• 제목/요약/키워드: greenhouse gas emission factor

검색결과 134건 처리시간 0.026초

철도수송부문 온실가스 배출 요인 분해분석 (Decomposition Analysis on Greenhouse Gas Emission of Railway Transportation Sector)

  • 이재형
    • 한국기후변화학회지
    • /
    • 제9권4호
    • /
    • pp.407-421
    • /
    • 2018
  • In this paper, I analyze the GHG (greenhouse gas) emission factor of the domestic railway transportation sector using the LMDI (Log Mean Divisia Index) methodology. These GHG factors are the emission factor effect, energy intensity effect, transportation intensity effect, and economic activity effect. The analysis period was from 2011 to 2016, and the analysis objects were an intercity railway, wide area railway, and urban railway. The results show that the GHG emission of railway transportation sector decreased during these 6 years. The factors decreasing the GHG emission are the emission factor effect, energy intensity effect, and transportation intensity effect, while the factor increasing the GHG emission is the economic activity effect.

국내 마그네슘 생산공정의 온실가스 배출량 산정 및 감축방안 연구 (A Study on the Greenhouse Gas Emission and Reduction Measures of Domestic Magnesium Production Process)

  • 김경남;임진아;유경선
    • 한국기후변화학회지
    • /
    • 제5권3호
    • /
    • pp.219-230
    • /
    • 2014
  • In this study, greenhouse gas emission of magnesium industry was estimated and the reduction potential of the greenhouse gas emission was evaluated with reduction technologies. Default value of IPCC guideline was used to calculate the greenhouse gas emission and $SF_6$ alternatives were considered in reduction potential. Import of magnesium ingot was 22,806 ton in 2013, which will be expected to increase to 81,700 ton with 20% rate in 2020. Magnesium ingot was consumed to produce magnesium alloy in diecasting process. Recently, commercial production of crown magnesium and magensium plate began. Based on ingot consumption, $CO_2$ emission of domestic magnesium industry was estimated to 504,000 ton, which is about 0.79% of domestic industrial emissions. Reduction potential of diecasting process was estimated to 489,320 ton by changing SF6 to alternative gases such as HFC-134a, Novec-612. Emission factor of Tier 3 level should be developed to enhance the accuracy of greeenhouse gas emission of magnesium industry.

국가 온실가스 인벤토리 축산부문 작성을 위한 온실가스 배출계수 개발 현황에 관한 연구 (A Research on the Status of Greenhouse Gas Emission Factors from Livestock Sector to Create a National Greenhouse Gas Inventories)

  • 이진의;이현주;박규현;최병양;라창식
    • 한국축산시설환경학회지
    • /
    • 제17권sup호
    • /
    • pp.21-34
    • /
    • 2011
  • In this study, researches on the development of country specific greenhouse gas measurement and sampling methods from the livestock sector were reviewed. Research on greenhouse gas emission factors was started in early 2000 but was not actively involved in the development of livestock sector based emission factor: since 2009, works are underway for the development of livestock sector based emission factor. Most of the research on greenhouse gas emission in the field of animal studies were done by National Institute of Animal Science, because of the uniqueness of the research laboratories. Methods of emission measurement are still not internationally certified and therefore, measurement and sampling methods for Korea livestock sector are being studied, consulting the worldwide research trends. Flux chamber method are commonly using in Korea for green house gas emission factors measurement. In recent years, continuous measurement of the microclimate was introduced to measure greenhouse gases from livestock manure storage facilities and the micrometeorology method should be adapted as recommended by Intergovernmental Penal on Climate Change (IPCC) Guideline.

온실가스 배출량 산정 방법에 따른 N2O 배출량 비교 (Comparison of N2O Emissions by Greenhouse Gas Emission Estimation Method)

  • 강소영;조창상;김승진;강성민;윤현기;전의찬
    • 한국기후변화학회지
    • /
    • 제6권3호
    • /
    • pp.175-184
    • /
    • 2015
  • In this study GC and PAS were used to calculate $N_2O$ concentration of exhaust gas from Wood Chip combustion system. Fuel supplied to the incinerator was collected and analyzed and then the analysis result was used to calculate $N_2O$ emissions. Tier 3 and Tier 4 Method were used to calculate the $N_2O$ emissions. Plant's Specific emission factor of $N_2O$ by Tier 3 Method was 0.35 kg/TJ, while default emission factor of Wood?Wood Waste proposed by 2006 IPCC G/L was 4 kg/TJ. So the $N_2O$ emission factor of this study was 3.65 kg/TJ lower compared to the IPCC G/L. The total emissions calculated by Plant's specific emission factor was 4.22 kg during the measuring period, but by Tier 4 Method it was 7.88 kg. This difference in emissions was caused by the difference of continuous measuring and intermittent sampling. It would be necessary to apply continuous measuring to calculate emissions of $Non-CO_2$ gas whose the density distribution is relatively high. However currently, according to the target management guideline of greenhouse gas and energy, the continuous measuring method to calculate greenhouse gas emission is applied only to $CO_2$. Therefore for reliable greenhouse gas emission calculation it would be necessary to apply continuous measuring to calculate $Non-CO_2$ gas emission.

하수슬러지 소각장의 온실가스 배출계수 개발 (Development of Greenhouse Gas Emission Factors from Sewage Sludge Incinerator)

  • 김승진;강성민;강소영;이정우;사재환;박성진;전의찬
    • 한국기후변화학회지
    • /
    • 제5권3호
    • /
    • pp.209-218
    • /
    • 2014
  • In this study, the researchers have developed the greenhouse gas emission coefficients targeted at sewage sludge incineration plants that treat sewage sludge by incineration. Among the gases emitted from the sewage sludge incineration plants, the greenhouse gases showed concentrations of 6.84% for $CO_2$, 4.51 ppm for $CH_4$, and 86.34 ppm for $N_2O$; calculated into greenhouse gas emission coefficients, these gave $276.06kg\;CO_2/ton$, $0.0066kg\;CH_4/ton$, and $0.35kg\;N_2O/ton$. As the result of calculating the greenhouse gas emission quantity in sewage sludge incineration plants using the greenhouse gas emission coefficients, the gross greenhouse gas emission was $84.63ton\;CO_2\;eq./day$, and the net emission was $23.90ton\;CO_2\;eq./day$; this was $37.52ton\;CO_2\;eq./day$ less than the net greenhouse gas emission that was calculated using the standard values of IPCC, which was $61.42ton\;CO_2\;eq./day$. This difference is probably because unlike the standard values of IPCC, the greenhouse gas emission coefficients of this study reflected the special properties of subject facilities. Thus, it is thought that emission coefficient research on the facilities that deviated from the standard values of IPCC should continue to achieve the development of national greenhouse gas coefficient that reflects the special properties of Korea.

광물산업의 국가온실가스배출계수 정량·평가항목 가중치에 관한 연구 (A Study on the Quantitative and Evaluation Weights of National Greenhouse Gas Emission Factors in the Mineral Industry)

  • 윤영중;조창상;전의찬
    • 한국기후변화학회지
    • /
    • 제9권1호
    • /
    • pp.81-90
    • /
    • 2018
  • "The Framework Act on Low-Carbon Green Growth" specifies the requirements for the development and verification of emission factors for establishing reliable national greenhouse gas statistics. The scope of the regulations covers the development and validation of energy, industrial processes, solvents and other product use, agriculture, land use, land use change and emission and absorption coefficients of the forestry and waste sector as defined in the 1996 IPCC Guideline and GPG 2000, The minerals sector to be covered in this study belongs to industrial processes. As a representative method for quantifying and evaluating GHG emission factors, there are emission grade quality grading and DARS (Data Rating Rating System) in the 'Procedures for Preparing Emission Factor Documents (1997)' reported by US-EPA. However, the above two methods are not specific and comprehensive, and lack the details for accurate emission factor verification. Therefore, there is a need for a method for verifying and quantifying certified greenhouse gas emission factors that reflects characteristics of each industry sector in Korea and accord with IPCC G/L and GHG target management. In this study, we conducted a weighted study on quantitative and evaluation lists of emission factor using questionnaires to develop a more accurate methodology for quantifying national greenhouse gas emission factors in the mineral sector. Quantification and evaluation of emission factor are classified into essential verification and quality evaluation. The essential verifications are : administrative compatibility, method of determining emission factors, emission characteristics, sampling methods and analysis methods, representativeness of data. The quality evaluations consisted of the quality control of the data, the accuracy of the measurement and analysis, the level of uncertainty, not directly affect the emission factor, but consisted of factors that determine data quality.

연료와 CO2 농도분석을 이용한 아역청탄 화력발전소의 온실가스 배출계수 개발 (Development of CO2 Emission Factor by Fuel and CO2 analysis at Sub-bituminous Fired Power Plant)

  • 전의찬;사재환
    • 한국환경보건학회지
    • /
    • 제36권2호
    • /
    • pp.128-135
    • /
    • 2010
  • The main purpose of this study was to develop the greenhouse gas emission factor for power plant using sub-bituminous coal. In Korea, Fired power plant are a major source of greenhouse gases within the fossil fuel combustion sectors, thus the development of emission factors is necessary to understand the characteristics of the national specific greenhouse gas emission and to develop nation specific emission factors. These emission factors were derived from the $CO_2$ concentrations measurement from stack and fuel analysis of sub-bituminous coal. Caloric value of sub-bituminous coal used in the power plants were 5,264 (as received basis), 5,936 (air-dried basis) and 6,575 kcal/kg (dry basis). The C emission factors by fuel analysis and $CO_2$ concentration measurement was estimated to be 26.7(${\pm}0.9$), 26.3(${\pm}2.8$)tC/MJ, respectively. Our estimates of C emission factors were comparable with IPCC default value.

생활폐기물 특성 분석 및 소각시설의 CO2 배출량 평가 (Property Analysis of Municipal Solid Waste and Estimation of CO2 Emissions from Waste Incinerators)

  • 김병순;김신도;김창환;이태정
    • 한국대기환경학회지
    • /
    • 제26권6호
    • /
    • pp.657-665
    • /
    • 2010
  • Carbon dioxide ($CO_2$) is known to be a major greenhouse gas partially emitted from waste combustion facilities. According to the greenhouse gas emission inventory in Korea, the quantity of the gas emitted from waste sector in 2005 represents approximately 2.5 percent of all domestic greenhouse gas emission. Currently, the emission rate of greenhouse gas from the waste sector is relatively constant partly because of both the reduced waste disposal in landfills and the increased amounts of waste materials for recycling. However, the greenhouse gas emission rate in waste sectors is anticipated to continually increase, mainly due to increased incineration of solid waste. The objective of this study was to analyze the property of Municipal Solid Waste (MSW) and estimate $CO_2$ emissions from domestic MSW incineration facilities. The $CO_2$ emission rates obtained from the facilities were surveyed, along with other two methods, including Tier 2a based on 2006 IPCC Guideline default emission factor and Tier 3 based on facility specific value. The $CO_2$ emission rates were calculated by using $CO_2$ concentrations and gas flows measured from the stacks. Other parameters such as waste composition, dry matter content, carbon content, oxidation coefficient of waste were included for the calculation. The $CO_2$ average emission rate by the Tier 2a was 34,545 ton/y, while Tier 3 was 31,066 ton/y. Based on this study, we conclude that Tier 2a was overestimated by 11.2 percent for the $CO_2$ emission observed by Tier 3. Further study is still needed to determine accurate $CO_2$ emission rates from municipal solid waste incineration facilities and other various combustion facilities by obtaining country-specific emission factor, rather than relying on IPCC default emission factor.

우리나라 B-C유 사용 발전시설의 온실가스 배출계수 개발 (Development of Greenhouse Gas Emission Factor of B-C Oil Fired Power Plants in Korea)

  • 김진수;이시형;명수정;정재학;이성호;김기현;배위섭;전의찬
    • 환경영향평가
    • /
    • 제18권2호
    • /
    • pp.69-78
    • /
    • 2009
  • In order to provide fundamental data for developing greenhouse gas emission factor, we investigated power plants in Korea using B-C oil as Energy source. The power plant is a major source of greenhouse gases among the sectors of fossil fuel combustion, thus information of its emission factors is very essential to the establishment of control strategies for the greenhouse gas emissions. The caloric value of fuel was analyzed using calorimeter and the calorific value was 10,419 kcal/kg. The $CO_2$ concentration of flue gas and elemental analysis were conducted using GC-FID and elemental analyzer. The $CO_2$ emission factors from fuel analysis was 75,410 kg/TJ and that from $CO_2$ gas analysis was 94,265 kg/TJ. When compared with IPCC values, the emission factors by the fuel analysis was 2.5% lower, and that by $CO_2$ gas analysis was about 21.85% higher.

B-C유 화력발전소 보일러의 Non-CO2 온실가스 배출계수 개발 연구 (Development of Non-CO2 Greenhouse Gas Emission Factors for the B-C Oil Fired Boiler Power Plants)

  • 이시형;김진수;김옥헌;이정우;이성호;전의찬
    • 한국대기환경학회지
    • /
    • 제27권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The power plants are one of the GHG major source among the sectors of fossil fuel combustion, therefore information of its emission factors is very essential to the establishing control strategies for the greenhouse gas emissions. The $CH_4$ and $N_2O$ concentration from power plants were measured using GC-FID and GC-ECD. The results showed that $CH_4$ emission factor was 0.33 kg/TJ and $N_2O$ emission factor was 0.88 kg/TJ. The $CH_4$ and $N_2O$ emission factors developed in this study were compared with those for IPCC default value and other countries emission factors. The results showed that $CH_4$ emission factor was lower than IPCC default value and Finnish emission factor, but higher than Japanese emission factor. $N_2O$ emission factor was higher Japanese emission factor and IPCC default emission factor however lower than Finnish emission factor. More research is needed on our own emission factors of various energy-consuming facilities in order to stand on a higher position in international negotiations regarding the treaties on climate changes.