• Title/Summary/Keyword: guide wire

Search Result 84, Processing Time 0.025 seconds

Development of Teflon Coating Equipment Used in Medical Treatment (의료용 가이드 와이어의 테프론 코팅 장치 개발)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.344-349
    • /
    • 2018
  • This paper proposes a method of designing the main parameters of the Teflon coating equipment of a guide wire used in medical treatment. The proposed device was designed to be guided by a reel-to-reel method in which the guide wire performs all processes continuously, such as Teflon coating and heat treatment. At this time, the conveyed guide wire vibrates between the rollers, which affects the quality of the coating. Therefore, this paper proposes a dynamic equation of the guide wire to be transported in the longitudinal direction, and design parameters setting method of the feed speed and the interval of the roller supporting the wire is proposed to minimize the vibration amplitude of the guide wire during transport. The Teflon coating of the medical guide wire was carried out based on the developed coating equipment. The target coating thickness of the guide wire was set to less than $10{\mu}m$ in the circumferential direction, and the results were examined by optical microscopy.

Guide wire fracture during percutaneous coronary intervention (경피적 관상동맥 확장 성형술 도중 우관상동맥 뒤가쪽가지에서 발생한 유도철사 부러짐)

  • Kim, Hak Ro;Yim, Tae Hoon;Kim, Byung Chul;Lee, Ho Jun;Oh, Hong Geun;Ju, Hyun Sik;Kim, Tae Jin;Kim, Young Bok
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.1
    • /
    • pp.52-55
    • /
    • 2016
  • Guide wire fracture during percutaneous coronary intervention (PCI) is rare. It can cause fatal complications such as thrombus formation, embolization, and perforation. Guide wire fracture could occur during intervention for severely calcified stenotic lesions, and rarely from distal small branches of stenotic lesions. There are several methods for its management depending on the material character, position, length of the remnant, and the patient's condition. If percutaneous retrieval was not achieved, the surgical procedure should be considered for prevention of potential risks, although the remnant guide wire does not usually cause complications. We experienced a patient with a guide wire fracture during PCI, and managed to prevent its complications through surgical removal of the remnant wire. We report this case here.

The Development of Monitoring System for Guide Roller in Wire Rolling Process (선재 가이드롤러 모니터링 시스템 개발)

  • Son, Bong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.671-673
    • /
    • 1999
  • In order to cope with the occurrence of abnormal operation, rotatory condition monitoring system for guide roller of finishing train in wire rolling has been developed. In this study, proximity sensor and its holding devices that could overcome severe in-situ measurement conditions was designed and MMI software using C++ was programmed. Performance of the developed system turned out to be good enough as results of in-line test for POSCO #3 wire rolling mill. It is expected to contribute to prevent the cobble and the grade-down of products caused by the abnornormal operation of guide rollers.

  • PDF

Safe Placement of Urethral Foley Catheter Using Guide Wire in Patient with False Passage (Urethral False Tract가 있는 환자에 있어서 Guide Wire를 이용한 안전한 Foley Catheter의 유치방법)

  • Kim, Young-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.101-104
    • /
    • 1988
  • A simple and safe method of urethral Foley catheterization using guide wire was devised and applicated to 7 patients with urethral false tract and 3 patients underwent transurethral resection of the prostate for benign prostatic hypertrophy with success in all without difficulties.

  • PDF

A Human Error-Free Wiring Guide System (휴먼 에러 방지용 배선 안내 시스템 개발)

  • Lee, Hyun Chan;Kim, Joo Han;Kim, Jinsung;Jeong, YeonUk
    • Korean Journal of Computational Design and Engineering
    • /
    • v.22 no.2
    • /
    • pp.181-189
    • /
    • 2017
  • In this paper, we develop a human error-free wire connection guide system. The only related work is Japanese patent by Hitachi. The patent is guiding the wire connection using PC server. And no implementation details have been reported publicly. We propose a new method based on smart mobile devices. The proposed methods are registered as two Korean patents. We implement a prototype wire connection guide system to verify the patents. Through human experiments, we verify the system can reduce the human error more than 90% and speed up the connection process more than twice faster than working without the system. To be used in the industrial fields, the prototype system needs more product packaging works.

A New Technique for Fabrication of Bonded Linqual Retainer (Bonded Linqual Retainer의 최신 제작기술)

  • Yu, Chin-Ho
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.91-98
    • /
    • 1998
  • Bonded lingual retained are divided into two common types; preformed retainers with attached mash pads, and those that are custom fabricated from standard round ir multi-standed wire. The clinician may encounter problems in the bonding process of both types of retainers because of an inability to accurtely place and temporarily stability the wire in the same position as it was adapted an a guide model. Because of these problems, a new fabrication technique of bonded lingual retainers which increase their accuracy and ease of placement and also increased their tretention was suggested by the author. Using a current model as a guide, this bonded lingual retainer was fabricated from $.028"{\sim}.032"$ standard round wire. The wire was formed with pliers for idel adapation to the lingual surfaces of the involved teeth. Right angle bends were placed in the retainer wire ends and custom "composite" bonding pads were added to the ends of the retainer wire. This bonded lingual retainer with custom "composite" bonding pads is easir to place because of the increased stability and the accuracy of placement is greatly increased. The increased insure that the retainer comforms ideally to the lingual surface of the teeth being retained.

  • PDF

Percutaneous femoral access: Stuck guide wire, decannulation difficulty due to unravelling and knotting

  • Bhanu Pratap Singh Chauhan;Binita Dholakia;Ashfaque Khan;Chirag Hirani;Satheesh Kumar;Dibya Jyoti Mahakul;Abhishek Katyal;Wajid Nazir;Daljit Singh
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.223-226
    • /
    • 2024
  • Percutaneous techniques for femoral arterial access are increasingly being performed due to advances in endovascular cerebral procedures, as they provide a less morbid and minimally invasive approach than open procedures. Common complications associated with this peripheral puncture include hematoma, bleeding, pseudoaneurysm, arteriovenous fistula, retroperitoneal bleeding, inadvertent venous puncture, dissection, etc. The retrograde femoral access is currently the most frequently used arterial access as it is technically straightforward, allows for the use of larger size sheaths and catheters, allows repeated attempts, etc. Although being technically less challenging, grave complications can occur due to hardware failure. Here, we present a case of unruptured posterior inferior cerebellar artery (PICA) aneurysm, who underwent uneventful diagnostic cerebral digital substraction angiography (DSA) via right femoral artery route on first attempt, but on second attempt for therapeutic intervention, landed up with stuck guide wire and faced decannulation difficulty due to unravelling of guide wire and multiple knot formation, which was finally removed after multiple attempts at pulling and improvised manoeuvres. Such cannulation and decannulation difficulties have been reported multiple times for central venous access, but extremely rarely for femoral routes, making this case a rarity and worth reporting.

A Study on Stability Hanging Guide Frame used in Floating Crane (해상 Crane용 Guide Frame의 안정성에 관한 연구)

  • 장동일;민인기
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.33-40
    • /
    • 1999
  • In this paper, a damaged example of hanging guide frame used in the lifting of shore protection caisson was investigated. An examination of the stress and stability of members was carried out by structural analysis and the causes of damages was investigated. The stability analysis considering local and global stress buckling was performed. As a result of stability analysis. the first structure was unstable structure. Therefore improved structure was examined and the best effective methodology was the reassignment of wire.

  • PDF

Wear Resistance Evaluation of Contact Tip according to Flux Cored Wire (플럭스 코어드 와이어에 따른 용접 중 콘택트 팁 내마모성 평가)

  • Kim, Dong-Yoon;Hwang, In-Sung;Kim, Dong-Cheol;Kang, Moon-Jin
    • Journal of Welding and Joining
    • /
    • v.31 no.4
    • /
    • pp.42-46
    • /
    • 2013
  • The contact tip for flux cored arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. A damaged contact tip causes a productivity reduction and a welding quality problem. In this study, the welding experiments for the wear resistance of contact tip regarding flux cored wire types were performed. With two fold type and a seamless type flux cored wires, the wear rates of contact tips were compared. In addition, the wear rate was checked according to the contact tip position.

Development of Transportational Guide System for Joining Small Wire with Gabion (개비온 끝단 소둔선 결합용 이송 가이드 장치 개발 연구)

  • Lee J.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.51-52
    • /
    • 2006
  • Gabion can be used for the purpose of preventing overflow of river and side loss of road. However the manufacturing process of the gabion is manually controlled especially to the joining process at the terminal part of gabion with small diameter wire. In this paper automatic feeding guide system was designed and fabricated to make automation. The fabricated system was tested in the factory level. Pneumatic system was considered as the main idea of the feeding system. 3/2-way and 5/2-way manual control valve, eight double-acting cylinders were used. Based on the theoretical simulation and actual test the fabricated system was well controlled. The system was applied to the patent.

  • PDF