• Title/Summary/Keyword: guideline value

Search Result 463, Processing Time 0.037 seconds

Dietary Intake and Potential Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Various Marine Organisms in Korea

  • Moon Hyo-Bang;Lee Su-Jeong;Park Jong-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.7 no.3
    • /
    • pp.141-147
    • /
    • 2004
  • Sixteen polycyclic aromatic hydrocarbons (PAHs) were analyzed in seventy marine organisms (40 species) from the Korean coast. PAHs were present in all the organisms. The level of total PAHs in the organisms varied from 0.45 to 224 ng/g dry weight and the carcinogenic PAHs varied from 0.05 to 49.8 ng/g dry weight. The PAHs residues according to the marine organisms showed a highest content in bivalve species, and followed by crustaceans, cephalopods, fish and gastropods. Human dietary intake of total PAHs through marine organism in Korea was estimated to be 4.12 ng/kg body weight/day and 0.67 ng/kg body weight/day for carcinogenic PAHs. The relative contributions of individual species to the total dietary intake of PAHs were in the order of bivalves $(53.4{\%})$, fish $(21.9{\%})$, crustaceans $(15.3{\%})$, cephalopods $(8.8{\%})$ and gastropods $(0.6{\%})$. Daily dietary intake of $PAH_{TEQ}$ expressed as a TEQ value was estimated to be 0.13 pg TEQ/kg body weight/day, which did not exceed a tolerable daily intake (TDI) proposed by the KFDA and the WHO as well as the UK toxicity committee. Lifetime cancer risk due to ingestion of marine species by the Korean adult was evaluated using the equation estimating exposure of food ingestion. Although approximately $23{\%}$ of cumulative frequency of the sampled marine species exceeded the cancer risk guideline, lifetime cancer risk associated with marine organism consumption was negligible. Results indicate that dietary intake of PAHs through the consumption of the Korean marine organisms seems to be safe for human ingestion with negligible cancer risk.

Appraisal methods based on business analysis far selecting permanent archives : Focused on National Assembly (장기보존기록물 선별을 위한 업무분석적 평가방안 국회를 중심으로)

  • Lee, Won-Young;Lim, Hyo-Jung
    • Journal of the Korean Society for information Management
    • /
    • v.23 no.3 s.61
    • /
    • pp.187-204
    • /
    • 2006
  • The main purpose of the archives is to maintain a history of the organization's functions and activities. Selecting valuable records for the permanent archives through objective appraisal from among many records that reflects the activities of organization is very important but also very difficult. The quantity and complexity of comtemporary records has rapidly expanded because of electronic storage, and with the information environment, and it is now possible to manage and control the records an entire lifetime. In this study, it is proposed the appraisal methods based on a business analysis that is combined the macro-appraisal factor and micro-appraisal factor; The former is functions and organizations as the objective guideline of selecting valuable records from the beginning and the latter is a contents appraisal (evidential value) of the individual records.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Position of Stop Line according to the Left Turn Trajectory at Intersection (교차로 좌회전 궤적에 따른 정지선 위치에 관한 연구)

  • 김기용;김동녕
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.3
    • /
    • pp.29-39
    • /
    • 2000
  • Position of stop line according to left turn trajectory at intersections was studied. The Purpose of this study is to suggest a design guideline of left turn trajectory at intersections which is related to the Position of cross road stop line. Distance from the curb line to the stop line at each lane was calculated and discussed for various combination of road widths. Three design vehicle type and three control radii were considered. Setbacks of stop line from the curb line are Proportional to the control radius which depends on type of design vehicle. 8m, lim and 19m setback for control radius of 12m, 15m and 23m were calculated respectively as their maximum value. This result will be helpful to Paint the road marking on the Pavement which is usually difficult to fit to the designated radius. Field study of the effect of left turn trajectory on flow rate and safety was conducted. It was approved that improperly designed left turn trajectory decreases left turn capacity and increases conflicts among left turn flows of the adjacent lane.

  • PDF

Clinical Benefits of Self-monitoring of Blood Glucose in Non-insulin Treated Patients with Type 2 Diabetes : A systematic Review and Meta-analysis (제 2형 당뇨 환자에서 자가혈당측정의 임상적 유용성 : 체계적문헌고찰 및 메타분석)

  • Choi, Yoon-Young;Sohn, Hyun-Soon;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.183-192
    • /
    • 2010
  • While Self-monitoring of blood glucose (SMBG) has been recommended in some diabetes mellitus (DM) patients population according to the 2010 American Diabetes Association (ADA), 2007 Korean Diabetes Association (KDA), 2005 International Diabetes Federation guideline, it is excluded from a routine insurance coverage for outpatients in Korea. The objective of this study is to meta-analyze the impact of SMBG on HbA1c in non insulin-treated diabetes mellitus (NIT) DM patients. Published clinical literatures were identified through electronic database searches from inception and until May 2010. Studies were selected if they met the following inclusion criteria: 1) randomized controlled trials (RCTs), 2) comparing SMBG with non-SMBG in NIT type 2 diabetes, 3) measuring HbA1c as an outcome. Literature qualities were assessed by the Scottish Intercollegiate Guidelines Network Checklist. The mean difference of HbA1c between the 2 groups was pooled from non-heterogeneous 6 RCTs by meta-analysis using Review Manger (RevMan) Version 5.0 program. Pooled results demonstrated that SMBG is associated with a statistically significant improvement in glycemic control (mean HbA1c difference -0.23, 95%CI -0.32, -0.13). Sensitivity analysis showed that glycemic controls were significantly improved in patients with shorter study duration, more frequent self-monitoring, higher baseline HbA1c value, and without prior SMBG experiences. Conclusively SMBG is effective in improving glycemic control in NIT DM patients, but additional evidences from further researches in Korean patients and cost-effectiveness analysis would be necessary to make a suggestion for coverage expansion.

Assessment of the Best Available Technology to Establish the Industrial Wastewater Effluent Limitations Guidelines (처리기술 수준에 근거한 배출허용기준 설정을 위한 BAT 도입 연구)

  • Lim, Byung-Jin;Kwon, O-Sang;Kim, Young-Noh
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.281-288
    • /
    • 2005
  • BAT (Best Available Technology economically achievable) assessment is indispensible to effective management policy of industrial wastewater discharging facilities such as setting effluent limitations guidelines for individual industry based on the wastewater characteristics and treatment efficiency, making effluent limitations guidelines for new sources, and calculation of the reducible amount of emission load conforming to a total emission general plan and enforcement plan. This study reviewed foreign cases of BAT assessment and condition of domestic wastewater discharging facilities, and suggested BAT assessment guideline suitable for the domestic conditions. The major assessment factors and flow are; (1) Identification of pollution source characteristics, (2) Identification and survey on technology, (3) Selection of candidate technology, (4) Assessment of legislation adaptation, (5) Assessment of environmental factor, (6) Assessment of economical acceptability, (7) Total weighting value factor assessment on technological factor, and (8) Total assessment and final BAT selection. The result of this study can be utilized as a major policy data and a base of industrial wastewater management system.

A Study on Designing of a Menu Structure for the Instrument Cluster IVIS using Taguchi Method (다구찌 방법을 이용한 Instrument Cluster 상의 IVIS 메뉴 설계에 대한 연구)

  • Hong, Seung-P.;Kim, Seong-M.;Park, Sung-Joon;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • The growth of function in vehicle needs complex display and control system, the In-Vehicle Information System(IVIS). Although current IVISs are widely implemented in commercial vehicles, a new form of IVIS has been recently studied in order to reduce drivers' workloads. The purpose of this study is to suggest an appropriate menu structure of a new type IVIS, to be implemented on the instrument cluster panel, using Taguchi's parameter design. In the research, firstly, functions were selected that are appropriate to control through the instrument cluster among existing functions of current IVISs by quantitative evaluation of ergonomic principles. Then, menu structure alternatives were extracted by investigating priorities to those functions selected. Finally, menu structure alternatives were evaluated through an experiment and suggest the most appropriate one by applying Taguchi's parameter design. Taguchi method was used not only for planning an experiment but also evaluating alternatives. SN ratios were a key value to evaluate the alternatives and to find the most proper one. Through the research, the most appropriate menu structure for the instrument cluster IVIS was finally suggested among the alternatives and it is expected that the results of this research could provide a guideline to the instrument cluster IVIS.

A Study on Auditory Perception Characteristics of Directional Tonal Noise (방향성을 가진 회전체 소음의 청각계 인지 특성에 관한 연구)

  • Seo, Kang-Won;Kim, Eui-Youl;Kim, Sung-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.348-353
    • /
    • 2012
  • This paper presents the HRTF based experimental approach to figure out why the human auditory perception on the interior noise source including the directional tonal components does not well match with the dominant features extracted from recorded acoustic signals in terms of psycho-acoustics. Since the general objective evaluation models for tonalness among various sound attributes are a function of width, frequency, excessive level of tonal components respectively, the directional tonal components cannot be properly evaluated without considering the effects of head-related transfer function on the binaural auditory perception. Thus, the directivity of source is additionally considered to prevent the erroneous conclusions from the same sound source in the process of source identification. The signal synthesis technique is used to solve a little difficulty in measuring all of desired acoustic signals for jury evaluation. The sound attributes of synthetic acoustics signals are analyzed to roughly predict the results of jury evaluation in advance by using sound quality factors such as loudness, sharpness, roughness, fluctuation strength and tonality. The jury evaluation is carefully conducted based on the recommended guideline suggested by N. Ottoet al. Each sound is respectively evaluated by selecting a value between -2 and 2 in intervals of 0.2 point. Through above procedure, based on the results of jury evaluation, it is confirmed that serious problems can be caused in the process of analyzing the dominant sound attributes in terms of psycho-acoustics according to the type of a microphone and a playback system.

  • PDF

Comparison of LDL-Cholesterol direct measurement with the estimate using various formula

  • Kwon, Se Young;Na, Young-Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.103-111
    • /
    • 2012
  • Low-Density Lipoprotein cholesterol (LDLC) is the most important marker for the treatment of hyperlipidemia in NCEP-ATP III(National Cholesterol Education Program-Adult Treatment Panel III) guideline. Therefore, LDL cholesterol is pathologically meaningful, accurate measurement should be a top priority. Currently, LDLC is directly measured in most cases, but, the estimate is still used in mass health examination or screening test. This study is about the comparison of LDL-Cholesterol direct measurement with the estimate using various formula (Friedewald: [LDL-F=TC-HDL-TG/5], Nakajima: [LDL-N=TC-HDL-TG/4], Hattori: [LDL-H =0.94TC-0.94HDL-0.19TG], Puavilai: [LDL-P=TC-HDL-TG/6], Carvalho: [LDL-C=3(TC-HDL)/4]) for calculating more accurate value. We analyzed total cholesterol (TC), try-glyceride (TG), high-density lipoprotein cholesterol (HDLC), and LDLC levels of 210 subjects between June and November in 2011. Until now, the Friedewald formula is the most commonly used estimate for the LDLC. When Friedewald formula was applied, the correlation coefficient (r) was 0.940, showing high correlation. But, the result of the direct method was significantly different, compared with those of the Friedewald formula in triglyceride levels ${\geq}400mg/dL$(p<0.05). There was the highest correlation when we used LDL-P formula(r=0.947) in triglyceride levels <400 mg/dl. Also there was the lowest mean difference regardless of triglyceride level. Therefore, the study showed that TG/6 is more precise means of calculation than TG/5. On the other hand, the calculation of LDL-Cholesterol was underestimated, compared with direct measurement. It is necessary to have more data and modified Friedewald formula should be used for the accurate calculation.

  • PDF

Determination of Shelf Life for Butter and Cheese Products in Actual and Accelerated Conditions

  • Park, Jung-Min;Shin, Jin-Ho;Bak, Da-Jeong;Kim, Na-Kyeong;Lim, Kwang-Sei;Yang, Cheul-Young;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.34 no.2
    • /
    • pp.245-251
    • /
    • 2014
  • The aim of this study was to estimate the shelf life of butter and cheese products, with shelf life being a guide used to determine the storage period of food before deterioration. Butter and cheese samples stored at $10^{\circ}C$ and $15^{\circ}C$ had a shelf life of 221 d, while those stored at $25^{\circ}C$ and $35^{\circ}C$ had a shelf life of 109 d. Quality changes, including total cell count, coliform counts, Listeria monocytogenes counts, acid value, moisture content, pH, acidity and overall sensory evaluation, were monitored. In order to pass the overall sensory evaluation, a quality score of 5 points on a 9-point scale was required. For other quality criteria, legal quality limits were established based on the "Process Criteria and Ingredient Standard of Livestock Products" by the Animal, Plant and Fisheries Quarantine and Inspection Agency (Republic of Korea). The nonlegal quality limit was estimated by regression analysis between non-quality criteria (y) and overall sensory evaluation (x). The shelf life was estimated based on the number of days that the product passed the quality limit of the quality criteria. The shelf life of samples stored at $10^{\circ}C$, $15^{\circ}C$, $25^{\circ}C$ and $35^{\circ}C$ was 21.94, 17.18, 6.10 and 0.58 mon, respectively, for butter and 10.81, 9.47, 4.64 and 0.20 mon, respectively, for cheese.