• 제목/요약/키워드: ground thermal conductivity

검색결과 160건 처리시간 0.03초

짧은 섬유상간의 접합을 가진 Silicon Carbide Web 복합재료의 분율별 열전도 거동 (Thermal Conducting Behavior of Composites of Conjugated Short Fibrous-SiC Web with Different Filler Fraction)

  • 김태언;배진철;조광연;이동진;설용건
    • 한국세라믹학회지
    • /
    • 제49권6호
    • /
    • pp.549-555
    • /
    • 2012
  • Silicon carbide(SiC) exhibits many unique properties, such as high strength, corrosion resistance, and high temperature stability. In this study, a SiC-fiber web was prepared from polycarbosilane(PCS) solution by employing the electrospinning process. Then, the SiC-fiber web was pyrolyzed at $1800^{\circ}C$ in argon atmosphere after it was subjected to a thermal curing. The SiC-fiber web (ground web)/phenolic resin (resol) composite was fabricated by hot pressing after mixing the SiC-fiber web and the phenolic resin. The SiC-fiber web composition was controlled by changing the fraction of filler (filler/binder = 9:1, 8:2, 7:3, 6:4, 5:5). Thermal conductivity measurement indicates that at the filler content of 60%, the thermal conductivity was highest, at 6.6 W/mK, due to the resulting structure formed by the filler and binder being closed-packed. Finally, the microstructure of the composites of SiC-fiber web/resin was investigated by FE-SEM, EDS, and XRD.

히트펌프용 수직형 지중열교환기의 성능에 관한 연구 (A Study on Performance of Vertical Ground Heat Exchanger for Heat Pump)

  • 장기창;정민호;윤형기;나호상;유성연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.466-469
    • /
    • 2007
  • Heat pumps are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. And a vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double n-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

불포화 지반 조건을 고려한 파일 매입형 열교환기의 수치해석 (Numerical Simulation of Ground Heat Exchanger Embedded Pile Considering Unsaturated Soil Condition)

  • 최정찬;이승래
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.213-220
    • /
    • 2010
  • This study presents a numerical simulation model of vertical ground heat exchangers, considering unsaturated hydro static ground conditions induced by the ground water table fluctuation. Heat transfer in ground and grout is modeled by a 3-D FEM transient conductive heat transfer model, where heat transfer between circulating fluid and heat exchanging pipe is treated as 1-D quasi steady state forced convective elements. To take into account the unsaturated ground condition, soil thermal conductivity and heat capacity which are dependent on the matric suction are applied to ground elements. Parametric studies considering various ground water table conditions are conducted to investigate the influence of unsaturated hydro static ground condition on the mean heat exchange rate of ground heat exchanger. Simulation results considering water table fluctuation show 60~100% of mean heat exchange rate for a saturated soil condition and 125~208% of that for a dry soil condition. Thus consideration of unsaturated soil condition is substantially recommended for more accurate design and performance evaluation for ground heat exchangers.

  • PDF

지중열전달특성 평가에 관한 해석 및 실험적 방법에 관한 연구 - 지중 열물성치 및 보어 홀 열 저항 평가 - (Study on Analytical and Empirical Methods for Assessing Geo-Heat Transfer Characteristics)

  • 박준언;백남춘
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.427-432
    • /
    • 2005
  • This study treats the advantage of in situ line source method measuring the heat transfer capacity of a borehole, using mobile equipment, to determine the thermal properties of the entire borehole system such as thermal conductivity, diffusiveity. volumetric heat capacity, and borehole thermal resistance. The results from the response test include not only the thermal properties of the ground and the borehole, but also conditions that are difficult to estimate, e,g. natural convection in the boreholes, asymmetry in the construction, etc. In this study, 1) theoretical in situ methods for assessing working fluid temperature variation in V-type PE tube have been introduced, and 2) TRTE(Thermal Response Test Equipment) has been built based on these kinds of theoretical in situ methods. Basically TRTE consists of a pump, a heater and temperature sensors for measuring the inlet and outlet temperatures of the borehole. In order to make equipment easily transportable it is set up on a small trailer. Since the response test takes above two days to execute, the test was fully automatic in recording measured data using Labview DAS(Data acquisition system) program. The test was demonstrated in the course of intensive research in this field through the one site at Ulsan city in Korea. From this kind of thermal properties test of borehole systems in situ, the design of the borehole system can be optimized regarding the total geological, hydro-geological and technical conditions at the location.

  • PDF

Mitigating the Urban Heat Island Phenomenon Using a Water-Retentive Artificial Turf System

  • Tebakari, Taichi;Maruyama, Tatsuya;Inui, Masahiro
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.91-100
    • /
    • 2010
  • To investigate the thermal properties of a water-retentive artificial turf system (W-ATS), we estimated hydrologic parameters including thermal conductivity, heat capacity, and surface albedo for both the W-ATS and natural grass. We used a model experiment to measure surface temperature and evaporation for both the W-ATS and natural grass. We found that the W-ATS had lower thermal conductivity than natural grass did, and it was difficult for the W-ATS to convey radiant heat to the ground. Compared to natural grass, the W-ATS also had lower heat capacity, which contributed to its larger variation in surface temperature: the W-ATS had higher surface temperatures during daytime and lower surface temperatures during nighttime. The albedo of the W-ATS was one-quarter that of natural grass, and reflected shortwave radiation from the W-ATS surface was lower than that from the surface of natural grass. These results indicate that the W-ATS caused the soil temperature to increase. Furthermore, evaporation from the W-ATS was one-quarter the value of evapotranspiration from natural grass.

  • PDF

고준위폐기물 처분시설의 압축 벤토나이트 완충재의 열전도도 추정 (A Prediction of Thermal Conductivity for Compacted Bentonite Buffer in the High-level Radioactive Waste Repository)

  • 윤석;이민수;김건영;이승래;김민준
    • 한국지반공학회논문집
    • /
    • 제33권7호
    • /
    • pp.55-64
    • /
    • 2017
  • 심층 처분방식은 고준위폐기물을 처분하기 위한 가장 적합한 대안으로 고려되어지고 있다. 심층 처분시설은 지하 500~1,000m 깊이의 암반층에 설치되며 심층 처분시스템의 구성 요소로는 처분용기, 완충재, 뒷채움 및 근계 암반이 있다. 이 중 완충재는 심층 처분시스템에 있어 매우 중요한 역할을 한다. 완충재는 지하수 유입으로부터 처분용기를 보호하고, 방사성 핵종 유출을 저지한다. 처분용기에서 발생하는 고온의 열량이 완충재로 전파되기에 완충재의 열적 성능은 처분시스템의 안정성 평가에 매우 중요하다고 할 수 있다. 따라서 본 연구에서는 국내 경주산 압축 벤토나이트 완충재에 대한 열전도도 추정 모델을 개발하고자 하였다. 압축 벤토나이트 완충재의 열전도도는 비정상 열선법을 이용하여 다양한 함수비와 건조밀도에 따라 측정하였으며, 총 39개의 실험 데이터를 토대로 회귀분석을 이용하여 경주 압축 벤토나이트의 열전도도 추정 모델을 제시하였다.

지열냉난방시스템 수직형 지중열교환기 그라우트의 열적 특성에 관한 연구 (A Study on Thermal Conductivity Properties of Ground Heat Exchangers for GSHP systems)

  • 백성권;전중규;안형준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.546-549
    • /
    • 2007
  • 지열 냉난방 시스템의 설계는 냉난방 공간의 크기에 따라 필요한 부하를 계산하여 설계하게된 다. 설계 부하를 충분히 소화할 수 있는 지열교환기의 길이와 보어홀의 깊이 및 개수는 지반의 열적 특성에 크게 좌우된다. 열전도율이 큰 지반일수록 지열교환기 내의 열 흡수 및 소산이 효과적으로 이루어져 지열교환기의 길이도 상대적으로 짧아질 수 있다. 즉, 효율적이고 정확한 설계를 하기 위해서는 지반, 암반 및 지중열교환기의 물리적 특성에 따른 열적 특성을 설계자는 미리 숙지하여야 한다. 현재 국내에서 수직 밀폐형 지중열교환기의 그라우트로 벤토나이트를 가장 많이 사용하고 있으나, 해외의 경우 지중 조건에 따라 시멘트 또는 벤토나이트를 적절히 선택하여 시공하고 있다. 이는 벤토나이트의 특성상 적용 조건이 제약을 받기 때문이며, 특히 지하수가 존재하지 않을 경우 사용이 사실상 불가능하다. 국내에서 이에 대한 충분한 연구는 아직 이루어지지 않았으며, 시멘트 그라우트를 사용하기 위한 물리적, 열적 특성에 대한 연구가 필요한 시점이라 판단하여 본 연구를 수행하였다. 시멘트 그라우트의 경우 수화반응이 일어나는 초기의 건조수축을 최소화하는 배합비로 물성을 구성하였으며, 벤토나이트는 일반 현장 시공 비율을 사용하였다. 열전도율은 첫째 실내 시험으로 시멘트 그라우트에 대한 열판시험법과 벤토나이트 그라우트에 대한 탐침시험법으로 수행하여 구하였으며, 두 번째 방법인 현장 시공으로 직접 현장열응답시험을 수행하여 그라우트 간의 열적 특성을 비교하였다. 또한 기존 시멘트그라우트의 열적 특성을 개량한 코오롱건설에서 개발한 시멘트 그라우트에 대한 열적 거동도 기존 타 그라우트의 열적 거동과 비교하였으며, 개발 제품의 성능이 상당히 우수함을 알 수 있었다.

  • PDF

건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립 (Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture)

  • 황민규;조우진;김강수
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

절리 및 지하수가 암반의 열전파 특성에 미치는 영향 (The Effect of Rock Joints and Ground Water on the Thermal Flow through Rock Mass)

  • 박연준;유광호;신희순;신중호
    • 터널과지하공간
    • /
    • 제12권3호
    • /
    • pp.220-228
    • /
    • 2002
  • 절리암반에서의 열유동을 수치해석적으로 분석하였다. 1차원 모델 해석을 통하여 한 조의 절리군이 열전도에 미치는 영향을 비교 분석하고, 이론해와 비교하였다. 절리 내에 물이 전혀 없는 경우, 절리는 열 차단제의 역할을 하며 정상상태에서도 온도의 불연속이 관찰되었다. 따라서 암반 내 존재하는 절리가 완전 건조상태인 경우에는 개별적인 절리의 열차단 효과를 일일이 고려하여야 정확한 결과를 얻을 수 있다 그러나 절리 내에 물이 부분적으로 혹은 완전히 포화된 경우에는 열차단 효과가 현저히 줄어들어 온도 분포에 미치는 영향이 현저히 감소하였다. 따라서 절리 암반을 통한 열전도는 암반을 무결암의 열적 성질과 불연속면의 열적 성질을 포함한 열적 이방성 연속체로 가정함으로써 가능하다 할 수 있다. 절리의 포화 정도가 증가할수록 절리가 열유동에 미치는 영향이 감소하므로 암반의 열전달 특성은 등방에 가까워지며, 따라서 복잡한 모델을 이용한 해석보다는 현지 암반의 열물성을 정확히 측정하는 것이 더욱 중요함을 알 수 있었다.

얼음벽 형성에 대한 지하수 흐름의 영향 (Effect of Groundwater Flow on Ice-wall Integrity)

  • 신호성;김진욱;이장근
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.43-55
    • /
    • 2018
  • 인공동결공법은 일시적으로 지반의 강성을 높이고 투수계수를 낮추는 지반개량공법으로 지반에 적용가능하다. 하지만, 지하수 흐름과 지반의 불균질성은 동결구근 형성을 불확실하게 하여 공법에 대한 신뢰성을 저해한다. 동결지반 대한 열-수리 유한요소 해석 프로그램을 이용하여, 인공동결공법에서 지하수 흐름속도와 지반의 층상 비균질이 얼음벽 형성을 미치는 영향을 분석하였다. 지하수의 흐름은 원형의 동결구근을 원형에서 타원형을 변형시키며 얼음벽의 완성 소요시간을 증가시킨다. 기존의 이론식은 인접 동결구근의 열적 상호작용을 무시하여, 얼음벽의 완결시간과 한계유속을 과대 평가하였다. 수치해석 결과를 바탕으로 수정식을 제시하였으며 무차원 얼음벽 완결시간에 대한 제안식을 검증하였다. 층상의 비균질 지반에서 투수계수가 큰 지층의 두께와 상대적인 투수계수비는 얼음벽 완결시간과 한계 유속에 중요한 인자인 것으로 나타났다.