• 제목/요약/키워드: half-power method

검색결과 356건 처리시간 0.026초

AC PDP의 무효전력 감소를 위한 CLHS 구동 방법 (CLHS Driving Method for Reducing Reactive Power Consumption in AC PDP)

  • 신재화;김근수
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.577-583
    • /
    • 2011
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration and long gap. However, it is very difficult to apply above technologies because they make many problems such as mis-discharge and high driving voltage. Especially, the reactive power of PDP must be reduced for satisfaction in international standard IEC62087. In this paper, we proposed CLHS driving method which is half sustain driver without energy recovery capacitor. In the experimental results, CLHS driving method reduced reactive power consumption about 10%. Also, CLHS driving method improved the luminance efficiency in all discharge loads. Therefor, the more the discharge load decreases, the more the luminance efficiency improves. When the discharge load is 20%, CLHS driving method improved 5.35%.

A Hybrid Modular Multilevel Converter Topology with an Improved Nearest Level Modulation Method

  • Wang, Jun;Han, Xu;Ma, Hao;Bai, Zhihong
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.96-105
    • /
    • 2017
  • In this paper, a hybrid modular multilevel converter (MMC) topology with an improved nearest level modulation method is proposed for medium-voltage high-power applications. The arm of the proposed topology contains N series connected half-bridge submodules (HBSMs), one full-bridge submodule (FBSM) and an inductor. By exploiting the FBSM, half-level voltages are obtained in the arm voltages. Therefore, an output voltage with a 2N+1 level number can be generated. Moreover, the total level number of the inserted submodules (SMs) is a constant. Thus, there is no pulse voltage across the arm inductors, and the SM capacitor voltage is rated. With the proposed voltage balancing method, the capacitor voltage of the HBSM is twice the voltage of the FBSM, and each IGBT of the FBSM has a relatively low switching frequency and an equalized conduction loss. The capacitor voltage balancing methods of the two kinds of SMs are implemented independently. As a result, the switching frequency of the HBSM is not increased compared to the conventional MMC. In addition, according to a theoretical calculation of the total harmonic distortion of the electromotive force (EMF), the voltage quality with the presented method can be significantly enhanced when the SM number is relatively small. Simulation and experimental results obtained with a MMC-based inverter verify the validity of the developed method.

Design of Bootstrap Power Supply for Half-Bridge Circuits using Snubber Energy Regeneration

  • Chung, Se-Kyo;Lim, Jung-Gyu
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.294-300
    • /
    • 2007
  • This paper deals with a design of a bootstrap power supply using snubber energy regeneration, which is used to power a high-side gate driver of a half-bridge circuit. In the proposed circuit, the energy stored in the low-side snubber capacitor is transferred to the high-side bootstrap capacitor without any magnetic components. Thus, the power dissipation in the RCD snubber can be effectively reduced. The operation principle and design method of the proposed circuit are presented. The experimental results are also provided to show the validity of the proposed circuit.

A Capacitor-Charging Power Supply Using a Series-Resonant Three-Level Inverter Topology

  • Song I. H.;Shin H. S.;Choi C. H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.301-303
    • /
    • 2001
  • In this paper we present a Capacitor Charging Power Supply (CCPS) using a series-resonant three-level inverter topology to improve voltage regulation and use semiconductor switches having low blocking voltage capability such as MOSFETs. This inverter can be operated with two modes, Full Power Mode (FPM) and Half Power Mode (HPM). In FPM inverter supplies the high frequency step up transformer with full DC-link voltage and in HPM with half DC-link voltage. HPM switching method will be adopted when CCPS output voltage reaches the preset target value and operates in refresh mode-charge is maintained on the capacitor. In this topology each semiconductor devices blocks a half of the DC-link voltage[2]. A 15kW, 30kV CCPS has been built and will be tested for an electric precipitator application. The CCPS operates from an input voltage of 500VDC and has a variable output voltage between 10 to 30kV and 1kHz repetition rate at 44nF capacitive load [3]. A resonant frequency of 67.9kHz was selected and a voltage regulation of $0.83\%$ has been achieved through the use of half power mode without using the forced cut off the switch current [1]. The theory of operation, circuit topology and test results are given.

  • PDF

Application of Fuzzy Integral Control for Output Regulation of Asymmetric Half-Bridge DC/DC Converter with Current Doubler Rectifier

  • Chung, Gyo-Bum;Kwack, Sun-Geun
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.238-245
    • /
    • 2007
  • This paper considers the problem of regulating the output voltage of a current doubler rectified asymmetric half-bridge (CDRAHB) DC/DC converter via fuzzy integral control. First, we model the dynamic characteristics of the CDRAHB converter with the state-space averaging method, and after introducing an additional integral state of the output regulation error, we obtain the Takagi-Sugeno (TS) fuzzy model for the augmented system. Second, the concept of parallel distributed compensation is applied to the design of the TS fuzzy integral controller, in which the state feedback gains are obtained by solving the linear matrix inequalities (LMIs). Finally, numerical simulations of the considered design method are compared to those of the conventional method, in which a compensated error amplifier is designed for the stability of the feedback control loop.

A New Half-bridge Resonant Inverter with Load-Freewheeling Modes

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.249-256
    • /
    • 2007
  • This paper presents a new circuit topology and its digital control scheme for a half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in load-freewheeling modes, the pulse-width modulation (PWM) method can be used for the output power control. The proposed half-bridge inverter is based on the resonant frequency-tracking algorithm with the goal of maintaining the unity of the output displacement factor of the load impedance even in varying conditions. In this paper, the operation principle, electrical characteristics, and detailed digital control scheme of the proposed half-bridge resonant inverter are described. The experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge inverter are presented and discussed.

An Improved Asymmetric Half-Bridge Converter for Switched Reluctance Motor in Low-Speed Operation with Current Regulated Mode

  • Woothipatanapan, Sakhon;Chancharoensook, Phop;Jangwanitlert, Anuwat
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1533-1546
    • /
    • 2015
  • This study presents a novel method for reducing the switching losses of an asymmetric half-bridge converter for a three-phase, 12/8 switched reluctance motor operated in low speed. In particular, this study aims to reduce the switching-off losses of chopping switches in the converter when operated in the current regulated mode (chopping mode). The proposed method uses the mixed parallel operation of IGBT (chopping switch) and MOSFET (auxiliary switch). MOSFET is precisely controlled to momentarily conduct prior to the turn-off interval of the IGBT. Consequently, the voltage across the switches is clamped to approximately zero, substantially decreasing the turn-off switching losses. The analytical expressions of power losses are extensively elaborated. Compared with the conventional asymmetric half-bridge converter, the modified converter can effectively minimize the switching losses. Therefore, the efficiency of the converter is eventually improved. Computer simulation and experimental results confirm the effectiveness of the proposed technique.

Power module stray inductance extraction: Theoretical and experimental analysis

  • Jung, Dong Yun;Jang, Hyun Gyu;Cho, Doohyung;Kwon, Sungkyu;Won, Jong Il;Lee, Seong Hyun;Park, Kun Sik;Lim, Jong-Won;Bae, Joung Hwan;Choi, Yun Hwa
    • ETRI Journal
    • /
    • 제43권5호
    • /
    • pp.891-899
    • /
    • 2021
  • We propose a stray inductance extraction method on power modules of the few-kilovolts/several-hundred-amperes class using only low voltages and low currents. The method incorporates a double-pulse generator, a level shifter, a switching device, and a load inductor. The conventional approach generally requires a high voltage of more than half the power module's rated voltage and a high current of around half the rated current. In contrast, the proposed method requires a low voltage and low current environment regardless of the power module's rated voltage because the module is measured in a turn-off state. Both theoretical and experimental results are provided. A physical circuit board was fabricated, and the method was applied to three commercial power modules with EconoDUAL3 cases. The obtained stray inductance values differed from the manufacturer-provided values by less than 1.65 nH, thus demonstrating the method's accuracy. The greatest advantage of the proposed approach is that high voltages or high currents are not required.

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

넓은 입력 전압 범위를 갖는 새로운 비대칭 PWM 방식의 양방향 하프브리지 컨버터 (A New Asymmetrical PWM Bidirectional Half Bridge Converter for Wide Input Voltage Range Applications)

  • 김정근;최세완;박래관;장서건
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.235-242
    • /
    • 2009
  • 본 논문에서는 새로운 비대칭 PWM 제어 방식의 양방향 하프브리지 컨버터를 제안한다. 제안한 컨버터는 구조가 간단하고 넓은 듀티 범위를 가지므로 연료전지와 같은 넓은 전압변동을 가지는 응용에 적합하다. 제안한 비대칭 PWM 방식은 기존의 위상각제어 방식에 비해 스위치 및 변압기의 동작전류를 큰 폭으로 낮추었고 ZVZCS와 동기 정류 방식을 적용하여 높은 효율과 전력밀도를 가질 수 있다. 기존 컨버터와의 비교 분석을 수행하였으며 실험을 통해 본 방식의 타당성을 검증하였다.