• Title/Summary/Keyword: ground freezing

Search Result 154, Processing Time 0.026 seconds

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.

Effects of Freezing of Gait on Spatiotemporal Variables, Ground Reaction Forces, and Joint Moments during Sit-to-walk Task in Parkinson's Disease

  • Park, Hwayoung;Youm, Changhong;Son, Minji;Lee, Meounggon;Kim, Jinhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • Objective: This study aimed to analyze the effects of freezing of gait on spatiotemporal variables, ground reaction forces (GRFs), and joint moments during the sit-to-walk task at the preferred and maximum speeds in patients with Parkinson's disease (PD). Method: The subjects were classified by a neurologist into 12 freezers, 12 non-freezers, and 12 controls. Sit-to-walk parameters were measured during three repetitions of the task in a random order at the preferred and maximum possible speeds. Results: In the sit-to-walk task at the preferred speed, the freezers and non-freezers exhibited a higher peak anterior-posterior GRF (p<0.001) in the sit-to-stand phase and lower step velocity (p<0.001), step length (p<0.001), and peak anterior-posterior GRF (p<0.001) in the first-step phase than the controls. The freezers had higher peak anterior-posterior GRF (p<0.001) and peak moment of the hip joint (p=0.008) in the sit-to-stand phase than the non-freezers. In the sit-to-walk phase at the maximum speed, the freezers and non-freezers had lower peak moment of the hip joint (p=0.008) in the sit-to-stand phase than the controls. The freezers and non-freezers displayed lower step velocity (p<0.001) and peak anterior-posterior GRF (p<0.001) in the first-step phase than the controls. The freezers showed higher peak moments of the hip joint in the sit-to-stand phase than the non-freezers (p=0.008). Conclusion: The PD patients had reduced control ability in sit-to-stand motions for efficient performance of the sit-to-walk task and reduced performance in the sit-to-walk task. Furthermore, the freezers displayed reduced control ability in the sit-to-stand task. Finally, the PD patients exhibited a lower ability to control dynamic stability with changes in speed than the controls.

Evaluation on the Applicability of Comet Assay for the Identification of Gamma-irradiated Frozen Beef Cut, Ground Beef and Tteokgalbi (감마선처리 냉동 우육, 분쇄우육 및 떡갈비의 판별을 위한 Comet assay의 적용성 평가)

  • Jong-Heum Park;Jae-Kyung Kim;Beom-Seok Song
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.257-264
    • /
    • 2023
  • This study was conducted to evaluate the applicability of the Comet assay, which is widely used for the identification of irradiated meats, to detect irradiated beef cut, ground beef, and Tteokgalbi during freezing storage. Gamma-irradiation significantly increased the DNA damage in frozen beef cut and ground beef samples. Among those, DNA nuclei of samples irradiated with absorbed doses of 1kGy or more showed typical comet-shaped damage, convincing that the samples were irradiated. Meanwhile, DNA nuclei in non-irradiated beef cut and ground beef samples were also damaged according to storage time. In particular, since the damage of DNA nuclei in the non-irradiated samples frozen for three months was similar to that of samples irradiated with a dose of 0.5 kGy, it was considered difficult to detect whether these samples were irradiated by Comet assay analysis. Likewise, gamma-irradiation of Tteokgalbi increased DNA damage. However, significant damage to DNA nuclei was observed even in the non-irradiated samples. Therefore, the application of the analysis method to determine whether the Tteokgalbi sample was irradiated was not appropriate. In conclusion, these results suggest that Comet assay could be limitedly applied only to fresh meat with a short storage period and minimal processing.

Evaluation on Thermal Performance of Thermosyphon by Numerical Analysis (열사이펀의 열성능 산정을 위한 수치해석 연구)

  • Jang, Changkyu;Choi, Changho;Lee, Jangguen;Lee, Chulho
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.9
    • /
    • pp.57-66
    • /
    • 2014
  • The ground in cold region consists of active and permafrost layers. The active layer at the unstable state may cause ground corrosion and uplift, when the temperature of frozen ground increases due to seasonal changes. The thermosyphon is one of the stabilization methods to maintain the ground stability in the frozen ground. The thermosyphon is a closed two-phase convection device that extracts heat from the ground and discharges it into the atmosphere. In this study, ground freezing experiment using a thermosyphon and simulated ground with the isolation material was conducted to evaluate the thermal performance of the thermosyphon. In order to consider the thermal performance of the thermosyphon, commercial numerical program (TEMP/W) was adopted. Likewise, the thermal performance of thermosyphon and thermal properties of ground were applied in the numerical model. In a series of comparisons with experiment results and numerical study, thermal performance of thermosyphon can be evaluated.

A Study for Adfreeze Bond Strength Developed between Weathered Granite Soils and Aluminum Plate (동결된 화강풍화토와 알루미늄판 접촉면에서 발현되는 동착강도 측정 연구)

  • Lee, Joonyong;Kim, Youngseok;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.12
    • /
    • pp.23-30
    • /
    • 2013
  • Bearing capacity of pile is governed by only skin friction in frozen ground condition, while it is generally governed both by skin friction and end bearing capacity in typically unfrozen ground condition. Skin friction force, which arises from the interaction between pile and frozen soils, is defined as adfreeze bond strength, and adfreeze bond strength is one of the most important key parameters for design of pile in frozen soils. Many studies have been carried out in order to analyze adfreeze bond strength characteristics over the last fifty years. However, many studies for adfreeze bond strength have been conducted with limited circumstances, since adfreeze bond strength is sensitively affected by various influence factors such as intrinsic material properties, pile surface roughness, and externally imposed testing conditions. In this study, direct shear test is carried out inside of large-scaled freezing chamber in order to analyze the adfreeze bond strength characteristics with varying freezing temperature and normal stress. Also, the relationship between adfreeze bond strength and shear strength of the frozen soil obtained from previous study was analyzed. The coefficient of adfreeze bond strength was evaluated in order to predict adfreeze bond strength based on shear strength, and coefficients suggested from this and previous studies were compared.

A study on freeze-thaw evaluation criteria for road tunnels considering climate characteristics (국내 기후특성을 고려한 도로터널의 동결-융해 평가기준 연구)

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.121-133
    • /
    • 2020
  • Globally, the frequency and intensity of abnormal climate events are increasing. Since this can directly damage lives and property, it is important to establish and implement an appropriate maintenance strategy in response to abnormal weather. Facilities built in cold regions where cold wave or heavy snow occurs frequently can be more damaged by freeze-thaw than facilities located in other regions. However, there are no clear criteria for quantitatively identifying the damage of freeze-thaw and how to cope with it. Therefore, based on the results of indoor freezing tests, the freezing conditions considering regional climate characteristics were selected as one day at -14℃, two days at -7℃ or three days at -5℃. As a result, it was confirmed that they were in the freeze-thaw environment in order of Daegwallyeing (8.3 times), Cheorwon (5.3 times) and Taebeak (4.9 times) in Gangwon region. Through this study, the evaluation criteria of freeze-thaw of road tunnels were newly proposed. The freeze-thaw evaluation criteria of the road tunnel presented in this study can be used for the quantitative evaluation and maintenance strategy of tunnels in cold regions.

Prediction of Adfreeze Bond Strength Using Artificial Neural Network (인공신경망을 활용한 동착강도 예측)

  • Ko, Sung-Gyu;Shin, Hyu-Soung;Choi, Chang-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.71-81
    • /
    • 2011
  • Adfreeze bond strength is a primary design parameter, which determines bearing capacity of pile foundation in frozen ground. It is reported that adfreeze bond strength is influenced by various affecting factors like freezing temperature, confining pressure, characteristics of pile surface, soil type, etc. However, several limited researches have been performed to obtain adfreeze bond strength, for past studies considered only few affecting factors such as freezing temperature and type of pile structures. Therefore, there exists a limitation of estimating the design parameter of pile foundation with various factors in frozen ground. In this study, artificial neural network algorithm was involved to predict adfreeze bond strength with various affecting factors. From past five studies, 137 data for various experimental conditions were collected. It was divided by 100 training data and 37 testing data in random manner. Based on the analysis result, it was found that it is necessary to consider various affecting factors for the prediction of adfreeze bond strength and the prediction with artificial neural network algorithm provides enough reliability. In addition, the result of parametric study showed that temperature and pile type are primary affecting factors for adfreeze bond strength. And it was also shown that vertical stress influences only certain temperature zone, and various soil types and loading speeds might cause the change of evolution trend for adfreeze bond strength.

A Study on the Effect of Pile Surface Roughness on Adfreeze Bond Strength (말뚝표면 거칠기에 따른 동착강도 변화에 관한 연구)

  • Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.79-88
    • /
    • 2011
  • Adfreeze bond strength develops upon freezing of pore water within soil and at foundation surface. It has been reported that various factors like temperature, soil type, and pile surface roughness affect adfreeze bond strength. Especially, pile surface roughness has been considered as a primary factor to design pile foundation in frozen ground. It has usually been estimated with fixed correction factors for pile materials. However, even if the pile foundation material is the same, the surface roughness could vary depending on the production circumstances. In this study, laboratory test was carried out to quantitatively analyze the effects of surface roughness on the adfreeze bond strength, and fractal dimension was used as a measure for surface roughness. Test results showed that adfreeze bond strength increased with decreasing temperature, increasing vertical stress and surface roughness. The adfreeze bond strength varies sensitively with surface roughness in the early freezing section of $-2^{\circ}C$, but its sensitivity decreased in the temperature ranging between $-2^{\circ}C$ to $-5^{\circ}C$. The results conclude that the roughness highly affects the frictional resistance of pile surface in frozen ground; however, the roughness does not affect considerably when the temperature drops below about $-2^{\circ}C$.

Analysis of Temperature Change of Tunnel Lining with Heating Element (발열체가 적용된 터널 라이닝 내부 및 배면의 온도변화 분석)

  • Jin, Hyunwoo;Kim, Teasik;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.5-12
    • /
    • 2017
  • The damage of the tunnel lining on the cold regions can be represented by cracks and leaks caused by freezing of ground water. However, domestically, the relevant construction guidelines are not provided so far. Thus, in this research, the mechanical behavior and thermal conductivity of designated tunnel area are measured using instrumentation system installed in the lining concrete inside tunnels in order to analysis their behavior with regard to temperature variations. Previous research mainly focused on the effect of temperature on the tunnel lining based on the air and initial ground temperature at urban regions. Thus, this study analyzes effects of air temperature and initial ground temperature of designated tunnel area at the cold regions. The temperature of the groundwater at the backfill of the tunnel lining are analyzed to evaluate the heating element. Numerical analyses are performed to evaluate the heating element with regard to the various initial ground temperatures.

The Study of Appropriate Mixture Ratio and Replacement Ratio of Bottom Ash Mixture Compaction Pile in Soft Ground (연약지반에서 저회혼합다짐말뚝의 적정 혼합비 및 치환율 산정에 관한 연구)

  • Do, Jong Nam;Chu, Ick Chan;Chae, Hwi Young;Chun, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.139-147
    • /
    • 2012
  • In this study, various laboratory tests using bottom ash, which has similar engineering properties with sand, were conducted in order to solve the problem of clogging in granular compaction pile and to address sand supply and demand. In particular, testing was performed to help reduce clogging and minimize voids in a crushed stone compaction pile constructed in soft ground. Based on compaction tests and large diameter direct shear tests, an optimum mixing ratio was determined to be 80:20 (crushed stone to bottom ash) because an 80:20 mixing ratio showed the highest shear strength. Test results showed that as the bottom ash content increased above 20%, internal friction angle decreased. Another test method showed freezing and thawing had little effect when the replacement ratio was over 40%. Therefore, bottom ash mixed compaction piles in soft ground are most economical at a 40% replacement ratio.