• 제목/요약/키워드: ground uplift

검색결과 68건 처리시간 0.025초

점성토 지반에서의 다중 헬리컬 앵커의 인발 특성 (Pullout Characteristics of Multi Helical Anchors in Clay)

  • 이준대;이봉직;이종규
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.114-121
    • /
    • 1997
  • Helical anchors are foundation structure that designed to resist uplift loads are installed by applying in load to shaft while rotating it into the ground. These can be a cost effective means of proving tension anchorage for foundation where soil conditions permit their installation because of ease of installation. At present time, tapered helical anchors are commonly used to carry uplift loads. The uplift capacity includes the following factors : the height of overburden above the top helix, the resistant along a cylinder, the weight of the soil in the cylinder and suction force. In order to make clear behavior characteristics of helical anchors with pullout, model tests were conducted with respect to various embedment depth, space of helix, shape of helix. Based on the experimental study, the following conclusions are drawn. 1) The uplift capacity of multi helical anchors increase with embedment ratio of anchors The increase is smooth after critical uplift capacity. 2) Critical breakout factors and critical embedment ratio of multi helical anchor exist 7∼8, 4∼6 respectively. 3) Variation of uplift capacity with helix spaces show down after S/D=5. 4) Critical breakout factors of helical anchor in the laboratory test are similar to Das's theory.

  • PDF

셰일지반에 설치된 MC앵커의 인발특성 (Pullout Characteristics of MC Anchor in Shale Layer)

  • 이봉직;김조순;이종규
    • 한국지반환경공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.53-61
    • /
    • 2012
  • 본 연구에서는 복합형 지지방식으로 개발된 MC앵커에 대한 연구를 수행하였다. MC앵커는 선단 정착장치가 확장되어 천공된 공벽에 지압력이 발휘됨에 따라 인발력 증대와 그라우팅이 제대로 이루어지지 않을 경우에도 앵커체가 지반에서 탈락하지 않는 특성이 있다. 또한, 앵커강선과 더불어 보강철근을 삽입하여 인장손실을 감소시키는 동시에 시공성을 높이고 앵커강선의 손실이 발생하였을 때 네일의 역할을 기대할 수 있어 장기적인 안정성 향상을 꾀할 수 있다. 그러나, MC앵커와 같은 복합형 앵커는 마찰형 앵커와 지지구조가 다르기 때문에 지반과 그라우트의 마찰력에 의한 인발력 산정방식은 적합하지 않다. 특히, 국내의 경우에는 복합형 앵커에 대하여 지반특성을 고려한 설계법이 명확하게 정립되어 있지 않아 복합형 앵커의 인발력이 과소 또는 과대 평가되는 문제점이 있다. 따라서, 본 연구에서는 복합형 앵커의 일종인 MC앵커의 특성을 평가하기 위하여 강도변화가 심한 셰일지반을 대상으로 총 9개소에서 시험앵커를 시공하여 인발, 인장 및 장기변위를 측정하였다. 또한, 시험결과를 일반 마찰형 앵커의 경우와 비교, 분석하여 MC앵커의 거동 특성을 평가하였으며, 시험결과 셰일층에서 MC앵커는 일반 마찰형 앵커에 비해 인발력 증대효과를 확인할 수 있었다.

지오컴포지트를 이용한 양압력 제거공법 (Uplift Pressure Removal System in Underground Structure by Utilizing Geocomposite System)

  • 신은철;김종인;박정준
    • 한국지반공학회논문집
    • /
    • 제22권9호
    • /
    • pp.61-68
    • /
    • 2006
  • 최근 대규모 토목 건설 프로젝트는 용지 매입비용 및 각종 민원으로 인하여, 공유수면을 매립하거나 해안 및 하천지역의 용지를 활용하고 있다. 공유수면을 매립한 지반이나 해안 및 하천 지역의 지반은 충분한 지지력을 발휘하지 못하는 연약지반이 대부분이다. 이러한 연약지반은 주로 점토나 실트와 같은 미세한 입자의 흙이나 간극이 큰 유기질토 또는 이탄, 느슨한 모래 등으로 이루어진 토층으로 구성되어 있으며, 지하수위가 높기 때문에, 제체 및 구조물의 안정과 침하 문제를 발생시킬 수 있다. 본 연구에서는 지오컴포지트의 수리특성을 평가하기 위해 상재하중에 따른 통수성과 전수성 실내시험을 수행하였으며, 지하수위가 높은 지반에 지하구조물을 축조할 경우 발생될 수 있는 지하수 누수 및 양압력을 제거하기 위하여 토목섬유를 적용한 배수시스템을 연구하였다. 지반의 조건상 양압력으로 인한 문제점이 많이 발생되는 매립지의 준설토를 이용하여 실내배수실험을 수행하였다. 실내 배수실험에서는 실험기 하부에 토목섬유 배수층을 설치한 후에 상부에 준설토를 다져 넣고 상부에서 단계별 수압을 가하여 배수량과 간극수압을 측정하여 각각의 수압에 따른 계측값들과 이론적인 값들과 비교하였다. 실내배수실험의 타당성을 분석하기 위하여 흙이나 암석과 같은 다공질 재료의 간극수압 분포나 이동을 해석하기 위한 2차원 유한요소 해석프로그램을 이용하여 수치해석을 수행하여 실내실험의 결과와 비교하였다.

풍화암에 근입된 영구 앵커의 극한인발력 (Ultimate Uplift Capacity of Permanent Anchor Embedded in Weathered Rock)

  • 유남재;박병수;정길수;김진황
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.195-203
    • /
    • 2001
  • The purpose of this study is to estimate ultimate uplift capacity of permanent anchor which was cast into weathered rock. The ultimate uplift capacity was estimated from the load-displacement curve of four different anchors which have different bond length. The creep test was performed for 15minutes under the maximum load of each step in order to understand the load-transfer property of permanent anchor and to decide which anchor to choose. The destruction range of soil due to the changes in load was estimated by installing dial gauge on the ground which was cast into the weathered rock. Ultimately, the study on the behavior of the anchor case into the weathered rock was performed by comparing and analyzing the estimated result of the UUC obtained by the full scale pull out test in the field with the exsting theoretical and practical results of soil and rock anchor.

  • PDF

높은 지하수위 지반 속에 설치된 지중연속벽의 인발저항력 (Uplift Capacity of a Diaphragm Wall Installed in Ground with High Groundwater Table)

  • 홍원표;침니타
    • 한국지반공학회논문집
    • /
    • 제30권9호
    • /
    • pp.5-17
    • /
    • 2014
  • 지하수위가 높은 지역에 설치된 지중연속벽 주변지반 속에 발생되는 지중파괴면의 형상을 조사하기 위해 일련의 모형실험을 실시하였다. 모형실험에서 벽체가 인발될 때 발생하는 벽체 주변지반의 변형거동을 사진으로 촬영하여 관찰하였고 이 지반변형 결과를 분석하여 지중연속벽 주변지반에 발생되는 지중파괴면의 형상을 파악할 수 있었다. 이렇게 파악된 지중파괴면의 형상에 근거하여 지중연속벽의 인발저항력을 산정할 수 있는 이론해석을 실시하였다. 이 이론해석에는 벽체와 지반에 관한 주요 특성이 잘 반영되어 있다. 즉 벽체의 특성으로는 벽체의 길이, 두께 및 벽면조도가 포함되어 있으며 지반의 특성에 관하여는 흙의 내부마찰각 및 점착력과 같은 전단강도정수가 포함되어있다. 제안된 해석모델에 의거하여 예측된 지중연속벽의 인발저항력은 모형실험에서 측정된 실험치와 잘 일치하였다.

강체전차선로 이행구간 Heavy Simple Catenary 적용을 위한 압상량 고찰 (A Study on the Uplift for Applying of Heavy Simple Catenary System in a Overhead Rigid Conductor Rail Transition Section)

  • 김완일;박원찬;이재봉;김재문
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.688-694
    • /
    • 2018
  • The transition section of the overhead rigid conductor rail (ORCR) consists of a direct induction device and a limit point to prevent the power supply failure and failure of the electric railway vehicle pantograph due to the difference of the uplift in the catenary line. In T-Bar transition section, a twin simple catenary is mostly installed between the overhead catenary system (OCS) in the ground section and the ORCR in the underground section. In this paper, we compare and analyze the possibility of replacing the twin simple catenary with heavy simple catenary. The reliability of numerical analysis results was confirmed by comparing field test with numerical results. Comparing the numerical results of the twin simple catenary with the heavy simple catenary in the transition section, the difference uplift is 5.9[mm] on average. When applying heavy simple catenary instead of twin simple catenary, the slight difference of uplift can be compensated by adjusting the height of hanger-ear or support bracket.

현장시험을 통한 부력앵커의 거동분석 (An analysis of the Behaviour of Uplift-Resisting Ground Anchors from Pull-out Tests)

  • 이철주;전상현;유남재
    • 한국지반환경공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.33-40
    • /
    • 2007
  • 풍화암층에 시공된 부력앵커의 거동을 현장인발시험을 통하여 분석하였다. 부력앵커는 지하철역사의 지하층에 작용하는 부력을 저항하기 위하여 시공되었다. 본 연구에서는 부력앵커의 한계인발저항력과 앵커와 지반의 경계면에서의 전단응력 전이 메커니즘에 대한 분석을 실시하였다. 인발시험에서는 앵커의 정착장(2~7m)과 천공직경(108~165mm)을 변경시키면서 그 영향을 고찰하였다. 인발시험결과에 의하면 앵커의 한계인발력은 정착장의 길이 및 천공직경이 증가 할수록 증가하는 것으로 분석되었다. 인발시험을 통한 앵커의 한계인발력은 이러한 인자들에 따라 392~1,569kN의 범위를 보이는 것으로 분석되었다. 이로부터 경계면에서 227~505kPa 전단강도가 발생하는 것으로 산정되었다. 인발시험결과에 의하면 인발력의 크기가 증가할수록 전단강도의 발현정도가 증가하는 것으로 나타났다. 인발시험을 통해서 관찰된 파괴 형태는 앵커의 길이에 큰 영향을 받는 것으로 분석되었다. 앵커의 길이가 짧은 경우(2~3m) 콘 형태의 파괴가 관찰되었으며, 앵커의 길이가 증가한 경우(5~7m)는 앵커의 파괴가 앵커체와 주변지반과의 불연속면에서 발생하는 것으로 나타났다.

  • PDF

지하구조물 부력방지를 위한 연직배수시스템의 적용성 연구 (A Study on the Application of Vertical Drainage System for Resisting Uplift of Sub-structure)

  • 천병식;여유현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.183-190
    • /
    • 2001
  • A sub-structure is uplift if the floating greater than dead load of a structure. When such occasion arise, a structure sustain damage. In general, the measures for floating prevention of structure are a permanent anchor method and a drainage method. The primary construction cost of a permanent anchor method is heavy. And a drainage method is needed maintenance management long term. At this point, the measures for floating prevention of a notion being requires the other days. Therefore, at this study a simple construction and a economic vertical drainage system was developed. The findings be used in the in-situ and gave careful consideration to an application. The result of examination, this system considering a characteristic of coefficient of permeability for the ground controls occurrence of floating despite the water level rise of the ground, which a period of construction get shorter compared with other methods, which understood that measures satisfactory in the financial aspect. Especially, A structure occurring effects of flatting under the course of construction made use of it. As the result of the effect of it was confirmed by construction.

  • PDF

대지진에 의한 지하구조물 부상과 지질학적 특성의 상관성 연구 (Study on Correlation between Large Earthquake-Induced Underground Structure Uplift and Geological Settings)

  • 강기천;김지성
    • 한국지반신소재학회논문집
    • /
    • 제15권4호
    • /
    • pp.9-16
    • /
    • 2016
  • 2004년 일본의 니가타켄 츄에츠 지방의 나가오카, 오지야시에서 1,450개 이상의 지하구조물이 1.5m까지 부상하였다. 융기손상은 Lifeline 시스템의 일부인 하수 시스템의 흐름뿐만 아니라 교통흐름을 방해로 인해 심각한 문제를 야기 시킨다. 복구작업의 경우 손상된 하수 시스템의 오픈 컷 조사는 나가오카시 정부에 의해 수행되었다. 지진으로 인한 매설된 파이프 라인의 손상에 대한 중요한 데이터는 조사결과로부터 수집하였다. 본 연구는 지하 구조물의 부상량에 영향을 미치는 요인을 SPT 시추공 logs를 통해 손상된 지역의 위치와 파이프라인의 경사를 포함하는 데이터를 사용하여 조사하였다. 지하구조물의 부상과 영향을 받는 지역의 지질학적 특성 사이의 상관관계 분석을 통해 부상현상의 주요변수는 지하수의 깊이, 원지반에서의 점토층 두께, SPT N값인 것으로 밝혔다.

파이프형 앵커의 인발거동에 대한 연구 (Study on Pullout Behavior of Pipe Anchor)

  • 배우석;이봉직;권영철;이준대
    • 한국지반환경공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.5-10
    • /
    • 2008
  • 본 연구에서는 표면거칠기와 근입비, 직경에 따른 파이프형 앵커의 인발거동을 평가하기 위하여 실내모형실험이 시행되었다. 수직방향의 지반 변형에서 매입된 파이프형 앵커의 설계는 파이프에 부과된 힘의 크기에 의해 지배받는다. 본 논문에서는 모형실험의 분석을 통하여 파이프 직경과 표면 거칠기, 근입비와 지반상태로 야기된 파이프형 앵커의 변위 특성과 극한 저항력을 비교하고 평가하였다. 실험결과는 상대밀도의 증가에 따라 극한 인발력이 20%가량 증가하고 있음을 보여주고 있다. 지반의 상대밀도와 파이프의 지름, 표면거칠기의 변화에 따른 파이프형 앵커의 파괴시 변위는 근입비가 2에서 8로 증가함에 따라 약 5배 정도의 증가 경향을 보였다. 또한 앵커이론에 근거한 이론식들은 인발계수를 과대평가하는 것으로 나타났다.

  • PDF