• Title/Summary/Keyword: ground thermal conductivity

Search Result 160, Processing Time 0.024 seconds

A Case Study on the Effective Thermal Conductivity Measurement in In-situ Thermal Response Test (현장열응답시험을 이용한 지중열전도도 측정 사례연구)

  • Kim, Min-Jun;Choi, Choong-Hyun;Woo, Jeong-Tae;Chang, Keun-Sun;Kang, Hee-Jeong;Seo, Jeong-Sik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.123.2-123.2
    • /
    • 2010
  • 본 논문에서는 2008년 4월 이후 지열원 열펌프가 설치되어지는 현장에 시험공의 지중열전도도를 현장열응답법을 이용하여 측정하였으며, 그간에 측정된 지중열전도도를 이용하여 전국의 지중온도 및 지중열전도도의 산포도를 정리하였다. 지중열교환기의 심도가 150m일 때 지중온도 분포는 약 $12.0{\sim}19^{\circ}C$의 넓은 분포를 보였으나 대부분의 지중온도가 $15.0{\sim}17.0^{\circ}C$의 범위에 분포하였으며, 지중열전도도의 경우도 마찬가지로 1.50 ~ 9.00 W/mk 값으로 아주 넓은 분포를 보였으나 2.30 ~ 2.90W/mk 값이 가장 많이 나타냈다.

  • PDF

A Study on the Physical Characteristics of Grout Material for Backfilling Ground Heat Exchanger (지중 열교환기용 뒤채움재의 물리적 특성 연구)

  • Choi, Hang-Seok;Lee, Chul-Ho;Choi, Hyo-Pum;Woo, Sang-Baik
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.37-49
    • /
    • 2008
  • A geothermal heat pump system is a preferable alternative energy system in Korea because it uses the heat energy of the earth, which is environmentally friendly and inexhaustible. In order to characterize the thermal conductivity and viscosity of grout materials used for backfilling ground heat exchangers, nine bentonite grouts, one marine clay from Boryung, and cement grouts adapted in the United State have been considered in this study. The bentonite grouts indicate that the thermal conductivity and viscosity increase with the content of bentonite or filler (silica sand). In addition, material segregation can be observed when the viscosity of grout is relatively low. The marine clay turns out to be unsuitable for backfilling the ground heat exchanger due to its insufficient swelling potential. The saturated cement grouts appear to possess much higher thermal conductivity than the saturated bentonite grouts, and the reduction of thermal conductivity in the cement grouts after drying specimens is less than that in the case of the bentonite grouts. Maintaining the moisture content of grouts is a crucial factor in enhancing the efficiency of ground heat exchangers.

Evaluation of Ground Effective Thermal Properties and Effect of Borehole Thermal Resistance on Performance of Ground Heat Exchanger (지중 유효 열물성 산정 및 지중열교환기 성능에 대한 보어홀 열저항의 영향)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.32-40
    • /
    • 2012
  • Geothermal heat pump(GHP) systems use vertical borehole heat exchangers to transfer heat to and from the surrounding ground via a heat carrier fluid that circulates between the borehole and the heat pump. An Important feature associated with design parameters and system performance is the local thermal resistances between the heat carrier flow channels in the borehole and the surrounding ground. This paper deals with the in-situ experimental determination of the effective thermal properties of the ground. The recorded thermal responses together with the line-source theory are used to determine the thermal conductivity and thermal diffusivity, and the steady-state borehole thermal resistance. In addition, this paper compares the experimental borehole resistance with the results from the different empirical and theoretical relations to evaluate this resistance. Further, the performance simulation of a GHP system with vertical borehole heat exchangers was conducted to analyze the effect of the borehole thermal resistance on the system performance.

Thermal Conductive Characteristics and Basic Properties of Bentonite Grouts for the Ground Heat Exchanger of Geo-source Heat Pump (지열히트펌프 지중열교환기용 벤토나이트계 그라우트재의 열전도특성 및 기본성능)

  • Bai, Kang
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.66-72
    • /
    • 2013
  • In this study, the thermal conductive characteristics and basic properties of the nine commercial products of bentonite grouts were studied. Six of the nine products for ground heat exchanger systems are imported and others for civil engineering are domestic. The thermal conductivities of all bentonite products are nearly similar among products. The free swell indexes, viscosities and filter losses of the ground heat exchanger grouts are lower than those of the civil engineering ones. These characteristics seem to increase of the fluidity to fill the bentonite slurry to bore-hall perfectly, rather than to prevent underground water penetration. Thus, the mixtures of bentonites and sands are recommended for high thermal conduction grouts.

Thermal Conductivity Measurement of Grouting Materials for Geothermal Heat Exchanger (그라우트 재료에 따른 지중 열교환기의 열전도도에 관한 실험적 연구)

  • Lim Hyo Jae;Kong Hyoung Jin;Song Yoon Seok;Park Seong Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.364-369
    • /
    • 2005
  • An experimental study was conducted on the thermal conductivity of various grouting materials for geothermal heat exchanger which is used as a heat sink or source in the heat pump system. The grouting of the vertical heat exchanger is important for environmental and heat transfer reasons and is generally accomplished by the placement of a low permeability material into the annular space between the borehole wall and the pipes suspended in the borehole. In this study, a lab scale test apparatus was made and measured the thermal conductivity of four grouting materials. As a result, the temperature rising tendency was similar among them, but the increasing rate was different. Thus the thermal conductivity showed a maximum difference of $27\%$ among grouting materials.

Study on the heat transfer properties of raw and ground graphene coating on the copper plate

  • Lee, Sin-Il;Tanshen, Md.R.;Lee, Kwang-Sung;Munkhshur, Myekhlai;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.78-85
    • /
    • 2013
  • A high thermal conductivity material, namely graphene is treated by planetary ball milling machine to transport the heat by increasing the temperature. Experiments were performed to assess the heat transfer enhancement benefits of coating the bottom wall of copper substrate with graphene. It is well known that the graphene is unable to disperse into base fluid without any treatment, which is due to the several reasons such as attachment of hydrophobic surface, agglomeration and impurity. To further improve the dispersibility and thermal characteristics, planetary ball milling approach is used to grind the raw samples at optimized condition. The results are examined by transmission electron microscopy, x-ray diffraction, Raman spectrometer, UV-spectrometer, thermal conductivity and thermal imager. Thermal conductivity measurements of structures are taken to support the explanation of heat transfer properties of different samples. As a result, it is found that the planetary ball milling approach is effective for improvement of both the dispersion and heat carriers of carbon based material. Indeed, the heat transfer of the ground graphene coated substrate was higher than that of the copper substrate with raw graphene.

Thermal Diffusivity Evaluation of Backfilling Materials for Horizontal Ground Heat Exchanger Using Single-Probe Method (단일 탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 산정)

  • Sohn, Byong-Hu;Choi, Hang-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.356-364
    • /
    • 2011
  • Storage and transfer heat in soils is governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the evaluation results of the thermal diffusivity of soils (silica, quartzite, limestone, sandstone, granite, and two masonry soils used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities using single-probe method and (ii) use the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Combined algorithm with and improved model for the thermal conductivity of soils and the constituent equation provides accurate estimates of the soil thermal diffusivity.

Thermal Conductivity Estimation of Soils Using Coil Shaped Ground Heat Exchanger (코일형 지중열교환기를 이용한 지반의 열전도도 산정)

  • Yoon, Seok;Lee, Seung-Rae;Park, Hyunku;Park, Skhan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5C
    • /
    • pp.177-183
    • /
    • 2012
  • The use of energy pile foundation has been increased for economic utilization of geothermal energy. In particular, a coil-shaped ground heat exchanger (GHE) is preferred than conventional U-shaped heat exchanger to ensure better efficiency of heat exchange rate. This paper presents experimental results by changing different pitch spaces of spiral coils. Joomunjin sand was filled in a steel box of which the size was $5m{\times}1m{\times}1m$. Thermal response tests (TRTs) were conducted to measure the ground thermal conductivity with temperatures of circulating water using line source model and ring coil model. Experimental results and analytical solutions were compared to validate the applicability of these models. Ring coil model showed more accurate similar results with experimental data rather than line source model and cylindrical source model.

A Study on the Thermal Characteristics of Horizontal Ground Heat Exchanger using Thermal Response Test (열응답시험을 이용한 수평형 지중열교환기 열특성 연구)

  • Chang, Keun Sun;Kim, Min-Jun;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.24-30
    • /
    • 2016
  • Vertical and standing column well ground heat exchangers have mostly been installed for ground source heat pump systems (GSHP) and thermal response tests (TRT) have been applied to evaluate the thermal characteristics for these heat exchangers. In this paper, the TRT coupled with a line source method was applied to evaluate the thermal characteristics of the horizontal ground heat exchanger (HGHX). Load tests of a HGHX were also performed to examine the daily variations of the ground and fluid temperatures associated with the daily intermittent operation of GSHP. For this test, the straight HGHX (depth 2 m, length 50 m, 8 line) was installed in Ansan city. The results showed that the variations of ground thermal conductivity of HGHX during one year were relatively small with the range of $1.43{\sim}1.64W/m{\cdot}K$, and the maximum and minimum values appeared in December and May, respectively. Load tests with heat injection rate of 6.0 kW for 10 hours per day to HGHX during twelve days were performed in June, September and December, and resulted in a ground initial temperature rise of $4.31^{\circ}C$, $3.14^{\circ}C$, and $1.21^{\circ}C$ during these days, respectively.

A Study on Development of a Ground-Source Heat Pump System Utilizing Pile Foundation of a Building (건물 기초를 이용한 지중열 공조시스템의 개발에 관한 연구 (2))

  • Ryozo, Ooka;Hwang, Suk-Ho;Kentaro, Sekine;Yosuke, Shimawaki;Nam, Yu-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.155-160
    • /
    • 2005
  • To purpose of this research is to develop the numerical model for simulating performance of ground heat exchanger with high prediction accuracy. This paper describes the development of a numerical model that simulates the heat transfer between ground and circulation water in ground heat exchanger. Furthermore, we propose the estimating technique of soil properties, such as thermal conductivity, heat capacity and hydraulic conductivity, based on ground investigation. Comparison between experiment and numerical analysis based on the model developed above was conducted under the condition of the experiment in 2004. The result of analysis agreed well with the experimental result.

  • PDF