• Title/Summary/Keyword: group scanning

Search Result 1,259, Processing Time 0.032 seconds

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

QUANTITATIVE ANALYSIS OF MINERAL CHANCE IN THE INITIAL CAR10US LESION USING CONFORMAL LASER SCANNING MICROSCOPY (공초점 레이저 주사 현미경을 이용한 법랑질 초기 우식 재광화의 정량적 분석)

  • 차승우;윤태철;박성호;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Dental Caries which has high prevalence rate, accounts for majority of dental diseases. Many treatment and preventive treatment has been developed, thereby reducing the prevalence rate, but in our country, fluoridization has not spread widely yet, so prevention has not been done satisfactorily. When dental caries progresses, irreversible damage of tooth structure occurs. In initial dental caries, demineralizing tooth structure can be remineralized, so restorative treatment is unnecessary. In this study, 20 teeth restored with composite resin without fluoride release were used and divided into two groups. Incipient dental caries were artificially made and demineralization procedure was done for 1 and 2 weeks, for each group. Changes in mineral contents around the margins were analysed with confocal laser scanning microscope. The results were as follow. 1. Both total fluorescence of the lesion and average fluorescence of the lesion of remineralized samples decreased compared to demineralizing state. (p<0.01) 2. Confocal laser scanning microscopy can be used in quantitative analysis of mineral change. In result, confocal laser scanning microscopy can be used in quantitative analysis of mineral change and it could be used in many different fields of dentistry in the future.

  • PDF

Time-Matching Poisson Multi-Bernoulli Mixture Filter For Multi-Target Tracking In Sensor Scanning Mode

  • Xingchen Lu;Dahai Jing;Defu Jiang;Ming Liu;Yiyue Gao;Chenyong Tian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.6
    • /
    • pp.1635-1656
    • /
    • 2023
  • In Bayesian multi-target tracking, the Poisson multi-Bernoulli mixture (PMBM) filter is a state-of-the-art filter based on the methodology of random finite set which is a conjugate prior composed of Poisson point process (PPP) and multi-Bernoulli mixture (MBM). In order to improve the random finite set-based filter utilized in multi-target tracking of sensor scanning, this paper introduces the Poisson multi-Bernoulli mixture filter into time-matching Bayesian filtering framework and derive a tractable and principled method, namely: the time-matching Poisson multi-Bernoulli mixture (TM-PMBM) filter. We also provide the Gaussian mixture implementation of the TM-PMBM filter for linear-Gaussian dynamic and measurement models. Subsequently, we compare the performance of the TM-PMBM filter with other RFS filters based on time-matching method with different birth models under directional continuous scanning and out-of-order discontinuous scanning. The results of simulation demonstrate that the proposed filter not only can effectively reduce the influence of sampling time diversity, but also improve the estimated accuracy of target state along with cardinality.

A STUDY ON THE BOND STRENGTH BETWEEN REUSED DENTAL ALLOYS AND PORCELAIN (치과 도재용 금속의 재사용에 따른 금속과 도재간의 결합 강도에 관한 연구)

  • Kim, In;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.181-190
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of shear bond strength between various percentage of reused dental ceramic alloys and porcelain. One hundred specimens were made of one semiprecious alloy and three nonprecious alloys. Each alloy group was subdevided into five groups according to the additional precentage of new alloy. Group I specimens were made of 100% new alloy and served as the control of the investigation. Group II specimens were made of once-cast alloy with 75% new alloy. Group III specimens were made of once-cast alloy with 50% new alloy. Group IV specimens were made of once-cast alloy with 25% new alloy. Group V specimens were made of 100% recast alloy. Five specimens were made for each group of the alloy combinations. The test specimens were prepared by firing porcelain doughnuts on the alloy rod surface, and invested in dental stone. Bond strengths were measured by Instron universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface of metal specimens were examined under the scanning electron microscope. The obtained results were as follows : 1. The shear bond strength of Albabond showed no significant difference between control group and reused alloy group. 2. The shear bond strength of reused alloy groups of nonprecious alloys were lower than that of control groups. 3. The shear bond strength between porcelain and metal in semiprecious alloy was higher than in nonprecious alloys 4. In nonprecious alloys. Rexillium III showed the highest bond strength value and Excelalloy showed the lowest shear bond strength value. 5. Regardless of the type of alloys and additional proportion of new alloys, scanning electron microscope photographs of the fracture surface between alloy and porcelain revealed simillar semiprecious alloy and nonprecious alloys.

  • PDF

THE EFFECT OF TOPICAL FLUORIDES ON SURFACE STRUCTURES OF VARIOUS ESTHETIC RESTORATIVE MATERIALS (불소 제재가 심미 수복 재료의 표면 구조에 미치는 영향)

  • Kim, Un-Yong;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.2
    • /
    • pp.436-448
    • /
    • 1997
  • Topical fluoride application for children is a widely performed procedure in the field of Pediatric Dentistry for its dental caries prevention effects. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surfaces of the restorative materials. In order to evaluate the surface changes in esthetic restorative materials, the author immersed composite resin, glass ionomer cement, and resin-modified glass ionomer cement specimens in various topical fluoride agents and measured the weight loss and also, examined the specimens under the scanning electron microscope. The followings are the results : 1. All the specimens immersed in APF gel for 4 minutes showed statistically significant weight loss. (paired t-test, P<0.05). 2. There was no statistically significant weight loss for the resin-modified glass ionomer cement and composite resin groups immersed in sodium fluoride solution (paired t-test, P>0.05). 3. When the glass ionomer cement group was immersed in APF gel for 1 and 4 minutes, there was a statistically significant weight loss compare to other esthetic restorative materials (ANOVA, P<0.05). 4. In the resin-modified glass ionomer cement group and the composite resin group, weight loss in the APF gel 4 minutes immersion group was greater than the 1 minute immersion group, and it was statistically significant (ANOVA, P<0.05). 5. When the specimens were examined under scanning electron microscope, the surface changes were greatest in the order of glass ionomer cement, resin-modified glass ionomer cement, composite resin and also in the order of APF gel 4 minute immersion group, 1 minute immersion group, sodium fluoride immersion group, and control group.

  • PDF

A Study on the Accuracy of Scan by the Standard Model Deformation Depending on the Hand Scanning Method (핸드스캐닝 작업 방법에 따라 표준 모델 변형이 작업 정밀도에 미치는 정밀스캔에 관한 연구)

  • Shin, Seong-Hun;Jang, Seong-Ho;Song, Joon-Ki;Park, Kwang-Sig;Lee, Hee-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.197-202
    • /
    • 2018
  • This study was conducted to evaluate the distortion and data accuracy that may occur depending on the methods employed by the oral scanner (intra-oral scanner). Deseutap 3D models employing a plaster model used clinically as a scanner to create a standard scan data using the same model, separated by oral scanners in three different ways (AS Group, ZS group, OS group) How to scan each 5 times made the scan data for each group, it shows the 0.121 mm, 0.172 mm AS group, OS group 0.423 mm accuracy in ZS group. The ZS group showed the highest accuracy, with maximum error values of 0.113 mm, 0.169 mm and 0.246 being observed for the ZS, AS and OS group, respectively. The three scanning methods showed a clear differences in accuracy and reproducibility and also appeared to be meaningful in clinical practice.

A Site Specific Characterization Technique and Its Application

  • Kamino, T.;Yaguchi, T.;Ueki, Y.;Ohnish, T.;Umemura, K.;Asayama, K.
    • 한국전자현미경학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.18-22
    • /
    • 2001
  • A technique to characterize specific site of materials using a combination of a dedicated focused ion beam system(FIB), and Intermediate-voltage scanning transmission electron microscope(STEM) or transmission electron microscope(TEM) equipped with a scanning electron microscope(SEM) unit has been developed. The FIB system is used for preparation of electron transparent thin samples, while STEM or TEM is used for localization of a specific site to be milled in the FIB system. An FIB-STEM(TEM) compatible sample holder has been developed to facilitate thin sample preparation with high positional accuracy Positional accuracy of $0.1{\mu}m$ or better can be achieved by the technique. In addition, an FIB micro-sampling technique has been developed to extract a small sample directly from a bulk sample in a FIB system These newly developed techniques were applied for the analysis of specific failure in Si devices and also for characterization of a specific precipitate In a metal sample.

  • PDF

ON THE SURFACE CHARACTERISTICS AND STABILITY OF IMPLANT TREATED WITH ANODIZING OXIDATION (양극산화 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Kim, Won-Sang;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.549-560
    • /
    • 2006
  • Purpose : This experiment examined the effects of anodization on commercially pure titanium implant fixtures. Material & methods : The implant fixtures were anodized at three different voltage levels, producing three different levels of oxidation on the surface of the fixure. Implant were divided into four groups according to the level of oxidation. Group 1 consist of the control group of machined surface implants, Group 2 implants were treated by anodizing to 100 voltage, Group 3 implants were treated by anodizing oxidation to 200 voltage Group 4 implants were treated by anodizing oxidation to 350 voltage. Surface morphology was observed by Scanning Electron Microscope(SEM) and the surface roughness was measured using NanoScan $E-1000^{\circledR}$. Implantation of the fixtures were performed using New Zealand white rabbits. $Periotest^{\circledR}$ value(PTV) resonance frequency analysis(RFA), and removal torque were measured in 0, 2, 4, 8, 12 weeks after implantation. Results : The results of the study were as follows: 1. Values for the measured surface roughness indicate statistically significant differences in Ra, Rq, and Rt values among group 1, 2, 3, and 4 at the top portion of the thread,(p<0.05) while values at the base of the threads indicated no significant difference in these values. 2. A direct correlation between the firming voltage, and surface roughness and irregularities were observed using scanning electron microscope. 3. No statistically significant differences were found between test groups regarding $Periotest^{\circledR}$ values. 4. Analysis of the data produced by RFA, significant differences were found between group 1 and group 4 at 12 weeks after implantation.(p<0.05) Conclusions : In conclusion, no significant differences could be found among test groups up to a certain level of forming voltage threshold, beyond this firming voltage threshold, statistically significant differences occurred as the surface area of the oxide layer increased with the increase in surface porosity, resulting in enhanced bone response and osseointegration.

THE EFFECT OF ND : YAG LASER IRRADIATION ON EXPOSURE OF THE DENTINAL TUBULES ON ROOT SURFACE IN EXTRACTED HUMAN TEETH;A SCANNING ELECTRON MICROSCOPIC STUDY (Nd : YAG laser 조사가 치근면 상아세관의 노출에 미치는 효과에 관한 주사전자현미경적 연구)

  • Cho, Jong-Hee;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.564-576
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of Nd:YAG laser treatment on removal of smear layer and exposure of dentinal tubules. The experimental specimens were obtained from root planed surface of 30 human teeth which were extracted due to severe periodontal disease. The specimens were assigned randomly of three groups: root planed group, Tetracycline HCl(100mg/ml, 5min) group, and Nd:YAG laser ($Laser-35^{TM}$, U.S.A. 5 seconds )group. Nd:YAG laser group was divided into 4 subgroups according to 3.0W, 3.5W, 4.0W, 4.5W of power. The surface change of specimens were evaluated by scanning electron microscopy. The number of exposed dentinal tubules and percentage of area occupied by dentinal tubule orifices per unit area between each group was statistically analyzed by paired Student t-test. The results were as follows: 1. By root planing only, dentinal tubule was not exposed, but scale-like smear layer and parallel instrument tracks were resulted. 2. Tetracycline HCl treated surfaces exhibited the small number of partially exposed dentinal tubules with long orifices. The number($3.80{\pm}0.79$) of exposed dentinal tubules on Tetracycline HCl group was significantly less than that in laser groups above 3.5W of power(P<0.001), and the percentage ($0.68{\pm}0.19$) of area occufied by dentinal tubule orifices per unit area($192\;{\mu}m^2$) was significantly lower than that of any laser group(P<0.001). 3. The laser group irradiated with 4.5W of power showed both the most number($10.60{\pm}0.97$) of exposed dentinal tubules among the experimental groups, and the highest percentage($3.75{\pm}0.55\;%$) of area occupied by dentinal tubule orifices. 4. Energy Surge during laser pulsing and overlapping passes of the fiber resulted in melted and resolidified surface textures with lava-like appearance.

  • PDF

EFFECTS OF PROPLAST I AND II IMPLANTATION ON THE SURROUNDING TISSUE RESPONSE AND BONE FORMATION IN RABBIT MANDIBLE (가토 하악골에 Proplast I과 II 이식후 주위 조직반응 및 골형성)

  • Ryu, Sun-Youl;Kim, Geon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.3
    • /
    • pp.252-264
    • /
    • 1991
  • The purpose of this study was to compare the response of adjacent tissue and new bone formation after implantation by different methods of subperiosteal using using Proplast I and II in rabbit mandible. Microstructure of Proplast I and II was observed by scanning electron microscope. And the implantation procedure was carried out by dividing into tow groups, A and B. a group consisted of subperiosteal graft on the cortex, and the other B group was made up onlay graft following artificial decortication in the madibular body of rabbit. The experimental animals were sacrificed on the 1st, 2nd, 4th and 8th week after grafting for macroscopic and histopathologic examination. The samples extracted at the 6th postgrafting week were also used for biometric test. The result ere as follows : 1. By scanning electron microscopic observation, pore size was $50{\sim}180{\mu}m$ in the Proplast I and $100{\sim}220{\mu}m$ in Proplast II. 2. Macroscopically, infection of the graft site, deformation and displacement of the implanted materials were not observed in all experimental groups. 3. In the tissue response, infiltration of inflammatory cells and multinucleated giant cells were observed from the 2nd to the 8th week in Proplast I. Inflammatory cells decreased in number from the 2nd week in Proplast II suggesting that Proplast II is better than Proplast I. 4. Bone formation was not observed until the 8th week in the group A, but new bone formation from the surrounding graft bed and the periostium was appeared from the 4th week in the group B. 5. The maximum mean values of shear stress mere serially $65.5gf/mm^2$ in Proplast II of group B, $32.9gf/mm^2$ in Proplast I of group B, $17.0gf/mm^2$ in Proplast II of group A, and $15.7gf/mm^2$ in Proplast I. of group A.

  • PDF