화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구 (A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession)

  • 정병선;김응식;박종열
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

심매설 접지봉의 위치결정을 위한 대지구조 분석 방법들의 비교분석 (Comparison Analysis of Soil Structure Methods for Deciding the Position of a Deeply Driven Ground Rod)

  • 엄주홍;조성철;이태형;이복희
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.37-45
    • /
    • 2007
  • 최근 뇌보호용 접지시스템 심매설 봉전극을 사용하는 경우가 늘고 있다. 심매설 봉전극의 경우에는 수직으로 깊게 봉전극을 시설하기 때문에 메시그리드 전극에 비해 장소의 제약을 덜 받는 장점이 있지만 국지적인 대지저항률에 의해 접지임피던스가 크게 변동하므로 설계시에 세밀한 대지구조의 분석이 필요하다. 기존의 Wenner법에 의한 대지저항률 측정은 널리 사용되는 방법이지만 국지적인 대지저항률의 변화를 알아내기가 불가능하였고 또한 겉보기 대지저항률로 측정결과가 나타나므로 정확한 깊이를 예측하기가 어렵다. 따라서 본 연구에서는 96채널 측정설비를 이용하여 대지구조를 2-D 이미지로 분석하였으며, 뇌보호용 심매설 전극을 효과적으로 설계하기 위해 국지적인 대지저항률 변동 및 대지층 깊이의 분석을 시도하였다. 대지저항률의 2-D 이미지 분석은 Wenner alpha법, Dipole-dipole법, Schlumberger법을 사용하였으며, 분석결과를 토대로 기존의 Wenner 1-D법으로 측정한 결과를 CDEGS로 분석한 대지구조와 비교하였다.

거리·시간 측정에 의한 고정도 타행시험법: II. 단거리 방법의 개발 및 시험 (High-Accuracy Coastdown Test Method by Distance-Time Measurement: II. Development of a Short Distance Method and its Evaluation)

  • 허남건;안이기
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.1-8
    • /
    • 1995
  • In the companion paper of the present paper, a coast down test method to determine the resistance forces on running vehicle based on the distance-time measurement was explained along with the suggestions to improve its accuracy and testing methodology. In the present paper some of the suggestions discussed previously are implemented and actually road tested to see the applicability of the improved method(short distance method) in the field. From the results. it is shown that the short distance method which requires only 600m long proving ground road gives at least comparable results on the accuracy compared to the original S-t method which requires 2000m. It is hoped that the present method be further refiend to give more accurate results.

  • PDF

접지그리드의 접지임피던스 측정 기법 (Measurement method of ground impedance for the grounding grid)

  • 이복희;최종혁;최영철;유재덕;백영환;김동성;신희경;유양우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

지반굴착에 소요되는 전기식모터의 전류저항값 변화에 관한 연구 (A Study of Change in Current Resistance Value of Electric Motor Requied for Ground Dilling)

  • 서동남;정상훈;이상현;신진섭;최상호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.385-386
    • /
    • 2023
  • In this application study, field pilot tests were performed to evaluate the validity of a proposed formula between the exerted electrical energy and SPT N-value based on the result of the basic study. Measurement sensors and recording system were developed to obtain exerted motor current and drilling depth in a field. By using the correlation formula proposed in the basic study, the measured motor current and boring speed were applied to predict SPT N-value and the predicted N-values were compared to SPT N-value of site exploration. From the comparisons it is verified that the exerted electrical energy to bore ground might be used to predict SPT N-value and pile tip location.

  • PDF

석회암공동 분포지역에서의 터널 시공사례 (A Case Study on Construction of Tunnel at Limestone Cavity Site)

  • 김시격;강인섭;김용하;윤일병;문훈기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.66-75
    • /
    • 2006
  • As construction for road tunnel is increasing, various geotechnical conditions can be faced during the construction stage. Especially, if the tunnel is located in limestone area, many kinds of site investigations such as in-situ boring, electrical resistance survey, TSP(Tunnel Seismic Prediction) and etc., are conducted before and during the construction. By conducting these preliminary tests, location, size, and filling materials in limestone cavities can be approximately estimated. Once some cavities which can be harmful for tunnel safety are predicted, methods for ground reinforcement and tunnel excavation, corresponding those ground conditions, have to be established and verified by measurement data and numerical analysis. If necessary, invert lining should be also considered. In this paper, by studying some cases of tunnels constructed in limestone area, predicted problems during construction and rational countermeasures for those are presented.

  • PDF

대규모 접지전극 망의 접지성능 평가를 위한 겉보기저항곡선의 해석에 관한 연구 (A study on the Interpretation Technique of Fall-Of-Potential Curve for Grounding Performance Evaluation of a Large Grounding Electrode Network)

  • 최종기;유희영;이동일;정길조;김경철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.49-54
    • /
    • 2005
  • 접지저항의 측정은 접지극의 성능을 정량적으로 평가하는 가장 일반적인 방법이며, 여러 측정방법 중 전위강하 법은 대형 접지극의 저항측정에 많이 이용되는 방법이다. 그러나 접지극의 크기에 비례하여 측정선 길이도 길어져야 하므로, 대규모 접지전각의 경우 현장여건상 충분한 길이의 측정선을 펼치기가 곤란한 경우가 있을 수 있다. 본 논문에서는 여러 개의 접지망이 상호 연결되어 대규모의 접지극 네트워크를 형성하고 있어 충분한 길이의 전위강하법 측정선을 펼치는 것이 현실적으로 어려운 경우에 전위강하법 측정결과의 해석방법을 제시한다. 사례연구로서 상부댐 접지극과 약 2(km) 떨어져 있는 스위치야드 접지극이 상호 연결된 대형 접지극망에서 전위강하법 측정곡선 및 해석사례를 기술하였다.

3가지 접지방식에 대한 접지특성비교 (The Comparison on Grounding Characteristics for 3 Grounding Systems)

  • 신동호;김용;백수현;이은영;김필수;조대훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.289-297
    • /
    • 2000
  • This paper presents a comparison on the resistance and characteristics of transient response of grounding systems under surge currents using frequency domain electromagnetic field analysis software package and field test. Analysis is done by computer model, based on electromagnetic field theory approach, that accurately takes into account frequency dependent characteristics of the system. The transient performance of three grounding systems is analyzed by comparison of frequency dependent impedance and the maximal transient GPR. A double exponential lighting surge current is injected at one corner of the grounding systems. The transient GPRs a rod grounding systems are higher than mesh or electrolytic grounding systems. Af field test, the results of resistance measurement and time-variant of ground resistance slightly reduce electorlytic grounding systems less than rod and mesh grounding systems.

  • PDF

Theoretical resistance in cylindrical electrodes with conical tip

  • Hong, Chang-Ho;Kim, Jin-Seop;Chong, Song-Hun
    • Geomechanics and Engineering
    • /
    • 제30권4호
    • /
    • pp.337-343
    • /
    • 2022
  • The electrical resistivity method is a well-known geophysical method for observing underground conditions, (such as anomalies) and the properties of soil and rock (such as porosity, saturation, and pore fluid characteristics). The shape of electrodes used in an electrical resistivity survey depends on the purpose of the survey and installation conditions. Most electrodes for field applications are cylindrical for sufficient contact with the ground, while some are conically sharpened at their tips for convenient penetration. Previous study only derived theoretical equations for rod-shaped electrodes with spherical tips. In this study, the theoretical resistance for two cylindrical electrodes with conical tips is derived and verified experimentally. The influence of the penetration depth and tip on the measurement is also discussed.

그라운드 방사체를 활용한 고효율의 소형 안테나 (A Small Antenna of High Radiation Efficiency Employing a Ground Radiator)

  • 최형철;이형진;박범기;장진혁;김형동
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.135-143
    • /
    • 2012
  • 본 논문은 안테나 구조 없이 리액티브 소자 만을 이용하여 단말기 그라운드를 방사체로 활용하는 방법을 소개한다. 안테나의 특성은 블루투스 대역에서 동일 그라운드 면적($40{\times}20mm^2$)을 가지는 미앤더 IFA와 비교하여 분석하였다. 시뮬레이션 및 측정을 통해 캐패시터 소자 만을 이용한 안테나가 가장 높은 방사 효율을 나타내는 것으로 판명되었다. 이는 안테나의 인덕턴스가 높을수록 그라운드의 방사 저항이 감소하고, 캐패시터의 손실 저항이 인덕터 또는 IFA보다 낮기 때문이다. 높은 방사 효율에도 불구하고 제안하는 안테나의 면적($5{\times}2.5mm^2$)은 IFA의 면적($12{\times}2.5mm^2$)의 반 이하이다.