• Title/Summary/Keyword: gray correlation

검색결과 162건 처리시간 0.625초

방사선사진용 디지털 영상시스템의 정량적 평가에 관한 실험적 연구 (EXPERIMENTAL STUDY ON QUANTITATIVE EVALUATION OF FILM-BASED DIGITAL IMAGING SYSTEM)

  • 조형희;김은경
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.137-147
    • /
    • 1994
  • A digital imaging system using Machintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quickcapture Frame Grabber Board was evaluated for quantitative analysis of standardized periapical film with aluminum step wedge. The results were as follows: 1. Correlation between Al thickness and gray level was high-positively associated(r²=0.99, p<0.001). 2. Correlation between measured weight of experimental lesion and estimated relative lesion volume by digital subtracted radiography was also high-positively associated (r²=0.98, p<0.001). 3. As exposure time was increased, mean gray level was decreased(p<0.01) and slope of regression line between Al thickness and gray level was also decreased (p<0.01). And when the exposure time was shorter than 0.2 second, the value of r² was relatively low. On the basis of the above results, it is considered that this digital imaging system using a Macintosh Ⅱ ci computer & a high resolution CCD monochrome camera will be useful in evaluating digitized image from standardized periapical film quantitatively.

  • PDF

가축 분뇨의 오염물질 농도 추정을 위한 영상처리 시스템 (An Image Processing System to Estimate Pollutant Concentration of Animal Wastes)

  • 이대원;김현태
    • 한국축산시설환경학회지
    • /
    • 제7권3호
    • /
    • pp.177-182
    • /
    • 2001
  • 본 연구는 가축분뇨의 오염물질의 농도와 영상처리를 통해 얻어 낸 영상정보값과의 상관관계를 구하기 위해 수행하였다. CCD-카메라와 개인용 컴퓨터를 사용하여 축 분뇨의 영상을 받은 후 각 활성 영역에서의 영상정보와 공정시험 법으로 구한 오염물질과의 관계를 회귀분석법을 이용하여 다음과 같은 결론을 얻을 수 있었다. 1. 영상정보 R값은 CDD값과 결정계수가 0.9213으로 가장 높았으며, G값은 BOD값과 결정계수가 0.9019로 가장 높게 나타났으며, B값의 경우 오염물질 농도와의 상관관계는 매우 적은 것을 알 수 있었다. 2. H값은 BOD와의 결정계수($R^2$)가 0.9496으로 매우 높게 나타났다. 이는 BOD추정에 이용가능할 것으로 판단되었다. 3. BOD농도 추종을 위해서 G값,GRAY, H값, S값, 1값 등이 결정계수가 0.8이상을 나타냈으며, 그 중 H값이 가장 높은 결정계수를 나타냈으며, 이러한 정보를 이용하여 농도 추정이 가능할 것으로 판단되었다. 4. COD농도 추정을 위해서 R값, GRAY값, S값이 0.8이상의 결정계수를 나타냈으며, 그 중에서 R값과의 관계가 가장 높게 나타났으며, 이를 이용하여 간접적으로 농도 추정이 가능할 것으로 판단되었다. 5. SS농도와 영상정보값과 결정계수가 모두 0.8이하로 나타났으며, $NH_4$-N와 $NO_3$-N의 농도와 영상정보와의 결정계수는 모두 0.2이하로 매우 낮게 나타났으며, 가시광선영역의 CCD-카메라를 이용한 농도추정은 불가능할 것으로 판단되었다.

  • PDF

디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구 (A study on a development of a measurement technique for diffusion of oil spill in the ocean)

  • 이중우;김기철;강신영;도덕희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

스테레오PIV에 의한 원주후류 난류통계량 계측 (Measurement of Turbulent Properties of a Circular Cylinder with a New Stereoscopic PIV)

  • 도덕희;이원제;조용범;편용범;하승운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.471-474
    • /
    • 2002
  • A new stereoscopic PIV has been constructed using two CCD cameras, stereoscopic photogrammetry, and 3D-PTV principle. The capability of the developed stereoscopic PIV was verified through a test on the Standard Images which are provided on the website of VSJ. The arrangement of the two cameras was based on angular position For the acquisition of 3D velocity vectors, 2D velocity vectors were obtained using the gray-level cross-correlation method from the two camera images and they were matched stereoscopically. The wake of a circular cylinder was measured and turbulent properties were presented.

  • PDF

디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구 (A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean)

  • 이중우;강신영;도덕희;김기철
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Sensitivity analysis of the influencing factors of slope stability based on LS-SVM

  • Xu, Juncai;Ren, Qingwen;Shen, Zhenzhong
    • Geomechanics and Engineering
    • /
    • 제13권3호
    • /
    • pp.447-458
    • /
    • 2017
  • This study proposes a sensitivity analysis method for slope stability based on the least squares support vector machine (LS-SVM) to examine the influencing factors of slope stability. The method uses LS-SVM as an algorithm for machine learning. An appropriate training dataset is established according to the slope characteristics, and a testing dataset is designed orthogonally. Results of the testing data in the experiment design are calculated after training using the LS-SVM model. The sensitivity of the slope stability of each factor is examined via gray correlation analysis. The results are consistent with those of the traditional Bishop analysis and can be used as a reference for optimizing slope design.

실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구 (DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER)

  • 박관수;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

오스템퍼링 처리가 브레이크 드럼의 동적 특성에 미치는 영향 (Effect of Austempering Treatment on Dynamic Characteristics of Brake Drums)

  • 임경빈
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.65-70
    • /
    • 2010
  • The effect of austempering treatment on the dynamic properties of a brake drum was investigated to primarily evaluate the potential damping advantage of an AGI (austempered gray iron) drum over a PGI (pearlitic gray iron) drum. This investigation provides valuable information for brake noise reduction since the brake drum is most often the outstanding component that generates the noise of the brake assembly. Test results show that the AGI drum provided slightly larger damping values than the PGI drum for the first few major resonances observed. A finite element model of a drum was also developed to aid in studying its dynamic behavior. A good correlation was obtained between the analytical results and the actual measurement data.

디지털방사선영상에서 추출한 해면질골의 강도와 미세구조의 형태계측학적 분석에 대한 연구 (A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image)

  • 한승윤;이선복;오성욱;허민석;이삼선;최순철;박태원;김종대
    • Imaging Science in Dentistry
    • /
    • 제33권2호
    • /
    • pp.113-119
    • /
    • 2003
  • Purpose : To evaluate the relationship between morphometric analysis of bone microstructure from digital radiographic image and trabecular bone strength. Materials and Methods : One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI (100 × 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1 mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Results: Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p < 0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p < 0.05). Conclusions : The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  • PDF

색 상관 관계 기반의 색조 검출 및 핵밀도 추정을 이용한 색 항상성 알고리즘 (Color cast detection based on color by correlation and color constancy algorithm using kernel density estimation)

  • 정준우;김경환
    • 한국멀티미디어학회논문지
    • /
    • 제13권4호
    • /
    • pp.535-546
    • /
    • 2010
  • 디지털 영상은 조명 조건과 취득 카메라의 고유 특성으로 인해 의도하지 않은 색조를 가질 수 있다. 영상에 색조가 존재하면 일관된 색 정보의 인지 및 표현이 어렵기 때문에 별도의 색 보정 작업이 필요하다. 본 논문은 color by correlation을 사용한 학습 영상 선택, 후보 회색축 영역의 추출, 핵밀도 추정, 색조 제거의 4단계로 이루어진 색조 추출 및 제거 방법을 제안한다. 후보 회색축 영역 중 불명확한 회색축 영역을 핵밀도 추정을 이용하여 제거하였다. 후보 회색축 영역의 색 성분의 분포를 조사하여 색조 유무를 판단하고, 색조가 존재할 경우 색조 제거 작업을 통하여 색 항상성을 유지 시켰다. 실험을 통해 제안하는 방법이 gray world 방법, color by correlation 방법 보다 정확한 색조 추정이 가능함을 확인하였다.