• Title/Summary/Keyword: gradient correlation

Search Result 370, Processing Time 0.027 seconds

Perturbation/Correlation based Optimization (섭동/상관관계 기반 최적화 기법)

  • Lee, Soo-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.875-881
    • /
    • 2011
  • This paper describes a new method of estimating the gradient of a function with perturbation and correlation. We impose a known periodic perturbation to the input variable and observe the output of the function in order to obtain much richer and more reliable information. By taking the correlation between the input perturbation and the resultant function outputs, we can determine the gradient of the function. The computation of the correlation does not require derivatives; therefore the gradient can be estimated reliably. Robust estimation of the gradient using perturbation/correlation, which is very effective when an analytical solution is not available, is described. To verify the effectiveness of perturbation/correlation based estimation, the results of gradient estimation are compared with the analytical solutions of an example function. The effects of amplitude of the perturbation and number of samplings in a period are investigated. A minimization of a function with the gradient estimation method is performed.

Correlation Between Shoulder Gradient, Range of Motion of the Neck, and Subjective Pain level of the Potential Risk Group of Smart-phone Addiction (스마트폰 중독 잠재위험군의 어깨 기울기, 목 관절가동범위 및 주관적 통증 정도의 상관관계)

  • Jeong, Yeonwoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose : The purpose of this study was to investigate the correlation between shoulder gradient, range of motion of the neck, and subjective pain level of the potential risk group of smart-phone addiction. Methods : The subjects of this study were 90 women's who had potential risk of smart-phone addiction. VAS was used to measure subjectively pain intensity. Global Postural System was used to measure forward head posture. CROM was used to measure flexion, extension, lateral flexion of cervical range of motion. Results : The results of this study showed that was significant positive correlation between the both shoulder gradient, and cervical range of motion(p<.05). Statistically significant negative correlation between the VAS and left lateral flexion(p<.05). Conclusions : The difference between the gradient of both shoulders increased with the use of smart-phone addiction, and the cervical left lateral flexion decreased as the pain increased. This suggests that recognition on decrease of using smart phone and postural correction is necessary.

Sub-pixel Evaluation with Frequency Response Analysis

  • OKAMOTO Koji
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.14-22
    • /
    • 2001
  • The frequency responses on the sub-pixel evaluation technique were investigated using the Monte-calro Simulation technique. The frequency response by the FFT based cross-correlation gives very good results, however, the gain loss does exist for the small displacement, (less than 0.5 pixel). While, the no gain loss is observed in the Direct Cross-correlation, however, the sub-pixel accuracy was limited to be about 0.1 pixel, i.e., it could not detect the small displacement. To detect the higher accurate sub-pixel displacement, the gradient based technique is the best. For the small interrogation area (e.g., 4x4), only the gradient technique can detect the small displacement correctly.

  • PDF

Biologically Inspired Sensing Strategy using Spatial Gradients

  • Lee, Sooyong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.141-148
    • /
    • 2020
  • To find food, homes, and mates, some animals have adapted special sensing capabilities. Rather than using a passive method, they discharge a signal and then extract the necessary information from the response. More importantly, they use the slope of the detected signal to find the destination of an object. In this paper, similar strategy is mathematically formulated. A perturbation and correlation-based gradient estimation method is developed and used as a sensing strategy. This method allows us to adaptively sense an object in a given environment effectively. The proposed strategy is based on the use of gradient values; rather than instantaneous measurements. Considering the gradient value, the sampling frequency is planned adaptively, i.e., sparse sampling is performed in slowly varying regions, while dense sampling is conducted in rapidly changing regions. Using a temperature sensor, the proposed strategy is verified and its effectiveness is demonstrated.

Gradient based Stereo Temperature Sensor System (구배값을 이용한 스테레오 열감지 센서 시스템)

  • Lee, Sooyong
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.258-263
    • /
    • 2019
  • Some animals have special sensing functions in order to find foods, home and mates. Instead of passively sensing, they discharge signals and then extract necessary information from the response. More importantly, they utilize the gradients of the sensed signal in order to find the destination or objects. In this paper this special strategy is formulated mathematically, i.e., the perturbation and the correlation based gradient estimation is developed. A stereo sensor system using temperature sensors mounted on motors is developed for verification. The proposed method can estimate the gradient of the measured value accurately. Using this method, the direction in the maximum measured value can be estimated accurately, and the position of the heat source can be estimated from the intersection of the directions estimated from both sensors.

Assessment of Gradient-based Digital Speckle Correlation Measurement Errors

  • Jian, Zhao;Dong, Zhao;Zhe, Zhang
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.372-380
    • /
    • 2012
  • The optical method Digital Speckle Correlation Measurement (DSCM) has been extensively applied due its capability to measure the entire displacement field over a body surface. A formula of displacement measurement errors by the gradient-based DSCM method was derived. The errors were found to explicitly relate to the image grayscale errors consisting of sub-pixel interpolation algorithm errors, image noise, and subset deformation mismatch at each point of the subset. A power-law dependence of the standard deviation of displacement measurement errors on the subset size was established when the subset deformation was rigid body translation and random image noise was dominant and it was confirmed by both the numerical and experimental results. In a gradient-based algorithm the basic assumption is rigid body translation of the interrogated subsets, however, this is in contradiction to the real circumstances where strains exist. Numerical and experimental results also indicated that, subset shape function mismatch was dominant when the order of the assumed subset shape function was lower than that of the actual subset deformation field and the power-law dependence clearly broke down. The power-law relationship further leads to a simple criterion for choosing a suitable subset size, image quality, sub-pixel algorithm, and subset shape function for DSCM.

2D Correlation Analysis of Spin-Coated Films of Biodegradable P(HB-co-HHx)/PEG Blends

  • Kim, Min-Kyung;Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.4005-4010
    • /
    • 2011
  • We investigated thermal behavior of spin-coated films of P(HB-co-HHx)/PEG blends by using infraredreflection absorption (IRRAS) spectroscopy and 2D correlation spectroscopy. Based on 2D IRRAS correlation spectra, we could determine the sequence of spectral intensity changes with increasing temperature that PEG band changes first and then a band for crystalline component of P(HB-co-HHx) changes before a band for amorphous component. The intensities of bands for PEG and amorphous P(HB-co-HHx) were changed greatly as PEG weigh % of P(HB-co-HHx)/PEG blends increased. Transition temperatures of P(HB-co-HHx)/PEG blends were successfully determined by 2D gradient mapping method. The transition temperature of spincoated films of 98/2 and 90/10 P(HB-co-HHx)/PEG blends and 80/20 P(HB-co-HHx)/PEG blend determined by 2D gradient map are, respectively, about 137.5 and $132.5^{\circ}C$. Furthermore, P(HB-co-HHx)/PEG blends show an additional transition temperature that have been interpreted in terms of different lamellar thicknesses in spin coated films.

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

Numerical Study of Radial Temperature Gradient Effect on Taylor Vortices (반경방향으로의 온도구배가 Taylor Vortex에 미치는 영향에 대한 수치적 연구)

  • Kang, Chang-Woo;Yang, Kyung-Soo;Yoon, Dong-Hyeog
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.900-908
    • /
    • 2009
  • Numerical simulation has been carried out to investigate the influence of radial temperature gradient on the Taylor Vortex flow. Varying the Grashof number, we study the detailed flow and temperature fields. The current numerical results show good agreement with the experimental results currently available. It turns out that wavy spiral vortices are generated by increasing temperature gradient. We classify flow patterns for various Grashof numbers based on the characteristics of flow fields and spiral vortices. The correlation between Grashof number with wave number shows that the spiral angle and size of Taylor vortices increase with increasing temperature gradient. Temperature gradient does not have a great influence on the heat transfer rate of the cylinder surfaces.

Experimental Study on the Characteristics of Water Flow Through Sand Layer (모래층에서의 수류의 특성에 관한 실험적 연구)

  • 남궁달;김철기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3833-3839
    • /
    • 1975
  • The object of this experiment is to find out some flow characteristics of water through sand layer, to prevent moving sands in the filters of the fill Dam, infiltration gallery, well and Deversion Weir. This experiment was accomplished with different particle Sizes of Six Samples and different hydraulic gradient. The results obtained are Summarized as follows. 1. The critical hydraulic gradients for laminar flow was found to be between 1 and 2 when the sand used had the effective diameter, D10 of between 0.18cm and 0.45cm. 2. The critical hydraulic gradients for different particle sizes of sands were varied considerably. 3. There was a negative correlation between critical hydraulic gradient and critical Velocity, and between effective particle diameter D10 and critical hydraulic gradient respectively. 4. In spite of relatively small variation of void ratio of sands used, the values of the coefficient of permeability varied considerably. There was a negative correlation between coefficient of permeability and void ratio.

  • PDF