• 제목/요약/키워드: grafting time

Search Result 307, Processing Time 0.024 seconds

Two-short implant supported single molar restoration in atrophic posterior maxilla : a clinical study (위축된 상악구치부에서 두 개의 짧은 임플란트 지지형 단일치관의 임상연구)

  • Song, Ho-Yong;Heo, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.628-643
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to compare marginal bone loss and survival rates of double short implants(multiple implant) which had been installed and restored in severely atrophic maxillary molar site without a grafting procedure. Material and Method: The subjects were patients (90 patients, 180 implants) who had been installed double short implants in severely atrophic maxillary single molar site without bone augmentation procedure from 2006 to 2014 in dental clinic in Chuncheon city. Following data were collected from dental records and radiographic panoramic views: patient's age, gender, smoking status, implant site, timing of implant installation, residual ridge height. The correlation between those factors and survival rate and marginal bone loss were analyzed. Statistical analysis was performed using Chi-square test, Student's t- test and ANOVA. Result: Eleven implants in 6 patients failed and the cumulative survival rate was 93.9%. No significant differences were found in relation to the following factors: patient's age, gender, implant site, timing of implant installation (P> .05). There were significant differences in smoking status and residual ridge height(P< .05). The average follow-up time was $45{\pm}14.7months$. The mean marginal bone loss of survived 169 implants was $0.08{\pm}0.59mm$. Conclusion: Despite the short term outcomes, the survival rate of double short implants was comparable to normal length implants. This study demonstrated that placement of double short implants without the use of bone grafting procedure for severely atrophic posterior maxilla is a simple and predictable treatment procedure.

Synthesis of SAPP-g-(AN/St) Fibrous Ion-Exchanger by E-beam Pre-irradiation and Their Adsorption Properties for Uranium Ion (E-beam 전조사법에 의한 SAPP-g-(AN/St) 섬유상 이온교환체의 합성 및 우라늄 흡착특성)

  • Hwang, Taek-Sung;Park, Jin-Won;Kim, Kwang-Young
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.49-55
    • /
    • 2001
  • The bi-functional ion exchangers, SAPP-g-(AN/St) were synthesized with mixed vinyl monomers(acrylonitrile and styrene) onto PP fabric by the pre-irradiation grafting with E-beam and its subsequent amidoximination and sulfonation. The degree of grafting of PP-g-(AN/St) was increased with decreasing acrylonitrile composition in the mixed monomers. The water uptake of copolymers increased with decreasing in the amidoxime ratio in the copolymers and increased by sulfonation, but decreased by amidoximation. The $UO_2^{2+}$ adsorption capacity of SPP-g-St, APP-g-AN, and SAPP-g-(AN/St) were 12.4, 34.0, and 38.0 mg/g, respectively and the optimum adsorption time is about 50 hrs. As a result of uranium adsorption, the synthesized ion exchanger, which we obtained have also good affinity toward the adsorption or chelating with $UO_2^{2+}$ ions.

  • PDF

A Modified McIndoe Operation for Treatment of Vaginal Agenesis (개량된 McIndoe 술식을 이용한 무질증 환자의 질 재건)

  • Tark, Kwan Chul;Choi, Bong Kyoon;Choi, Jong Woo
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.117-123
    • /
    • 2005
  • The reconstructive modalities for vaginal reconstruction include simple dilatation, skin graft, use of intestinal segments and various methods using flaps. However, skin grafting procedure is the most commonly used technique and the McIndoe procedure is a representative technique among skin grafting procedures. McIndoe procedure is easier, faster and has a lower morbidity compared to other techniques. However the conventional McIndoe procedure has several problems such as incomplete vestibule formation, excessive bleeding during dissection, possibility of recto-vaginal or urethro-vaginal fistula formation, late vaginal contracture and discomfort in wearing hard plastic mold for a long time after operation. To solve these problems, the authors modified the conventional McIndoe procedure in several perspectives. The undeveloped vestibule was incised with X-shaped mucosal incision between the urethral opening and posterior margin of the vestibule and deepened by blunt finger dissection to provide a sufficient diameter & length of the neovagina and to minimize bleeding. A sizable medium thickness split skin graft was harvested and wrapped over a roll gauze-filled condom mold. Applying multiple stab incision on the skin grafted condom mold, it was inserted into the prepared neovaginal canal. Distal margin of the skin graft was secured with tips of the mucosal flaps created by X-shaped vestibular incision to prevent accidental extrusion of the skin grafted mold. During last 15 years, we applied this modification to 20 vaginal agenesis patients and investigated results of the 12 patients who could be followed up serially including hematoma formation and skin graft survival rate, size, depth, presence of late contracture, appearance, comfortness, and hygiene of the neovagina. And they were compared with 8 patients of 20 patients who underwent conventional McIndoe procedures. The modified McIndoe procedure revealed lower complication rate, higher patient satisfaction and better functional results.

Clavicle Nonunion: Matchstick Bone-grafting and Osteosynthesis

  • Park, Yong Bok;Yoo, Jae Chul;Park, Geun Min;Kum, Dong Ho;Tauheed, Mohammed;Jeong, Jeung Yeol
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Background: This study was conducted to evaluate the surgical outcomes of plate fixation using autologous iliac bone graft shaped in the form of a matchstick in clavicle nonunion resulting from prior surgical or non-surgical management. Methods: From May 2005 to February 2013, 17 patients underwent surgery for clavicle nonunion. The mean age at the time of surgery was 48.8 years. The iliac bone was harvested and shaped into slivers approximately 3 cm long, which resembled matchsticks. After opening of the medullary canal, the plate and screws were applied and cancellous bone was placed at the nonunion site. Matchstick bone grafts which were longitudinally placed and encircled on the nonunion site were tied with periosteum using 3-4 stitches. Union was determined via postoperative plane X-ray. Clinical status was evaluated using the visual analogue scale score for pain, and Constant and American Shoulder Elbow Surgeon score. Results: All patients had a stable radiological union at the follow-up. The mean duration from index operation to nonunion operation was 13.2 months (7-32 months). The mean follow-up period was 20.1 months (8-56 months), and the mean duration until union was 11.2 weeks (8-16 weeks). All clinical scores were improved at the final follow-up (p<0.001). The mean segmental defect was $3.3{\pm}2.6mm$ (1-18 mm); and the difference in clavicular length between operative and non-operative site was $5.9{\pm}6.9mm$. Conclusions: Matchstick shaped autologous iliac bone grafting technique in clavicle nonunion is acceptable with a high union rate.

Grafting and Characterization of Zwitter Ionic Poly(ethylene glycol) on Gold-Coated Nitinol Surface Chemisorbed with L-Cysteine (시스틴으로 화학흡착된 금 코팅 니티놀 표면에 앙쪽성 이온 폴리에틸렌글리콜의 그래프트 및 특성 평가)

  • Shin, Hong-Sub;Park, Kwi-Deok;Kim, Jae-Jin;Kim, Ji-Heung;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.84-90
    • /
    • 2009
  • Nitinol alloy (TiNi) has been widely used in vascular stents. To improve the blood compatibility of Nitinol alloy, its surface was chemically modified in this study. Nitinol was first coated with gold, then chemisorbed with L-cysteine (C/N), and followed by grafting of zwitter ionic poly(ethylene glycol) (PEG) (PEG-$N^+-SO_3{^-}$) to produce TiNi-C/N-PEG-N-S. The zwitter ionic PEG grafted on the Nitinol surface was identified by ATR-FTIR, ESCA and SEM. The hydrophilized surface was proven by the decrease of water contact angle. In addition, from the blood compatibility tests such as protein adsorption, platelet adhesion, and blood coagulation time, the surface-modified TiNi alloy exhibited a better blood compatibility as compared to the untreated Nitinol control. These results indicated a feasibility of synergistic effect of hydrophilic PEG and antithrombotic zwitter ion.

Outcomes of Coronary Artery Bypass Grafting after Extracorporeal Life Support in Patients with Cardiac Arrest or Cardiogenic Shock

  • Kim, Younghwan;Cho, Yang-Hyun;Yang, Ji-Hyuk;Sung, Kiick;Lee, Young Tak;Kim, Wook Sung;Lee, Heemoon;Cho, Su Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.70-77
    • /
    • 2019
  • Background: Extracorporeal life support (ECLS) is used as a bridge to revascularization in high-risk patients with ischemic heart disease. We reviewed our experiences of coronary artery bypass grafting (CABG) after ECLS in patients with cardiac arrest or refractory cardiogenic shock. Methods: We retrospectively reviewed 4,616 patients who underwent CABG at our institution between May 2006 and February 2017. We identified patients who underwent CABG following ECLS for cardiogenic shock or cardiac arrest. Twenty-three patients (0.5% of all CABG cases) were enrolled in the analysis. Their median age was 65 years (Q1-Q3, 58-77 years). Nine patients (39.1%) were diagnosed with ST-elevation myocardial infarction. Mechanical complications after acute myocardial infarction, including acute mitral regurgitation, left ventricular rupture, and ventricular septal defect, occurred in 9 patients (39.1%). Results: The median time from cardiopulmonary resuscitation to ECLS initiation was 25 minutes (Q1-Q3, 18.5-28.5 minutes). Conventional CABG was performed in 10 patients (43.5%) who underwent concomitant intracardiac procedures. Postoperative ECLS was required in 16 patients (69.5%). The rate of successful ECLS weaning was 91.3% (n=21). There were 6 early mortalities (26.1%). Conclusion: CABG after ECLS was very rare in real-world circumstances. Although the early mortality rate was high, the risk of mortality may be acceptable under such devastating circumstances.

On the Research of 17th Century Joseon Dynasty's Bulsang, a Buddist Statue, Manufacturing Technique by Examining the Daeungbojeon Hall Samse-bulsang, The Buddha of the Three Words, at the Haenam Daeheungsa Temple (해남 대흥사 대웅보전 삼세불상을 통해 본 17세기 조선시대 불상의 제작기법 연구)

  • Lee, Su-yea
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.1
    • /
    • pp.164-179
    • /
    • 2014
  • The Buddhas of the Three Words in a form of arranging Bhaiṣajyaguru and $Amit{\bar{a}}bha$ at its side based on ${\acute{S}}{\bar{a}}kyamuni$ at the center is enshrined in Daeungbojeon Hall of Daeheungsa Temple located at Haenam. So far, this Buddhas of the Three Words has been known as a wooden Buddha statue. However, as a result of X-ray screening, in left/right Buddha statues excepting main Buddha, wood and molding clay layer were observed at the same time. Therefore, this study intended to observe its internal structure, grafting method and to clarify making technique of Buddha statue during Joseon era based on image information being obtained through X-ray screening of The Buddhas of the Three Words of Daeheungsa Temple. As its result, it was revealed that form of ${\acute{S}}{\bar{a}}kyamuni$ was completed by mainly grafting 5 pieces of timber and this statue shows a typical wood grafted Buddha statue during Joseon era. Form of Bhaiṣajyaguru and $Amit{\bar{a}}bha$ were completed based on molding technique by applying clay on sculpture similar to its appearance after sculpturing more than 10 pieces of timber through its grafting. In other words, internal timber is considered to play a role of its core and grafting method of timber is more close to a technique of molding Buddha statue than to that of wooden Buddha statue during Joseon era. However, clay was directly applied on timber thinly, not applying clay thickly on it after winding straw rope on wooden core and its characteristic is that its facial area was completely composed of wooden construction only. Therefore, it is hard to rule out a possibility that the original sculpturing intention of an artist might be a wooden Buddha statue but in view of the fact that a word, 'molding' was used in a record of relics buried in statue, it could be seen that this Buddha statue might have been recognized as a molding statue at the time when creation of this statue was completed. It is considered that number of case of making statue based on this technique would be more increased when more results of X-ray screening should be accumulated and if more data should be collected, it would provide a significant evidence for identifying chronological, regional aspects of making technique of Buddha statue.

Surface Modification of Polypropylene Fiber by Plasma Discharge (방전처리에 의한 Polypropylene섬유의 표면개질)

  • 허만우;이창재;강인규;한명호;김삼수;임학상
    • Textile Coloration and Finishing
    • /
    • v.11 no.2
    • /
    • pp.27-37
    • /
    • 1999
  • Polypropylene(PP) films were treated with plasma glow discharge to produce peroxy radicals on the surfaces. The peroxy radicals formed on the PP film surfaces were subsequently used for the graft polymerization of acrylic acid and acrylamide in an aqueous solution by heating, respectively. Introduction of acrylic acid and acrylamide on the PP film could be confirmed by the observation of carbonyl and primary amine absorptions based on carboxylic acid and amide, respectively. And introduction of functional group could be confirmed by weight analysis and ESCA. The water contact angle(90$^{\circ}$) of PP film was constant, irrespective of elapsed time, while plasma-treated and functional monomer-grafted PP films were slowly increased with elapsed time, showing the rearrangement of surface polar groups in air condition. The water contact angle$(90^\circ)$ of PP film was decreased by the plasma treatment$(56^\circ)$ and further decreased by the grafting of acrylic acid$(34^\circ)$ and acrylamide$(37^\circ)$, indicating increased hydrophilicity of the modified surfaces. The water contact angle of plasma-treated PP film increased a little as time elapsing. The half-life periods of surface voltage on acrylic acid-(31sec) and acrylamide-grafted PP(42sec) were significantly decreased when compared to those on PP(950sec) and plasma-treated PP film(241sec). In the experiments using acid, basic and disperse dyes, absorbance and $\Delta{E}$ values of functional monomer-grafted PP films were significantly increased than that of oxygen plasma-treated one.

  • PDF

Comparative analysis of the in vivo kinetic properties of various bone substitutes filled into a peri-implant canine defect model

  • Jingyang Kang;Masaki Shibasaki;Masahiko Terauchi;Narumi Oshibe;Katsuya Hyodo;Eriko Marukawa
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.96-107
    • /
    • 2024
  • Purpose: Deproteinized bovine bone or synthetic hydroxyapatite are 2 prevalent bone grafting materials used in the clinical treatment of peri-implant bone defects. However, the differences in bone formation among these materials remain unclear. This study evaluated osteogenesis kinetics in peri-implant defects using 2 types of deproteinized bovine bone (Bio-Oss® and Bio-Oss/Collagen®) and 2 types of synthetic hydroxyapatite (Apaceram-AX® and Refit®). We considered factors including newly generated bone volume; bone, osteoid, and material occupancy; and bone-to-implant contact. Methods: A beagle model with a mandibular defect was created by extracting the bilateral mandibular third and fourth premolars. Simultaneously, an implant was inserted into the defect, and the space between the implant and the surrounding bone walls was filled with Bio-Oss, Bio-Oss/Collagen, Apaceram-AX, Refit, or autologous bone. Micro-computed tomography and histological analyses were conducted at 3 and 6 months postoperatively (Refit and autologous bone were not included at the 6-month time point due to their rapid absorption). Results: All materials demonstrated excellent biocompatibility and osteoconductivity. At 3 months, Bio-Oss and Apaceram-AX exhibited significantly greater volumes of formation than the other materials, with Bio-Oss having a marginally higher amount. However, this outcome was reversed at 6 months, with no significant difference between the 2 materials at either time point. Apaceram-AX displayed notably slower bioresorption and the largest quantity of residual material at both time points. In contrast, Refit had significantly greater bioresorption, with complete resorption and rapid maturation involving cortical bone formation at the crest at 3 months, Refit demonstrated the highest mineralized tissue and osteoid occupancy after 3 months, albeit without statistical significance. Conclusions: Overall, the materials demonstrated varying post-implantation behaviors in vivo. Thus, in a clinical setting, both the properties of these materials and the specific conditions of the defects needing reinforcement should be considered to identify the most suitable material.

Minimally Invasive Coronary Artery Bypass Grafting (소침습적 관상동맥우회술)

  • Na, Chan-Young;Lee, Young-Tak;Park. Joong-Won;Chung, Do-Hyun;Jung, Ill-Sang;Jung, Yoon-Seup;Kim, Ok-Sung;Bang, Jung-Hyun;Lee, Sub;Chung, Chul-Hyun;KIM, Woong-Han;Park, Young-Kwan;Kim, Chong-Whan;Hong, Sung-Nok;Han, Jae-Jin;Lee, Gun
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.118-124
    • /
    • 1998
  • Minimally invasive coronary artery bypass grafting without using cardiopulmonary bypass (CPB) is a recently accepted modality of myocardial revascularization prcedures which is particularly suitable to the patients with lesions in the left anterior descending(LAD) and the right coronary arteries. Of the consecutive 35 patients of coronary artery bypass grafting performed at Sejong General Hospital from March to August 1996, six patients underwent minimally invasive coronary artery bypass grafting without CPB. All had stenotic lesions of the LAD more than 90%. Bypass grafting of the LAD was approached through midline sternotomy in one, through ministernotomy in two, and through limited left anterior thoracotomy in three patients, respectively. The internal mammary arteries were prepared without the use of thoracoscope. The mobilized mammary arteries were connected directly to the LAD in 5 patients, and the anastomosis required interposition of a segment of the radial artery in the remaining one. The diagonal branch was revascularized with the saphenous vein graft at the same time in one patient. No blood transfusion was necessary in 2 patients, and average blood required during surgery was 800ml in 4 patients. All patients were extubated from 4 to 14 hours(mean 9 hours) after operation. Early postoperative coronary angiography in 5 patients between 7 and 10 days after surgery has proved full patency of the grafts. With these limited clinical experiences, the clinical results demonstrated that minimally invasive coronary artery bypass grafting without CPB is an useful procedure especially in patients with isolated lesion in the proximal LAD.

  • PDF