• Title/Summary/Keyword: grounding system

Search Result 467, Processing Time 0.025 seconds

A study of grounding system design with economical efficiency in electric rolling stocks facilities (철도차량기지내에서의 경제성을 고려한 접지설계에 관한 연구)

  • Chang, Chin-Young;Kim, Jae-Moon;Kim, Yang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.6-9
    • /
    • 2009
  • Recently, there have been studied the importance of the grounding system, as electrical equipments installed in the building, such as intelligent building. The object of grounding of electrical facilities is to protect human and machine damage from the power supply interruption high voltage by use of the accident current dissipating into the ground. In this paper, we is proposed to design of grounding system with economical efficiency in electric rolling stocks facilities. To make efficient ground, ground potential rise must be controlled in the way of overall lowering and evenness instead of independent grounding method with respect to electrical facilities.

  • PDF

Spatiotemporal Grounding for a Language Based Cognitive System (언이기반의 인지시스템을 위한 시공간적 기초화)

  • Ahn, Hyun-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.1
    • /
    • pp.111-119
    • /
    • 2009
  • For daily life interaction with human, robots need the capability of encoding and storing cognitive information and retrieving it contextually. In this paper, spatiotemporal grounding of cognitive information for a language based cognitive system is presented. The cognitive information of the event occurred at a robot is described with a sentence, stored in a memory, and retrieved contextually. Each sentence is parsed, discriminated with the functional type of it, and analyzed with argument structure for connecting to cognitive information. With the proposed grounding, the cognitive information is encoded to sentence form and stored in sentence memory with object descriptor. Sentences are retrieved for answering questions of human by searching temporal information from the sentence memory and doing spatial reasoning in schematic imagery. An experiment shows the feasibility and efficiency of the spatiotemporal grounding for advanced service robot.

Charicteristics of Stationary and Transient Ground Impedance of Large-Scale Grounding Piles (임펄스 전류에 대한 대규모 접지시스템의 정상상태 및 과도상태의 접지임피던스 특성)

  • Lee, B.H.;Lee, S.C.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2296-2298
    • /
    • 1999
  • The stationary ground resistance and the transient ground impedance of grounding system are very important parameters in the field of lightning and surge protection. But, it is very difficult to obtain correct values of them in large-scale grounding system. In this paper, the stationary and transient ground impedances of a large-scale grounding system have been measured and analyzed under impulse currents. In order to obtain correct values of them, we have described Z-v(impedance vs ground potential rise) distributions and Z-t waveforms. The transient ground impedance of 36 [m] long three-parallel grounding piles have showed the inductive aspects and the hysterisis region under impulse currents.

  • PDF

Evaluation of Potential Interferences between Grounding Electrodes using an Electrolytic Tank (수조실험장치를 이용한 접지전극 상호간의 전위간섭 평가)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Gil, Hyoung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.29-36
    • /
    • 2006
  • This paper deals with the potential interferences between grounding electrodes in various grounding electrodes. The ground potential rise and potential interference coefficients were measured by using and electrolytic tank and calculated by CDEGS program as functions of the configuration and size of grounding electrodes and the distance between grounding electrodes. The ground potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes, the shape and size of grounding electrodes. The potential rise interferences between grounding grid and grounding grid is lower than those between grounding grid and ground rod.

Impulse Impedance of a Rod type Grounding Electrode (봉형접지전극의 임펄스임피던스 도출)

  • Kim, Wang
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.578-580
    • /
    • 1993
  • The impulse impedence of grounding system must be accurately evaluated for a safe grounding design. However, a calculation nettled of the impulse impendence of a horizontal grounding electrode has not been established yet. This paper presents a method to compute the impulse impedance of a rod type grounding electrode and deals with the analysis of the transient characteristics on the electrodes.

  • PDF

A Study of Ground System improvement on Isolated Power Generation (독립 전원설비에서의 접지방법 개선에 관한 연구)

  • 류보혁;남택주;김정훈
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.96-102
    • /
    • 2001
  • In construction sites, portable generators and electrical equipments cause frequently electrical accidents due to the poor condition of their usage. However, there are very few technical guidelines on these equipments even though they have serious accident causing potentiality. In order to reduce such accidents in practical and economical, grounding methods are studied in this paper as the countermeasure of electrical accidents. Several Korean national standards and international standards regarding three grounding types are compared each other, and some prevention means of electrical accidents are reviewed in this study. This paper presents the most effective grounding methods by assuming the WCS with the isolated power systems.

  • PDF

Construction of Lightning Protection System for Railway Signaling Equipments (철도신호설비용 낙뢰방호장치의 건설)

  • Choi Kyu-Hyoung;Seo Seok-Chul;Choi Se-Wan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1193-1198
    • /
    • 2004
  • This paper describes the lightning protection system for railway signaling equipments installed at subway car depots in Seoul metropolitan Rapid Transit Cooperation. Several measures for improving lightning protection performance are adopted; newly organized grounding system for neutral line of power system, rolling method to minimize damages induced by direct lightning strike, new measures to reduce voltage differences between the signaling equipments and the ground, and improvement of grounding system. The proposed system has greatly reduced the grounding resistance and also the voltage difference between the signaling equipments and the ground, and has prevented the accident related with lightning surges since it was installed. The proposed approach can be viewed as a useful alternative of dealing with lightning protection for railway signaling equipments.

  • PDF

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.

Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System (다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석)

  • Kil, Gyung-Suk;Moon, Byoung-Doo;Kim, Hwang-Kuk;Park, Dae-Won;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

An Improved Model for Grounding System Using process of Grounding Design (접지설비 절차에 따른 개선된 접지실비 모델)

  • Song, Young-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.50-60
    • /
    • 2008
  • The ANSI/IEEE Std. 80-2000 method has been commonly used to design grounding system for the South Korea domestic market. However, the appropriateness of this method to the ground design environment has not yet been examined. This paper presents a new design grounding system method that complements the ANSI/IEEE Std. 80-2000 method, when the new method is a lied to thickness, dangerous voltage, and grid spaced computations for grounding conductors. Furthermore, this paper examines reliability and economic efficiency issues by comparing of the ANSI/IEEE Std. 80-2000 Annex B's case study with the original method.