Numerical study for performance analysis and design of a counterflow type cooling tower (대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구)

  • 이상윤;이정희;최영기;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

The Parallel Operation Control of Static UPSs (정지형 UPS의 병렬운전 제어)

  • Min, Byeong-Gwon;Won, Chung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF

Effects of Shoe Insole Height on Static and Dynamic Balance among Healthy Young Men (중창의 높이가 건강한 젊은 남성들의 정적 및 동적 균형에 미치는 영향)

  • Song, Geunchan;Park, Minji;Jo, Suyeon;Kim, Mirae;Jo, Eunjin;Kang, Soonhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.3 no.3
    • /
    • pp.49-57
    • /
    • 2015
  • Purpose : The purpose of this study was to identify whether static and dynamic balance in young men were influenced by the different height of insoles in their shoes. Methods : Eighteen healthy young men (mean $20.61{\pm}1.38years$) were recruited for this study. The subjects' static and dynamic balance were assessed while wearing three different height' insoles (0cm, 2cm, 3cm) in their tennis shoes. Anterioposterior (AP) and mediolateral (ML) sway velocity was measured for 20 seconds using a force plate (Good balance system, Finland) under four conditions including normal standing with eyes open and with eyes closed, and tandem standing with eyes open and with eyes closed. The Functional Reach Test (FRT) and Timed Up & Go (TUG) were also performed for each subject under each condition. Results : 1) ML and AP sway velocities in young men were significantly different according to the height of the insole in normal standing with eyes open and eyes closed. 2) ML and AP sway velocities in young men were not different according to the height of the insole in tandem standing with eyes open. 3) ML sway velocities in young men were significantly different according to the height of the insole in tandem standing with eyes closed, whereas AP sway velocities did not differ by height of the insole in tandem standing with eyes closed. 4) FRT scores in young men were significantly different according to the height of the insole. 5) TUG scores in young men were not significantly different according to the height of the insole. Conclusions : This study's results indicate that the static and dynamic balance in young men can be influenced by shoe insole height.

Optimal design and real application of nonlinear PID controllers (비선형 PID 제어기의 최적 설계및 실제 적용)

  • Lee, Moon-Yong;Koo, Doe-Gyoon;Lee, Jong-Min
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.639-643
    • /
    • 1997
  • This paper presents how nonlinear PID control algorithms can be applied on chemical processes for a more stable operation and perfect automation. A pass balance controller is designed to balance the exiting temperatures of a heater and a heat exchange network. The proposed controller has gain-varying integral action and deals with the operational constraints in an efficient manner. Also, the use of a PID gap controller is proposed to maximize energy saving and operation stability and to minimize operator intervention in operation of air fan coolers. The proposed controller adjusts the opening of a louver automatically in such a way that it keeps the air fan pitch position within the desired range. All these nonlinear PID controllers have been implemented on the distributed control system (DCS) for good reliability and operability. Operator acceptance was very high and the implemented controllers have shown good performance and high service factor still now on. The proposed methodology can be directly applied to similar processes without any modification.

  • PDF

The Effect of Turning Training on Figure of 8 Tract on Stoke Patients' Balance and Walking (8자 모양 트랙을 이용한 방향전환 훈련이 뇌졸중 환자의 균형 및 보행에 미치는 영향)

  • Kim, Mi-Gan;Kim, Joong-Hwi;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.143-150
    • /
    • 2012
  • Purpose: This study was intended to discover the effect of the turning training on figure of 8 tract on stroke patients' static and dynamic balance, as well as walking. Methods: A total of 42 stroke patients participated in this study. The training group was trained on the figure of 8 tract, while the control group was trained on the straight path for 30 minutes per day, for 4 weeks. Berg balance scale was used to measure the balance of the patients, before and after the training, and Good balance system was used to measure the sway speed and the distance of COG while standing. To measure the ability of walking, TUG and FSST were also used. Results: There were significant increases in the average score of Berg balance scale, in both groups after the training, and also significant difference between both groups were observed. The training group showed significant differences in the static balance ability, as well as anteroposterior and mediolateral sway speed. Further, there were significant increases in the dynamic balance ability, COP total distance, and TUG in both groups. The results showed more differences in comparing the control group with that of the training group. In FSST, there was no change in the control group, but there was a significant increase in the training group. Conclusion: Turning training on figure of 8 tract in stroke patients significantly increased the static and dynamic balance and walking ability. Based on the results, it can be seen that the training on the figure of 8 tract can influence the ability of balance and walking, which can lead to appropriate reactions to the change of environment and various tasks. Thus, it is assumed that turning training on figure of 8 tract as a means of improving the condition of stroke patients can be a meaningful program.

Development of Ergonomic Balance Seat(e-BASE) Chair

  • Park, Jae Hee;Kim, Seung Hee;Kim, Min Uk;Jung, Hanbum;Shim, Young Soo;Ryu, Taehee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.145-152
    • /
    • 2013
  • Objective: The aim of this study is to develop an ergonomic office chair that has an alarm function for the unbalanced sitting postures. Background: Contrary to expectation, it is reported that office workers sit on their chairs much more in unbalanced postures during daily work. Even though an office worker uses an ergonomically good-designed chair and begins their work in a good sitting posture, his/her posture is likely to shift to the unbalanced bad posture. Therefore, a posture alarm system would be very helpful in keeping office workers' good postures. Method: We developed a prototype chair with four load cells under a seat pan and one load cell beneath a backrest. Through some experiments, we set the criteria for unbalanced bad postures then implemented the criteria into the alarm system of the prototype chair. The chair called e-BASE chair could detect unbalance postures and show alarms for chair users. We also enhanced back support by developing a step-wised folding backrest. Results: The e-BASE chair showed better performance in interface pressure distributions and balanced posture ratio in VDT work. Conclusion: The ergonomic chair with posture alarm function(e-BASE chair) was developed. It showed better performance in seat pressure distribution and in keeping good posture during office work. Application: The posture alarm system and folding backrest can be applied to the new models of office chair.

Effect of Weight Bearing Exercise on Weight Bearing and Balance for Patients with Chronic Stroke (체중지지 훈련이 만성 뇌졸중 환자의 체중지지능력 및 균형에 미치는 영향)

  • Lee, Jong-Sik;Nam, Ki-Won;Kim, Kyung-Yoon;Yoon, Jang-Won;Park, Jong-Hang
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.4
    • /
    • pp.253-261
    • /
    • 2012
  • Purpose: In this study, the following experiment was conducted to see how to apply the sprinter pattern in proprioceptive neuromuscular facilitation (PNF) and functional weight bearing exercise affected balance capabilities and weight bearing among chronic stroke patients. Methods: The subjects included 27 subjects who had been diagnosed with hemiplegia due to stroke. A total of 12 sessions was held, 3 sessions a week over 4 weeks, were provided to the groups. The control group received general rehabilitation program, and the experimental group performed sprinter pattern in PNF or functional weight bearing exercise. The weight bearing capability and static balance capability test was implemented by using Good-Balance System and Frailty and Injuries Cooperative Studies of Intervention Techniques, while the dynamic balance capability test was carried out by using Four Square Step Test and Timed "Up and Go". Results: The paretic/nonparetic side weight bearing by application of each exercise showed that there were no significant differences in variation among each groups on before exercise, after exercise, 2 weeks after exercise. Static balance test by application of each exercise showed that there were significant differences after exercise and 2 weeks after exercise. Dynamic balance test by application of each exercise showed that there were significant differences after exercise and 2 weeks after exercise. Conclusion: To put the results together, the application of sprinter pattern and functional weight bearing exercise was effective in improving static and dynamic balance capabilities. Therefore, these exercises are helpful to improve balance in patients with stroke.

A Rotating Balance Design and Performance Estimation for a Rotor Test Jig (로터 실험 장치용 Rotating Balance의 설계 및 성능 검증에 관한 연구)

  • Ryi, Jae-Ha;Rhee, Wook;Choi, Jong-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.301-306
    • /
    • 2009
  • In this study a 3-component rotating balance, which is designed to measure the thrust (Fz) and two moment components (Mx, My) simultaneously for a rotor test jig, is designed and its performance is validated experimentally. The low voltage signal from the strain gages mounted on the balance is amplified with a rotating amplifier, which is then fed through a slip-ring unit into the data acquisition system. In order to validate the accuracy of the calibration matrix obtained from a static calibration test, an additional reaction type balance is used to measure the thrust from a model rotor simultaneously, and shows very good result. Finally, the expanded uncertainty value, which is obtained from ISO method is estimated to be $2.82\times10^{-1}$, and the balance turns out to be reliable.

Smartphone Based Standing Balance Evaluation Using Frequency Domain Analysis of Acceleration (가속도 주파수분석 방법을 이용한 스마트폰 기반 정적균형평가)

  • Hwang, Jisun;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2018
  • Background: At present time, smartphones have become very popular and powerful devices, and smartphone applications with the good validity have been designed to assess human balance ability. Objects: The purpose of this study is to evaluate the feasibility of smartphone acceleration in the assessment of postural control ability for six different conditions. Methods: Twenty healthy college-aged individuals volunteered. Static balance ability was measured twice with one-day interval using smartphone application and 3D motion capture system under the six different conditions. Results: Dominant frequencies for each test condition did not show significant differences except for two conditions. The intra-rater correlation coefficient between the first and second tests showed high correlations in six conditions(r>.70, p<.05). Smartphone acceleration and the acceleration calculated from the 3D marker position data showed high correlation coefficient(r>.80, p<.001). Conclusion: Acceleration recorded from a smartphone could be useful assessment variables for balance test in the clinical field.

Reliability and Concurrent Validity of the Balance Evaluation using Space Balance 3D and Tinetti Mobility Test in Subacute Stroke Patients (아급성 뇌졸중 환자에서 Space Balance 3D와 Tinetti Mobility Test를 이용한 균형 능력 평가의 신뢰도 및 동시타당도 연구)

  • Choi, Ji-Min;Lee, Jong-Hoon;Ha, Hyun-Geun;Kim, Yang-Gu;Kim, Yun-Hee;Bae, Young-Hyeon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.264-273
    • /
    • 2012
  • The purpose of this study was to determine the test-retest reliability and the concurrent validity between tinetti mobility test (TMT), berg balance scale (BBS) and space balance 3D which is one of the computerized measurement and visual feedback balance assessment system in subacute stroke patients. Twenty three ambulatory acute stroke subjects were measured the TMT, BBS and space balance 3D. The test-retest reliability(intra-class correlation coefficient: ICC) indicated that the static and dynamic balance in space balance 3D considered moderate reliability and TMT, BBS were good reliability. In case of concurrent validity, there were moderate validity (p<.01) between static balance test with space balance 3D and each TMT, BBS. But there were only poor validity (p<.05) between center to forward-left, center to backward-left phase in dynamic balance test with space balance 3D and each TMT, BBS. These findings suggest that in subacute stroke patients the test-retest reliability and concurrent validity using the space balance 3D and TMT were valuable in balance test but there was limitation to evaluate dynamic balance test.