• 제목/요약/키워드: hand circumference

검색결과 110건 처리시간 0.021초

한국인을 위한 장갑 패턴 고찰 (2) - 장갑 원형 설계를 중심으로 - (A Study on the Pattern-making for Korean Glove - Focusing on Pattern-making for Glove -)

  • 류경옥
    • 복식문화연구
    • /
    • 제17권6호
    • /
    • pp.981-991
    • /
    • 2009
  • The purpose of this study was to develop the pattern-making for Korean glove. To develop the pattern-making for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over th 15 years) were interviewed on the method of glove. The results of regression analysis(hand data) were as follows (unit: cm): wrist thumb tip length = middle finger length + 3.22, hand bread = 1.25 $\times$ middle finger length + 2.18, middle finger breadth at dist = 0.23 $\times$ index finger circumference + 0.4, maximum hand circumference = 3.15 $\times$ index finger circumference + 4.13, middle finger circumference = 0.91 $\times$ index finger circumference + 0.47, maximum hand thickness = 0.69 $\times$ index finger circumference -0.02. Hand measurements for glove pattern-making were developed: There were palmar hand length, hand circumference, index finger circumference and middle finger length.

  • PDF

손기능과 손의 특성과의 관계 (The Relationships between Hand Function and Characteristics of Hand)

  • 이선명
    • 한국임상보건과학회지
    • /
    • 제3권3호
    • /
    • pp.409-418
    • /
    • 2015
  • Purpose. This study was to investigate the relationship between hand function and characteristics of hand. Methods. Participants were 56 occupational therapy students who studied in M colleges in Gyengsangnam-do, april 20, 2015 from 1 May, and hand circumference and length (vertical, w), the width was measured. A hand grip on the measurement subject was measured by the Grip dynamometer and Pinch gauge. Results. The results was hand length, width, circumference long, broad, thick, and hand strength was a greater correlation emerged. Grip strength was showed a significant correlation to the size and grip strength was also correlated. Conclusion. This study was correlation of length of the hand, a length wide and strength of the finger circumference.

소방공무원의 장갑제작을 위한 손 치수 연구 (Hand Sizing Study for Development of Firefighting Gloves)

  • 권채령;장미나;정다운;김동은
    • 한국의류학회지
    • /
    • 제43권3호
    • /
    • pp.416-426
    • /
    • 2019
  • This study measured and analyzed male firefighters hand sizes as well as suggested data for developing firefighting gloves with a good fit. Accordingly, body dimensions related to the hand were measured for 100 male firefighters. Twenty-three measuring items related to the hand and lower arm were selected. The firefighters' measurement data were compared to general adult male measurements from the 6th Korean Anthropometric data to analyze the hand sizes characteristics of firefighters. As a result, height, hand circumference, hand breadth, wrist circumference, elbow-wrist length, forearm-fingertip length and firefighter weight were significantly larger than adult males. A correlation analysis for 23 items was conducted to select items used as standards for setting a size when manufacturing firefighting gloves. Hand length and circumference were selected as representative hand parts for making firefighting gloves. Cross analysis between hand length and circumference were conducted to find the section showing the highest distribution ratio. As a result, the highest sections were between 19cm and 21cm for hand circumference and between 18.5cm and 19.5cm for hand length, which may be suggested as the most important ranges.

장갑치수적합성 향상을 위한 기본치수 및 참고치수 설정 (Development of the Standard Size Dimensions and Reference Sizes for Improving Size Suitability of Gloves)

  • 김은경
    • 한국의류산업학회지
    • /
    • 제10권6호
    • /
    • pp.966-978
    • /
    • 2008
  • The aim of this study was to provide size intervals in hand requisite in design of gloves. In this study, a survey was administered to gather information about glove manufacturers' sizing systems. In addition, KS glove standards' size dimensions were analyzed. As well, the ISO hand sizing system was also studied. Based on all the analyses' results, a new glove size intervals were composed. The size comprised the control dimensions of hand length and hand circumference. The size interval was 8mm in hand length and 13mm in hand circumference. The size range was established by making the coverage above 80%. The coverage of the new size interval system for an adult's hand was 86.4% and 13 sizes were suggested. The coverage of the male size system was 86.0% and 10 sizes were suggested. The coverage of the female size system was 87.6% and 8 sizes were suggested. For the unfitted gloves, size ranges based on hand length and hand circumference were developed. For the adults group, S, M, L, and XL were suggested and the coverage of the new size range was 78.8%. For the male group, S, M, and L were suggested and the coverage was 82.3%. For the female group, S, M, and L were also suggested and the coverage was 81.3%.

3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구 (Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating)

  • 권석동;설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

경락마사지가 편마비 환자의 손부종과 손기능에 미치는 효과 (The Effect of the Meridian Massage on the Hand Edema and Function of the Hemiplegic Patient)

  • 이상은;이향련
    • 성인간호학회지
    • /
    • 제15권4호
    • /
    • pp.520-530
    • /
    • 2003
  • Purpose: The objective of the study was to identify the effects of the meridian massage therapy on hand edema and hand functions in patients with hemiplegia. Method: The experiment was conducted in the Oriental Medical ward of "K" hospital during the period of 2000. 12. 15 - 2001. 03. 15. Fifty five subjects with hemiplegia following a stroke participated in the study. Volumetric size of the hand and the circumference of the index finger of each patient was measured and functional points were recorded for pre and post experiment. Result: 1. Apparent decrease in volumetric size of the hand and the circumference of the index finger(p=.022. p=.021), and higher functional points(p=.003) in the experimental group in comparison to the control group. 2.Volume of hands & their functions appeared to be irrelevant(r=-.195, p=.154). 3. Circumference of the index finger & their functions also turned out to be irrelevant (r=-.110, p=.424). Conclusion: Meridian massage is an effective nursing interventional therapy to relieve hand edema and improve hand functions in hemiplegic patients and has great potential for use in a wide range of medical fields as an efficient supplementary treatment for stroke rehabilitation.

  • PDF

장갑의 치수규격 실태에 관한 연구 - KS와 ISO 치수체계를 중심으로 - (A Study on Actual Conditions of Glove Size Standards - Focused on KS and ISO Sizing System-)

  • 김은경;최혜선
    • 복식
    • /
    • 제54권6호
    • /
    • pp.77-90
    • /
    • 2004
  • The purpose of this study was to provide basic information requisite in the new sizing system for gloves. KS glove standards' size dimensions, size designation and labeling systems were analyzed. Also, KS glove standards' control sizes were compared to the anthropometric data of 824 Korean adults taken in the previous study. As well, the ISO hand size system was also compared to the anthropometric data of the previous study according to frequency tables of hand length and hand circumference. The size dimensions showed differences among KS standards and there was no size designation and labeling systems existed in KS standards. Among KS glove size systems, protective rubber gloves for radioactive contamination and surgical rubber gloves' size which followed ISO system were accurately indicate the hand size of the person a glove is intended to fit. ISO glove sizing system comprised the control dimensions of hand length and hand circumference. The coverage of ISO size A was 84.8% which was highest among ISO size A. B, C. And in hand circumference 178, 191, 203, 216mm showed the frequencies above 3% and in hand length 167, 175. 183, 191, 199mm showed the frequencies above 3%.

장갑 설계를 위한 한국인 성인 남녀의 손 계측 비교 (A Comparative Study on the Measurement of Korean Adult Hand for Glove Pattern-Making)

  • 서미아;류경옥
    • 복식문화연구
    • /
    • 제12권6호
    • /
    • pp.897-907
    • /
    • 2004
  • The aim of this study is provide fundamental data on the glove size and pattern-making. The study was conducted targeting 60 men and 271 women whose age were within the limits 18-35 in Seoul and the neighboring districts. A total of 90 features in the right hand wew used for the anthropometric measurement and analysis using anthropometry and photometry. The result show that there was a difference between men and women' hand. And the result of correlation analysis between hand factors, length factor related to length and depth factors, breadth factor related to breadth and circumference factors. The sailing glove size in Korea was not suitable to Index finger circumference at 1st Phalanx and Middle finger length.

  • PDF

한국인을 위한 장갑 패턴 고찰 (1) - 업체 조사를 통한 손계측 항목을 중심으로 - (A Study on the Measurement of Korean Hand - Focusing on Glove & Hand Dimension -)

  • 류경옥
    • 복식문화연구
    • /
    • 제17권5호
    • /
    • pp.866-877
    • /
    • 2009
  • The purpose of this study was to develop the dimension of hand pattern-making for Korean glove. The glove pattern-making has difficult problem in combination of anthropometric and engineering aspects. In addition, existing dimension data are not enough for glove pattern-making. Therefore, to develop the dimension for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over the 15 years) were interviewed on the method of glove. The result of comparing between the structures in hand and existing glove pattern, there draw deduction from follows. Pattern-making for glove need size of hand length, thumb length, index finger length, middle finger length, ring finger length, hand circumference, thumb-ring finger circumference and maximum hand thickness.

  • PDF

한국과 중국 여성의 체형특성과 체지방에 관한 연구 (The Studies of Body Fat and Physical Characteristics between Korean and Chinese Females)

  • 성민정
    • 한국의류산업학회지
    • /
    • 제8권6호
    • /
    • pp.697-701
    • /
    • 2006
  • The physical traits and the body fat rate of women in 20s~30s in China and Korea, which are very adjacent to each other but different, were compared and examined. By this research, the physical type of women in both countries were examined, and the result was as follows. As Chinese women in 20s~30s got older their weight become heavier. In the case of circumference items, the significance was acknowledged in all the items except items of chest circumference, hip circumference and stature. On the other hand, as Korean women in 20s~30 got older their stature decreased, but their weight got heavier. In the case of circumference items, the significant was acknowledged in all the items except items of thigh circumference, calf circumference and minimum leg circumference. In addition, the value of anthropometry of Chinese and Korean women had some difference. Especially item chest circumference and hip circumference were higher in Korean women, and these body sizes were related with the obesity. Also, it was revealed that Korean women were exposed to obesity more than Chinese women. In the case of both Chinese and Korean women, the index of obesity belonged to the range of normality, but the body fat rate and BMI Index of Korean women were a little higher than in Chinese women.