점을 갖게 된다. 본 논문에서는, 복잡한 환경에서 실시간 객체 추적에 적합하도록 Condensation 알고리즘과 Mean-shift 알고리즘을 결합해서, 적은 수의 후보들을 이용하는 모델을 제안한다. 적은 수의 후보들을 이용하더라도, Mean-shift 알고리즘을 이용해 보다 높은 유사도를 가지는 후보들만을 이용함으로써, Condensation 알고리즘이나 Mean-shift 알고리즘만을 이용할 때보다 더 나은 성능을 얻을 수 있었다.

내경 6 mm 평관과 마이크로 핀관 내에서 R22 대체냉매의 흐름응축 열전달계수 (Flow Condensation Heat Transfer Coefficients of R22 Alternative Refrigerants in Plain and Microfin Tubes of 6.0 mm Inside Diameter)

  • 박기호;서영호;박기정;정동수
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.444-451
    • /
    • 2004
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 6.0∼6.16 mm inside diameter and 1.0 m length. Refrigerants were cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/m2s. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 4∼16% and 16∼42% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 3∼9% for a microfin tube. Heat transfer enhancement factors of a microfin tube were 1.3∼1.9.

Protein Kinase $C\alpha$ Is Involved in the Cell Condensation During Chondrogenesis in Vitro

  • Lim, Young-Bin;Kang, Shin-Sung;Lee, young-Sup;Sonn, Jong-Kyung
    • Animal cells and systems
    • /
    • 제4권4호
    • /
    • pp.361-366
    • /
    • 2000
  • In order to investigate the role of protein kinase C (PKC) in chondrogenic differentiation, we examined the localization of PKC isoforms in a limb bud micromass culture system. PKC$\alpha$ is specifically localized in the regions which would become cartilage nodules, while PKC$\lambda/l$ and $\zeta$ display widespread distribution in the whole culture. Distribution of PKC$\alpha$ change along with promotion or inhibition of chondrogenesis by lysophosphatidylcholine or phorbol 12-myristate 13-acetate. On the other hand, localization of PKC$\lambda/l$ or $\zeta$ a was not changed by the modulation of chondrogenesis. Peanut agglutinin binding protein which is associated with cell aggregation during chondrogenesis was present in the cell condensation regions and its expression in those regions was influenced by PKC activity. Expression of fibronectin and N-cadherin in the cell condensing area were also affected by modulation of PKC activity. These results suggest involvement of PKC$\alpha$ in the cell condensation, possibly through regulating expression of fibronectin and N-cadherin.

  • PDF

Assessment of CUPID code used for condensation heat transfer analysis under steam-air mixture conditions

  • Ji-Hwan Hwang;Jungjin Bang;Dong-Wook Jerng
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1400-1409
    • /
    • 2023
  • In this study, three condensation models of the CUPID code, i.e., the resolved boundary layer approach (RBLA), heat and mass transfer analogy (HMTA) model, and an empirical correlation, were tested and validated against the COPAIN and CAU tests. An improvement on HMTA model was also made to use well-known heat transfer correlations and to take geometrical effect into consideration. The RBLA was a best option for simulating the COPAIN test, having mean relative error (MRE) about 0.072, followed by the modified HMTA model (MRE about 0.18). On the other hand, benchmark against CAU test (under natural convection and occurred on a slender tube) indicated that the modified HMTA model had better accuracy (MRE about 0.149) than the RBLA (MRE about 0.314). The HMTA model with wall function and the empirical correlation underestimated significantly, having MRE about 0.787 and 0.55 respectively. When using the HMTA model, consideration of geometrical effect such as tube curvature was essential; ignoring such effect leads to significant underestimation. The HMTA and the empirical correlation required significantly less computational resources than the RBLA model. Considering that the HMTA model was reasonable accurate, it may be preferable for large-scale simulations of containment.