• 제목/요약/키워드: graft ratio

검색결과 224건 처리시간 0.023초

Redox계에 의한 MAA Gragt 속도에 관한 연구 (The Study on the Gragting Rate MAA onto Silk Fiber by Redox System)

  • 배도규;김종호
    • 한국잠사곤충학회지
    • /
    • 제39권1호
    • /
    • pp.62-66
    • /
    • 1997
  • The MAA graftings in silk fiber were done by redox system for the purpose of investingating the effect of ferrous sulfate additive on the grafting rate and graft ratio in various conditions. The graft ratio was higher in redox graft system than in peroxide graft system and the graft ratio in redox graft system was also higher depending on decrease of ferrous sulfate additive. The saturation graft ratio obtained by empirical equation, log X=K/t, was increasing depending on the increase of ferrous sulfate additive. Initial grafting rate was increased but the latter grafting rate was decreased in redox graft system. The effects of liquor ratio(L.R.) on the graft ratio in redox graft system, were higher in high L.R. than in low L.R..

  • PDF

나일론 6 직물의 아크릴산 그라프트 중합과 그라프트 나일론의 세척성 -그라프트 나일론 직물의 헤모글라빈 오구 세척성 향상- (The Effect of Graft using Acrylic Acid on the Detergency for the Nylon 6 Fabric -Improvement of Hemoglobin Removing Rate on Grafted Nylon-)

  • 오수민;김인영;송화순
    • 한국의류학회지
    • /
    • 제23권7호
    • /
    • pp.1064-1072
    • /
    • 1999
  • Nylon fabric was grafted for the purpose of the development of detergency against the hemoglobin as a protein soil. By free-radical producing chemical initiator systems the graft using acrylic acid(AA) as a hydrophilic vinyl monomer was performed to change surface energies in the presence of ammonium persulfate(APS) as an initiator and then acrylic acid grafted Nylon was treated with NaOH solution. The surface morphology for Nylon-g-NaAA with changing graft rate were studied by scanning electron microscopy (SEM) The properties of the Nylon such as diameter tenacity elongation contact angle and the hemoglobin removal were also investigated. The diameter of grafted Nylon fiber increased as the graft ratio increased. The tenacity of grafted Nylon also increased with increasing graft ratio up to 15% The elongation however decreased gradually according to graft, The contact angle decreased after graft and alkaline treatment. The amount of hemoglobin on the grafted Nylon increased in proportion to the graft ratio. Hemoglobin was easily removed from grafted Nylon while it was difficult to be removed from ungrafted Nylon. The detergency of hemoglobin for grafted Nylon decreased when the graft ratio exceeded 15% The removal of hemoglobin increased markedly with increasing hemoglobin content and revolution speed. Therefore the removal of hemoglobin was improved due to graft and alkaline treatment.

  • PDF

Styrene-Butadiene 고무의 아크릴아미드 UV 광그라프팅 반응 (Ultraviolet Photografting Reaction of Acrylamide onto Styrene-Butadiene Rubber)

  • 이권익;류승훈
    • Elastomers and Composites
    • /
    • 제33권5호
    • /
    • pp.363-369
    • /
    • 1998
  • UV를 이용하여 반응성 모노머인 아크릴아미드를 SBR에 광그라프트 시키는데 있어서 주요한 인자인 모노머 농도, 조사시간 그리고 카본블랙의 함량이 모노머의 그라프트율에 미치는 영향을 살펴보았다. 광개시제로는 benzophenone을 사용하였다. 아크릴아미드의 그라프트율을 측정하기 위하여 FT-IR ATR과 증류수를 이용하여 정접촉각을 측정하였다. 아크릴아미드의 함량과 UV 조사시간이 증가함에 따라 그라프트율은 증가하였으며 또한 접촉각은 감소하는 현상을 나타내었다. SBR중 카본블랙 함량이 증가함에 따라 그라프트율이 증가함을 알 수 있었다.

  • PDF

Technetium-99m 골주사를 이용한 하악골의 자가골 및 동종골 이식의 평가에 대한 실험적 연구 (TECHNETIUM-99m BONE SCAN FOR EVALUATING AUTOLOGOUS ILIAC BONE GRAFT AND FREEZE-DRIED BONE ALLOGRAFT IN DOG'S MANDIBLE)

  • 진성박;김수경
    • 대한치과의사협회지
    • /
    • 제22권1호통권176호
    • /
    • pp.37-48
    • /
    • 1984
  • Clinical assessment of bone-graft healing in the maxillofacial region is generally limited to clinical evaluation, radiographs, and biopsy. Sequential interpretation of osseous repair, more sensitive than with conventional radiography is possible with a non-invasive, non-destructive radionuclide method. Technetium-99m radionuclide bone scan was used in the evaluation of the progress of osteogenic activity in autologous iliac bone graft and freeze-dried bone allograft of dog's mandible. Bone scan was performed at 1wk, 2wk, 4wk, 6wk, and 8wk after grafting. In autologous graft the activity ratio for the graft bone remained greater than that of the host since 2자 after grafting; however, in lyophilized allograft the activity ratio for graft bone was greater than that of the host at 6자 after grafting.

  • PDF

아크릴산 그라프트 중합한 나일론 직물의 헤모글로빈 오구 세척성 -그라프트 나일론 직물에 대한 헤모글로빈 부착상태와 세척성- (Removal of Hemoglobin from Acrylic Acid Grafted Nylon Fabric The Removal and the State of Adhesion of Hemoglobin on Grafted Nylon Fabric-)

  • 오수민;김인영;송화순
    • 한국염색가공학회지
    • /
    • 제11권3호
    • /
    • pp.41-48
    • /
    • 1999
  • The removal of hemoglobin from acrylic acid grafted Nylon fabrics has been investigated. In order to change detergency of Nylon 6 fabric, acrylic acid(AA) were graft copolymerized on Nylon fabric using ammonium persulfate(APS) as a initiator, and then acrylic acid grafted Nylon was treated with NaOH solution. The graft ratio increased linearly with increasing acrylic acid concentration. The graft ratio was the highest when the concentration of APS was 0.05%, and it decreased as the concentration of APS increased. The surface of Nylon fabric became rough due to graft. Moisture regain was increased by graft and alkaline treatment, contact angle was also improved compared with the ungrafted. The hemoglobin was easily solubilized and removed from grafted Nylon fabric, while it was difficult to remove hemoglobin from ungrafted Nylon fabric. The effects of graft on removal of hemoglobin was related with increase of moisture regain and transformation of COOH to COONa by alkaline treatment.

  • PDF

Preparation of Alginate/Poly(N-isopropylacrylamide) Hydrogels Using Gamma-ray Irradiation Grafting

  • Lee, Young-Moo;Lee, Sang-Bong;Seo, Sung-Mi;Lim, Youn-Mook;Cho, Seong-Kwan;Nho, Young-Chang
    • Macromolecular Research
    • /
    • 제12권3호
    • /
    • pp.269-275
    • /
    • 2004
  • To graft N-isopropylacrylamide (NIPAAm) onto alginate, varying dosages of ${\gamma}$-rays were irradiated onto alginate films in deionized water and methanol media, which are non-solvents of alginate. We investigated the hydrogels graft ratio, mechanical strength, swelling kinetics and ratio, and behavior with respect to drug release. The graft yield of NIPAAm increased upon increasing the irradiation dose. The use of the aqueous solution increased the graft yield relative to that obtained in methanol. The mechanical strength of the grafted hydrogels increased after grafting with NIPAAm. In a study of the swelling kinetics, we found that all hydrogels reached an equilibrium swollen state within 3 h. The equilibrium swelling ratio of the hydrogels decreased upon increasing the irradiation dose. The swelling ratio of the hydrogels decreased dramatically between 30 and 35$^{\circ}C$ because phase separation of NIPAAm occurred at 32$^{\circ}C$. The swelling process, with respect to the temperature change, was repeatable. An NIPAAm-grafted alginate containing a drug sustained its release rate until 3 h after an initial high drug release caused by a burst effect.

EPDM에 방향족 카르복시산을 함유하는 아크릴 단량체의 그라프트 공중합과 기계적 특성 (Graft Copolymerization of Acrylic Monomer Containing Aromatic Carboxylic Acid Group onto EPDM and Their Mechanical Properties)

  • 박현주;박종혁;배종우;김구니;오상택
    • Elastomers and Composites
    • /
    • 제47권3호
    • /
    • pp.216-222
    • /
    • 2012
  • 본 연구에서는 p-hydroxybenzoic acid(HBA)와 acryloyl chloride(AC)의 반응에 의해 방향족 카르복실기를 가지는 아크릴 단량체 p-acryloyloxybenzoic acid(ABA)를 합성하였으며, 합성된 ABA 단량체와 benzoyl peroxide(BPO) 개시제를 이용하여 톨루엔 용매 하에서 에틸렌-프로필렌-디엔 고무(EPDM)에 그라프트 공중합 시켰다. 합성된 단량체 ABA와 그라프트 공중합체 EPDM-g-ABA의 구조는 FT-IR, $^1H$-NMR 및 $^{13}C$-NMR 분광기로 분석하였으며, 개시제 함량과 단량체의 농도가 증가할수록 그라프트율이 높아지는 것을 확인하였다. 그라프트율이 증가할수록 인장강도와 영구압축줄음율과 같은 기계적 특성은 향상되었다. 또한 유리전이온도($T_g$와 초기 열분해 온도는 약간씩 상승하였다.

MA 그라프트 폴리에스테르직물의 물성 및 태변화에 관한 연구 (A Study on the Physical Properties and Handle of Polyester Fabrics Grafted with Methacrylic Acid)

  • 백천의;조승식;송화순
    • 한국의류학회지
    • /
    • 제20권1호
    • /
    • pp.19-27
    • /
    • 1996
  • The purpose of this study is the investigation of the physical properties, handle variation of polyester fabrics grafted methacrylic acid. The results are as follow 1. In the case of moisture recovery, MA-g-PET results in an improvement of approximately 4% when the graft ratio reaches 25%, whilst Na-MA-g-PET results in an improvement of approximately 9% when the graft ratio reaches 20%. 2. The static electricity of Na-MA-g-PET, is rarely generated when the graft ratio exceeds 10% . 3. The T.H.V. indicate that the values had deteriorated in the case of MA-g-PET, whilst the N a-Ma-a.PET values demonstrated superiority. 4. The value resulting from the MA-g-PET and Na-MA-g-PET treatment methods are calculated as being 0.0130, whilst the value pursuant to graft ratio is 0.0000.

  • PDF

Amphiphilic graft copolymers: Effect of graft chain length and content on colloid gel

  • Nitta, Kyohei;Kimoto, Atsushi;Watanabe, Junji;Ikeda, Yoshiyuki
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권2호
    • /
    • pp.97-109
    • /
    • 2015
  • A series of amphiphilic graft copolymers were synthesized by varying the number of graft chains and graft chain lengths. The polarity of the hydrophobic graft chain on the copolymers was varied their solution properties. The glass transition temperature of the copolymers was in the low-temperature region, because of the amorphous nature of poly (trimethylene carbonate) (PTMC). The surface morphology of the lyophilized colloid gel had a bundle structure, which was derived from the combination of poly(N-hydroxyethylacrylamide)( poly(HEAA)) and PTMC. The solution properties were evaluated using dynamic light scattering and fluorescence measurements. The particle size of the graft copolymers was about 30-300 nm. The graft copolymers with a higher number of repeating units attributed to the TMC (trimethylene carbonate) component and with a lower macromonomer ratio showed high thermal stability. The critical association concentration was estimated to be between $2.2{\times}10^{-3}$ and $8.9{\times}10^{-2}mg/mL$, using the pyrene-based fluorescence probe technique. These results showed that the hydrophobic chain of the graft copolymer having a long PTMC segment had a low polarity, dependent on the number of repeating units of TMC and the macromonomer composition ratio. These results demonstrated that a higher number of repeating units of TMC, with a lower macromonomer composition, was preferable for molecular encapsulation.

폴리올레핀의 반응 조건별 산변성도 변화 및 Al-CPP 라미네이션 박리강도 변화 (Changes in Acid Graft Ratio and Al-CPP Lamination Peel Strength by Polyolefin Reaction Conditions)

  • 박종현;채홍준
    • 접착 및 계면
    • /
    • 제25권1호
    • /
    • pp.152-156
    • /
    • 2024
  • 에폭시 접착소재의 단점인 경질화에 따른 성형성 부족을 개선하고자 무수말레인산을 이용한 산변성 폴리올레핀 기반 2액형 에폭시 접착소재를 연구하였다. 반응 조건에 따른 산변성도를 파악하기 위하여 공정별, 폴리올레핀 분자량/개시제 반감기/개시제 함량별 연구를 진행하였으며, 제조된 산변성 폴리올레핀을 에폭시 경화제와의 혼합 후 알루미늄과 CPP 필름 라미네이션 접착소재로 사용하였다. 용융공정 대비 용액공정의 산변성 효율이 약 30% 우수하였으며, 산변성율이 증가할수록 박리강도는 증가함을 확인하였다.