• Title/Summary/Keyword: groundwater monitoring

Search Result 561, Processing Time 0.027 seconds

Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province (제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

Monitoring of the Drought in the Upstream Area of Soyang River, Inje-Gun, Kangwon-do Using KOMPSAT-2/3 Satellite (KOMPSAT-2/3 위성을 활용한 강원도 인제군 소양강 상류지역의 가뭄 모니터링)

  • Park, Sung-Jae;Lee, Chang-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1319-1327
    • /
    • 2018
  • Korea has a terrain vulnerable to drought due to the concentration of precipitation in summer and the large amount of groundwater discharge. Quantified drought indices are used to determine these droughts. Among these, drought index is mainly used for analysis of precipitation, and recently, researches have been conducted to monitor drought using satellite images. In this study, we used the KOMPSAT-2/3 image to calculate the water surface area and compare with the drought index in order to monitor the drought in the Upper Soyang River. As a result, it was confirmed that the tendency of the water surface area change and the trend of the drought index were similar in the satellite images. Future research could be used as a basis for judging drought.

Fundamental approach to development of plastic scintillator system for in situ groundwater beta monitoring

  • Lee, UkJae;Choi, Woo Nyun;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1828-1834
    • /
    • 2019
  • The performance of a plastic scintillator for use in an in situ measurement system was analyzed using simulation and experimental methods. The experimental results of four major pure beta-emitting radionuclides, namely $^3H$, $^{14}C$, $^{32}P$, and $^{90}Sr/^{90}Y$, were compared with those obtained using a Monte Carlo N-particle (MCNP) code simulation. The MCNP simulation and experimental results demonstrated good agreement for $^{32}P$ and $^{90}Sr/^{90}Y$, with a relative difference of 1.95% and 0.43% between experimental and simulation efficiencies for $^{32}P$ and $^{90}Sr/^{90}Y$, respectively. However, owing to the short range of beta particles in water, the efficiency for $^{14}C$ was extremely low, and $^3H$ could not be detected. To directly measure the low-energy beta radionuclides considering their short range, a system where the source could flow directly to the scintillator was developed. The optimal thickness of the plastic scintillator was determined based on the suggested diameter. Results showed that the detection efficiency decreases with an increase in the depth of the water. The detection efficiency decreased drastically to approximately 10 cm, and the tendency was gradually constant.

Qualitative Assessment of the Relationship between Site Characteristics and Water Level Fluctuations at the Groundwater Monitoring Wells (지하수 관측망의 현장 특성과 수위 변동의 관계에 대한 정성적 평가)

  • Hwang, Chan-Ik;Park, Hwang-Sung;Kim, Gyoo-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.288-288
    • /
    • 2020
  • 우리나라의 1시간 간격으로 측정되고 있는 지하수 관측망의 지하수위의 변동성은 강우, 양수, 하천, 지표피복에 의한 영향 등 다양하게 나타날 수 있다. 현재 한국수자원공사 및 한국농어촌공사에서 운영중인 지하수 관측망 중에서 지하수위의 변동 양상이 일반적(계절변동, 강우반응 변동 등)이지 않은 것으로 파악되는 101개소(국가지하수관측망 62개, 4대강보 주변 관측망 5개, 해수침투 관측망 15개, 농촌지하수관리관측망 19개)를 대상으로 현장조사를 실시하고 관측정 주변의 특성과 지하수위 변화와의 관계를 정성적으로 분류하여 보았다. 현장 조사는 지하수 관측정 주변 반경 100 m를 대상으로 하였으며, 기존 우물의 존재 및 규모, 지표 피복 상태, 인근 하천과의 관계(표고차, 하천의 규모, 보의 존재 등), 지형적 이상 특성, 저수지 분포 등을 조사하였다. 조사 대상 지하수 관측정 중에서 주변의 인위적인 요인(양수 영향, 하천수위 조절 영향, 지표 피복 변화, 저수지 수위 조절 등)에 의한 변동으로 확인된 것은 총 89개에 해당한다. 이와 같은 지하수위의 이상 데이터는 지하수 모델링, 함양량 산정과 같은 추가적인 분석에 오류를 발생할 수 있으므로 인공신경망 또는 통계 기법을 활용하여 보정하는 과정이 필요해 보인다.

  • PDF

Monitoring Time-Series Subsidence Observation in Incheon Using X-Band COSMO-SkyMed Synthetic Aperture Radar

  • Sang-Hoon Hong
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.2
    • /
    • pp.141-150
    • /
    • 2024
  • Ground subsidence in urban areas is mainly caused by anthropogenic factors such as excessive groundwater extraction and underground infrastructure development in the subsurface composed of soft materials. Global Navigation Satellite System data with high temporal resolution have been widely used to measure surface displacements accurately. However, these point-based terrestrial measurements with the low spatial resolution are somewhat limited in observing two-dimensional continuous surface displacements over large areas. The synthetic aperture radar interferometry (InSAR) technique can construct relatively high spatial resolution surface displacement information with accuracy ranging from millimeters to centimeters. Although constellation operations of SAR satellites have improved the revisit cycle, the temporal resolution of space-based observations is still low compared to in-situ observations. In this study, we evaluate the extraction of a time-series of surface displacement in Incheon Metropolitan City, South Korea, using the small baseline subset technique implemented using the commercial software, Gamma. For this purpose, 24 COSMO-SkyMed X-band SAR observations were collected from July 12, 2011, to August 27, 2012. The time-series surface displacement results were improved by reducing random phase noise, correcting residual phase due to satellite orbit errors, and mitigating nonlinear atmospheric phase artifacts. The perpendicular baseline of the collected COSMO-SkyMed SAR images was set to approximately 2-300 m. The surface displacement related to the ground subsidence was detected approximately 1 cm annually around a few Incheon Subway Line 2 route stations. The sufficient coherence indicates that the satellite orbit has been precisely managed for the interferometric processing.

Monitoring of grout material injected under a reservoir using electrical and electromagnetic surveys (전기비저항 및 전자탐사를 이용한 저수지 하부에 주입된 그라우트 재료의 모니터링)

  • Suzuki, Koichi;Oyama, Takahiro;Kawashima, Fumiharu;Tsukada, Tomoyuki;Jyomori, Akira
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • In order to reduce leakage from a reservoir, a large amount of cement milk (grout) was injected from boreholes drilled around the shores of the reservoir, and monitored to establish the infiltration of cement milk into the bedrock under the reservoir. From laboratory tests using rock core samples, it was revealed that the resistivity of cement milk is much lower than that of the groundwater at this location. Therefore, it was expected that the resistivity of the zones filled with cement milk would be significantly reduced. Geophysical surveys are expected to be suitable methods to check the effectiveness of grouting in improving the water-retaining performance of a reservoir. DC electrical surveys (seven in total) and two Controlled Source Audio-frequency Magneto-Telluric (CSAMT) surveys were conducted along survey lines in the reservoir to monitor the infiltration of cement milk during the grouting. Extremely low resistivity zones ($10\;{\Omega}m$ or less) were observed in resistivity sections obtained by 2D inversion. The zones are inferred to be fractured zones filled with cement milk. In sections showing the rate of change of resistivity, three zones that showed significant change showed gradual expansion to deeper parts as the grouting progressed. These zones correspond to highly permeable zones detected by Lugeon tests at grout boreholes. We have confirmed that it is possible to measure the resistivity change by DC electrical and CSAMT surveys from the surface of the reservoir. It seems that such monitoring results could be reflected in future grouting plans.

Monitoring of Fracture Occurrence During Carbon Dioxide Injection at the Meruap Oil Reservoir, Indonesia (인도네시아 머루압 유전에 이산화탄소 주입 시 균열대 생성 여부 모니터링)

  • Kim, Dowan;Byun, Joongmoo;Kim, Kiseog;Ahn, Taewoong
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • $CO_2$-EOR (Carbon Dioxide-Enhanced Oil Recovery), one of the enhanced oil recovery methods, helps to not only enhance the production of oil, but also store carbon dioxide in underground. However, if micro fractures occur when during the injection of $CO_2$, it is difficult to make permanent storage of $CO_2$ in reservoir and can cause contamination of groundwater and soil. Therefore, in this study, we performed microseismic monitoring to investigate the occurrence of fractures during the $CO_2$ injection at the Meruap oil reservoir, Indonesia. To pick the first arrivals of microseismic events, Improved MER (Modified Energy Ratio) method was used. After picking the first arrivals, hodogram analysis was carried out by using the data recorded at three component geophones to calculate the back azimuth of events. Finally, locations of microseismic events were decided by using the results of first arrival picking and hodogram analysis. Estimated locations showed that all microseismic events were occurred at surface and any fracture did not occur around the reservoir. Moreover, by analyzing noise characteristic, we confirmed that almost of picked first arrivals were due to the repetitive mechanical noise.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF

Characteristics of Groundwater, Sewage Water and Stream Water Contamination Based on VOCs Concentration Around Ulsan, Korea (울산지역 지하수, 하수 및 하천수의 VOCs 오염특성)

  • Cho, Byong-Wook;Yun, Uk;Im, Hyun-Chul;Sung, Ig-Hwan;Jang, Woo-Seog
    • Economic and Environmental Geology
    • /
    • v.38 no.1
    • /
    • pp.57-65
    • /
    • 2005
  • To investigate the characteristics of the volatile organic compounds (VOCs) concentration in the groundwater around Ulsan, Korea, 168 groundwaters, 12 stream waters, and 6 sewage waters were analyzed for 61 VOCs. Results showed that VOCs were not detected in stream waters and total VOCs concentration in 5 sewage waters was in the range of ND-22.3 ${\mu}$g/L. In 78 groundwater samples more than one VOCs were detected and VOCs concentration of the samples ranged from 0.1 ${\mu}$g/L to 387.1 ${\mu}$g/L. However, VOCs concentration of 66 samples out of 78 samples showed less than 10 ${\mu}$g/L and that of only 6 samples exceeded Korea drinking water limit (KDWL). 42 VOCs detected from the 168 groundwaters were 14 aromatic hydrocarbons out of 25, 27 chlorinated aliphatic hydrocarbons out of 35, and methyl tert-butyl ether (MTBE). Detection rate of each VOCs in the groundwaters was as follows: chloroform in 43 samples (25.6%), methylene chloride in 36 samples (21.4%), TCE in 26 samples (15.5%), 1,1-dichloroethane in 19 samples (1.3%), PCE in 16 samples (9.5%), cis-1,2-DCE in 15 samples (8.9%), and toluene in 14 samples (8.3%). Even though VOCs concentration in the groundwaters of the study area is still low, the city is expanding and the drinking water limit is becoming strict, and therefore continuous monitoring is necessary.

Ground Subsidence Caused by the Development of Underground Karstic Networks in Limestone Terrain, Taebag City Korea (석회암 분포지에서 터널시공에 따른 지표침하 원인 분석)

  • Lee, Byung-Joo;Park, SungWook;Kim, Dea-Hong;Song, Young-Karb
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2016
  • The aim of this study is the safety and an accident prevention in limestone terrain by the underground tunneling. The geology of the study area consists of a Paleozoic sedimentary sequence dominated by limestone, sandstone, shale, and carbonaceous shale. The sequence gently dips to the northeast but the joint contains steep with variable trend. A significant fracture zone is developed in the limestone and shale beds, sub-parallel to bedding, and follows in part the limestone-sandstone contact. Monitoring of groundwater levels in the area shows marked fluctuations in the water table, which repeatedly rose to a level of -4 m before sinking to -15 m. These cycles occurred in mid-May, 2007 and in early and middle June. The data indicate that these fluctuations were unrelated to rainfall that occurred during the study period. We infer that the fluctuations were associated with the development of underground karstic networks along the deep fracture zone, and overlying ground subsidence is likely related to the rapid sinking of groundwater and the associated strong downward suction force.