• 제목/요약/키워드: ground water contamination

검색결과 154건 처리시간 0.022초

호기성퇴비화(好氣性堆肥化)에 의한 농축산(農畜産) 및 기타폐엽물(其他廃葉物)의 녹농지리용(綠農地利用) -현상(現狀)과 장래(將來)- (Composting of Agricultural, Livestock and Other Wastes for Farmland Utilization -Present Situation and Future-)

  • 홍지형
    • Journal of Biosystems Engineering
    • /
    • 제13권3호
    • /
    • pp.81-90
    • /
    • 1988
  • Agricultural and municipal wastes arc serious nuisance. in Korea. Disposal of these wastes by land application, incineration or burial have created serious environmental problems such as air pollution and ground water contamination. Uncomposted waste materials are also potential sources of plant and soil pathogens. As available sites for waste burial become more difficult to find and air quality standards for incineration become stricter, composting as a method for treating solid wastes will become more attractive. This article discussed the recent topics on composting to further develop a rational strategy. The future of composting is developed based on the interacting factors of the price of energy and fertilizer, public policy, economic considerations, and biotechnology.

  • PDF

유류저장시설로 인한 토양오염 예방대책 (Prevention of Soil Contamination from Underground Storage Facilities)

  • 배우근;홍종철;정진욱;강우재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

결합재 및 사용수 변화에 따른 노후저수지 보강용약액주입공법 적용에 관한 연구 (A Study on the Application of Chemical Grouting Method for Aging Reservoir Reinforce According to the Change of Binder and Using Water)

  • 송상훤;서세관
    • 한국농촌건축학회논문집
    • /
    • 제21권4호
    • /
    • pp.45-52
    • /
    • 2019
  • Chemical grouting method is mainly used for construction of dams and reservoirs, stabilization and reinforcement of slopes, reinforcement of soft grounds such as embankments, dredging and landfills, the order of earthquake response method, and the reinforcement of structures. Recently, it is widely applied in construction sites such as highways, airfields, high-speed railways, subsea facilities, port construction works, tunnels, and subway works. As such, the demand for grouting continues to increase. The development of the grouting method was focused on increasing the strength of the ground, and the development of the chemical additives, the injection device, and the stirring device were mainly performed. But ordinary portland cement used for grouting is a product that consumes natural resources such as limestone, generates a large amount of greenhouse gases, consumes a large amount of energy sources, and it is time to develop products and new methods to replace them. In this study, Ordinary Portland Cement and New Grouting Binder (circulating fluidized bed boiler fly and blast furnace slag) were compared and analyzed by the following test. Homo-gel strength and homo-gel time, water quality analysis of the water used and soil contamination process tests of homo-gel samples were performed. In the case of NGB, when Using water is used as the reservoir water, the strength measured smaller than that of the other water. However, it shows about 2.5 times greater than the homo-gel compressive strength applied to OPC (7-day, reservoir water), so there is no problem with water quality when applied.

나림광산 수계에 분포하는 순환수의 수문지구화학 및 오염 (Hydrogeochemistry and Contamination of Meteoric Water at the Narim Mine Creek, Korea)

  • 이찬희
    • 자원환경지질
    • /
    • 제32권4호
    • /
    • pp.385-398
    • /
    • 1999
  • The Narim gold mine is located approimately 200km southeast of Seoul within the Muju mineralized district of the Sobaegsan gneiss complex, Korea. Environmental geochemistry were undertaken for various kinds of water (surface, ground and mine water) collected of April, September and November in 1998 from the narim mine creek. Hydrogeochemical compositions of water samples are characterized by the relatively significant enrichment of Na+K, alkali ions, $HCO_{3}$, $NO_{3}$, Cl and F in groundwater, wheras the mine and surface waters are relatively enriched in Ca+Mg, hea표 metals and $SO_{4}$. Therefore, the groundwaters belong to the (Na+Ca)-( $HCO_{3}+SO_{4}$) type, respectively. The pH and EC values of the non-mining creek surfers are relatively lower compared with those of the surface water of the mine and ore dump area. The d values ($\delta$D-8$\delta^{18}$O) of all kinds of water from the Narim mine creek are 5.8 to 13.1 The range of $\delta$D and $\delta^{18}$O values (relative to SMOW) are shown in distinct two groups as follows: for the April waters of -64.8 to -67.8$\textperthousand$ and -9.6 to -10.0$\textperthousand$(d value=10.1 to 13.1), and for the November waters of -65.9 to -70.2$\textperthousand$ and -9.3 to -9.6$\textperthousand$ (d value=5.8 to 7.9), respectively. This range variation indicates that two group water were composed of distinct waters with seasonal difference. Geochemical modeling showed that mostly toxic metals (As, Fe, Mn, Ni, Pb, Zn) may exist largery in the from of metal $(M2^+)$ and metal-sulfate $(MSO_4\;^{2-$\mid$),\; and \;SO_4^{2-$\mid$}$ concentration influenced the speciation of heavy metals in the meteoric water. These metals in the groundwater could be formed of $CO_3 \;and \;(OH)_3$ complex ions. Using computer program, saturation index of albite, calcite, dolomite in meteoric water show undersaturated and progreddively evolved toward the saturation state, however, ground and mine water are nearly saturated. The gibbsited water-mineral reaction and stabilities suggest that the weathering of silicate minerals may be stable kaolinite, illite and Nasmectite. The clay minerals will be transformed to more stable kaolinite owing to the contiunous reaction.

  • PDF

침출수로 오염된 불포화사질토의 전기비저항 변화에 대한 연구 (A Study on the Variation of Resistivity of the Unsaturated Sandy Soils Contaminated by Leachate)

  • 윤춘경;유찬
    • 한국농공학회지
    • /
    • 제40권2호
    • /
    • pp.112-122
    • /
    • 1998
  • Measurement of electrical resistivity in soils has been used for many years with purpose of estimating in situ porosity or density. Recently electrical resistivity has also been used as an indicator of soil contaimination. This paper presents the result of laboratory experiment to investigate the resistivity variation in contaminated sandy soils. The results can be used with the Cone Penetrometer Test (CPT) result to analyse ground condition. In the experiment, the water content and leachate concentration of soils were controlled by groundwater and leachate, and then the resistivity measurement was made with 'STING-R1' by Advanced Geosciences Inc. In the case of using groundwater, the resistivity was in the range of over 1000${\omega}{\cdot}m$, but in the case of using polluted water by leachate, the resistivity decreased significantly down to 10~ 100${\omega}{\cdot}m$ for the same moisture content. Also the resistivity varied according to the degree of saturatrion. Therefore, if soil is contaminated by leachate, the CPT with electrical resistivity sensor might be used to investigate the contamination status and plume migration. But exact component of leachate and the pollutant concentration are still hard to identify.

  • PDF

골프장 그린 토양에서 Metalaxyl의 흡ㆍ탈착 특성 (Characteristics of Adsorption and Desorption of Metalaxyl in the Green Soil of Golf Course)

  • 유병로;정경희
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.227-234
    • /
    • 2002
  • Laboratory experiments were conducted to examine the behavior of metalaxyl in environment which was used as pesticide in green soil of golf course and as functions of the characteristics of adsorption, desorption and degradation in soil texture and organic matter contents. Acid water containing metalaxyl was conducted to evaluate the effects on adsorption, desorption and degradation. The adsorption of metalaxyl played more significant role in organic contents than clay contents, and pH Increases more pH 2.5 than pH 5.6. The desorption of metalaxyl from contaminants soil decreased higher organic contents LS-soil than S-soil, but the desorption amount of metalaxyl increased more pH 5.6 than pH 2.5. The rate of degradation of metalaxyl in green soil environmental increased higher organic contents LS-soil than S-soil and decreased more pH 2.5 than pH 5.6. These results indicated that the behavior of metalaxyl of the green soil was affected the soil texture of the golf course. Increasing of organic contents, the adsorption amount of metalaxyl on soil increased. Moreover the decrease of the pH of solution increased adsorption amounts and decreased desorption amounts. As the results, the transportation of metalaxyl in soil decreased the acidic rates. The acidification of soil by the acid rain increased the adsorption amount of metalaxyl, but the degradation of metalaxyl decreased. Therefore, it is possible to sustain contamination in run-off the stream and ground water by residuals in soil.

보어홀 처분 개념: 탄자니아의 폐밀봉선원 처분을 위한 제안 (Borehole Disposal Concept: A Proposed Option for Disposal of Spent Sealed Radioactive Sources in Tanzania)

  • 미키다디 살레히;김창락
    • 방사성폐기물학회지
    • /
    • 제11권4호
    • /
    • pp.293-301
    • /
    • 2013
  • 처분공 처분 개념은 아프리카의 방사성폐기물관리 방안의 향상을 위해서 남아프리카에너지주식회사(NECSA)에서 처음으로 제시되었다. 초기에 방사성폐기물의 지층처분방안이 고려되었으나, 지하수를 방사성폐기물 오염으로부터 보호하는 방안과 토양과 지하 암석의 균열지대를 통한 방사성 물질의 이동에 대한 조사가 불가피하게 필요했다. 이러한 이유로 처분공 처분개념이 연구되었다. 처분공 처분 개념은 폐기된 밀봉선원을 상대적으로 좁은 직경(260 mm)의 처분공 시설을 통해 처리 및 처분한다. 탄자니아는 장반감기 및 단반감기의 폐기된 밀봉선원을 방사성폐기물관리시설에 저장하고 있으며 폐기된 밀봉선원의 방사능은 1E-6 Ci 에서 8.8E+3 Ci의 범위로 분포한다. 그러나 영구 처분 문제는 여전히 해결하지 못하고 있다. 본 연구에서는 처분부지 면적이 적고, 이에 따라 인간침입 위험이 줄어드는 처분공 처분개념을 제시하였다.

동위원소를 이용한 한강유역의 지하수와 지표수의 연관성에 관한 연구 (Environment isotope aided studies on river water and ground water interaction in the Han River basin)

  • 안종성;김재성
    • 물과 미래
    • /
    • 제16권4호
    • /
    • pp.245-252
    • /
    • 1983
  • 근년에 이르러 국내 지표수의 오염 현상은 사회적으로 매우 심각한 문제를 야기시키고 있어 수자원의 보호문제가 매우 중요한 시점에 이르렀다. 한강유역내에 발달 분포된 천층의 충적 퇴적층과 결정질암내에 저유된 지하수에 대해 동위원소를 이용한 환경 조사를 시행하였으며 결과를 분석한 바 다음과 같은 가정을 확인하였다. 1) 천층지하수의 함양원은 서울 도심지역은 하천수였고, 교외 외각의 농촌 지역은 강우의 직접 지하 침투에 의해 일어나고 있으며, 2) 충적 퇴적층으로 피복된 결정질 암은 상부충적퇴적층내에 저유된 천층 지하수가 충진원의 역할을 한다. 한강하류부의 해안 가까운 곳에 분포된 일부 충적층과 그 하부의 결정질암내에 저유된 지하수는 $H^3$의 함량이 매우 낮은치를 나타내는데 이는 핵실험이전의 기상수가 상당히 먼곳에서 충진되었기 때문으로 시료된다. 안정동위원소 조사에 의하면 한강상류에 분포된 석회암 대수층의 함양지역은 하류부의 충적층과는 달리 비교적 고지대였으며 석회암 대수층내에서 지하수의 체제 시간은 수개월 정도였다. 지하수의 포함된 극소량의 Pb, Mn, Zn 량과 충진메카니즘을 대비하려고 시도하였으나 명확한 관계가 나타나지 않았다.

  • PDF

장대교량 기초 설계를 위한 수륙혼합 전기비저항탐사 사례 (Case history of electrical resistivity survey at the river for bridge design)

  • 정호준;김정호;권형석;안희윤;김기석
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2002년도 정기총회 및 제4회 특별심포지움
    • /
    • pp.126-138
    • /
    • 2002
  • 근래에 들어 설계되는 교량들은 경간이 넓어지는 추세이며, 이때 교량의 안전성을 위해 적합한 기초 지반을 확보하는 것이 중요한 문제중의 하나이나, 물로 덮힌 강 하부의 정확한 지반정보를 얻는 것은 상당히 어려운 문제이다. 본 논문에서는 교량 건설 부지의 전반적인 지반정보를 획득하기 위해 강 지역에서 실시한 전기비저항 탐사 사례를 소개하고자 한다. 주로 육상에서 실시되었던 전기비저항 탐사는 물로 덮힌 강 지역에서도 강하부의 전기비저항 구조를 성공적으로 파악하였고 시추조사 결과에서 그 정확성이 입증되었다. 강구간에서의 전기비저항탐사 결과는 안전한 교량의 설계를 위한 양호한 교량 기초 위치의 선정에 필요한 단층파쇄대 등의 지질구조에 대한 정보를 제공할 수 있었다. 강물 구간에서의 전기 비저항탐사의 적용은 예상치 못한 지반조건에 의한 시공시의 설계변경 또는 기초지반 보강시 발생하는 수질오염, 건설비용 증가 등을 미연에 방지하는데 도움이 될 것으로 기대된다.

  • PDF

포화된 사질토의 전기전도도에 중금속과 염분 농도가 미치는 영향 (Effects of Heavy Metal and Salinity on Electrical Conductivity in Fully Saturated Sand)

  • 이동수;홍영호;홍원택;채광석;이종섭
    • 한국지반환경공학회 논문집
    • /
    • 제18권10호
    • /
    • pp.23-34
    • /
    • 2017
  • 포화된 흙의 전기적인 특성은 흙 주위에 있는 간극수의 전기전도도에 크게 의존하므로, 흙의 전기전도도 변화를 이용하여 지반속으로의 오염물 침투를 감지하는데 널리 활용되고 있다. 본 연구의 목적은 포화시료에 대해 염분비와 납의 농도 변화에 따른 흙의 전기적 특성 변화를 조사하는 것이다. 전기저항과 시간영역반사법 신호측정을 위한 센서를 매설한 원통형 셀 내부에 담수 및 염분 농도 1%, 2% 그리고 3%의 염수용액을 0~10mg/L 사이의 6가지 납 표준용액과 혼합하여 수용액을 준비하였다. 이후 수용액 속에 건조시킨 모래시료를 수중강사법을 이용하여 조성하였다. 조성된 포화시료에 대해 셀 내부에 설치된 센서들로부터 전기저항과 시간영역반사법 신호를 측정하고 이 결과로부터 전기전도도를 산정하였다. 실험 결과, 주파수 1kHz에서 측정된 전기저항으로 부터 산정한 전기전도도는 납의 농도가 증가함에 따라 연속적으로 증가하는 것으로 나타났으므로 전기저항으로부터 산정한 전기전도도가 오염정도를 파악하기 위해 사용될 수 있는 것으로 나타났다. 또한 시간영역반사법으로부터 산정한 전기전도도의 경우 저농도에서의 납의 농도 변화에도 전기전도도가 변화하지만, 납의 농도가 증가함에 따라 변화 정도는 점차 감소하는 것으로 나타났다. 즉, 시간영역반사법은 중금속 누출여부를 조사하는데 적합한 것으로 평가되었다. 본 연구는 전기저항과 시간영역반사법의 상호보완적인 특성을 활용한다면 해안 및 해양환경에서도 중금속의 누출 및 오염을 감지할 수 있음을 보여준다.