Surface Analysis of Aluminum Bonding Pads in Flash Memory Multichip Packaging

  • Son, Dong Ju;Hong, Sang Jeen
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.221-225
    • /
    • 2014
  • Although gold wire bonding techniques have already matured in semiconductor manufacturing, weakly bonded wires in semiconductor chip assembly can jeopardize the reliability of the final product. In this paper, weakly bonded or failed aluminum bonding pads are analyzed using X-ray photoelectron spectroscopy (XPS), Auger electron Spectroscopy (AES), and energy dispersive X-ray analysis (EDX) to investigate potential contaminants on the bond pad. We found the source of contaminants is related to the dry etching process in the previous manufacturing step, and fluorocarbon plasma etching of a passivation layer showed meaningful evidence of the formation of fluorinated by-products of $AlF_x$ on the bond pads. Surface analysis of the contaminated aluminum layer revealed the presence of fluorinated compounds $AlOF_x$, $Al(OF)_x$, $Al(OH)_x$, and $CF_x$.

PREPARATION OF ANISOTROPIC CONDUCTIVE FINE PARTICLES BY ELECTROLESS NICKEL PLATING.

  • Fujinami, T.;Watanabe, J.;Motizuki, I.;Honma, H.
    • 한국표면공학회지
    • /
    • 제29권6호
    • /
    • pp.709-713
    • /
    • 1996
  • Mechanical solderless chip packaging with small gold bumps or metal balls has increased in the electronic devices. The preparation of conductive particles (5~7 $\mu\textrm{m}$ diamiter) by electroless nickel plating have been investigated. Generally, batch type electroless plating is applied to provide conductivity on the nonconductors. Since the surface areas of particles are much larger than the bulk substrate, accordingly the electroless plating bath becomes unstable. Thus, we applied the continuous dropping method for the preparation of conductive particles. The uniform coverage of deposited nickel on the particles was obtained by using ammonium acetate as a complexing agent, and surface coverage is further improved without coagulation of particles by the surface active agent treatment before enter the plating bath.

  • PDF

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

부 채널 신호에 대한 박막의 영향 (Thin Film Effects on Side Channel Signals)

  • 선용빈
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.51-56
    • /
    • 2013
  • Even if transmissions through normal channel between ubiquitous devices and terminal readers are encrypted, any extra sources of information retrieved from encrypting module can be exploited to figure out the key parameters, so called side channel attack. Since side channel attacks are based on statistical methods, making side channel signal weak or complex is the proper solution to prevent the attack. Among many countermeasures, shielding the electromagnetic signal and adding noise to the EM signal were examined by applying different thicknesses of thin films of ferroelectric (BTO) and conductors (copper and gold). As a test vehicle, chip antenna was utilized to see the change in radiation characteristics: return loss and gain. As a result, the ferroelectric BTO showed no recognizable effect on both shielding and adding noise. Cu thin film showed increasing shielding effect with thickness. Nanometer Au exhibited possibility in adding noise by widening of bandwidth and red shifting of resonating frequencies.

GPS 수신기용 역확산 지연 동기 루프의 FPGA 회로 구현과 성능 분석 (FPGA circuit implementation of despreading delay lack loop for GPS receiver and preformance analysis)

  • 강성길;류흥균
    • 한국통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.506-514
    • /
    • 1997
  • In this paper, we implement digital circuit of despreading delay lock loop for GPS receiver. The designed system consists of Epoch signal generator, two 13bit correlators which correlates the received C/A code and the locally generated C/A code in the receiver, the C/A code generator which generates C/A code of selected satellite, and the direct digital clock synthesizer which generates the clock of the C/A code generator to control the phase and clock rate, the clock controller, and the clock divider. The designed circuit has the function of the acquisition and tracking by the autocorrelation characteristics of Gold code. The controller generates each other control signals according to the correlation value. The designed circuit is simulated to verify the logic functional performance. By using the simulator STR-2770 that generates the virtual GPS signal, the deigned FPGA chip is verified the circuit performance.

  • PDF

표면 미세 가공기술을 이용한 마이크로 캔틸레버의 제작과 바이오센서로의 응용 (Fabrication of Microcantilever-based Biosensor Using the Surface Micromachining Technique)

  • 유경아;정승룡;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.11-15
    • /
    • 2006
  • We propose an optical and an electrical detection methods for detecting various bio-molecules effectively with microcantilevers. The microcantilevers were fabricated employing surface micromachining technique that has attractive advantages in terms of cost efficiency, simplicity and ability of fabricating in array. The fluid cell system for injection of bio-molecular solution is fabricated using polydimethylsiloxane (PDMS) and a fused silica glass. The microcantilever is deflected with respect to the difference of the surface stress caused by the formation of self-assembled bio-molecules on the gold coated side of the microcantilever. It detected cystamine dihydrochloride and glutaraldehyde molecules and analyzed individual concentrations of the cystamine dihydrochloride solution. We confirm that the deflections of bending-up or bending-down are occurred by the bio-molecule adsorption and microcantilever can be widely used to a ${\mu}-TAS$ and a lab-on-a-chip for a potential detection of various bio-molecules.

A Portable Surface Plasmon Resonance Biosensor for Rapid Detection of Salmonella typhimurium

  • Nguyen, Hoang Hiep;Yi, So Yeon;Woubit, Abdela;Kim, Moonil
    • Applied Science and Convergence Technology
    • /
    • 제25권3호
    • /
    • pp.61-65
    • /
    • 2016
  • Here, the rapid detection of Salmonella typhimurium by a portable surface plasmon resonance (SPR) biosensor in which the beam from a diode laser is modulated by a rotating mirror is reported. Using this system, immunoassay based on lipopolysaccharides (LPS)-specific monoclonal anti-Salmonella antibody was performed. For the purpose of orientation-controlled immobilization of antibodies on the SPR chip surface, the cysteine-mediated immobilization method, which is based on interaction between a gold surface and a thiol group (-SH) of cysteine, was adopted. As a result, using the portable SPR-based immunoassay, we detected S. typhimurium in the range from 10^7 CFU/mL to 10^9 CFU/mL within 1 hour. The results indicate that the portable SPR system could be potentially applied for general laboratory detection as well as on-site monitoring of foodborne, clinical, and environmental agents of interest.

살모넬라와 면역글로블린(hIgG)의 항원-항체반응 감지를 위한 표면 플라즈몬 공명형 센서시스템의 특성 (Characteristics of Constructed SPR (Surface Plasmon Resonance) Sensor System for the Detection of Salmonella and hIgG Antigen-Antibody Reaction.)

  • 엄년식;고광락;함성호;김재호;이승하;강신원
    • 센서학회지
    • /
    • 제7권4호
    • /
    • pp.263-270
    • /
    • 1998
  • 본 연구에서는 특정한 생물학적 의미를 갖는 물질들간의 결합 및 분리과정을 실시간에 측정하기 위해 빠른 응답특성과 높은 감도를 갖는 표면 플라즈몬 공명 (Surface Plasmon Resonance, SPR) 현상을 이용한 센서 시스템을 제작하였다. SPR 시스템의 프리즘 표면에 일정 두께의 금 박막이 진공증착된 센서칩을 두고 이 아래에 위치한 시료충전셀에 살모넬라 (salmonella) 항체를 주입시켜 항체가 센서칩 표면에서 자기집합 (self-assembly) 함에 따라 공명각이 변화하는 현상을 측정하였다. 이후 분석대상물질인 살모넬라 항원을 주입하여 항체와의 결합 상태를 일정 시간 간격을 두고 공명각의 변화로서 측정하고 이 결과를 분석하였다. 또한 human Immunglobulin G (hIgG)를 항원으로 한 항원-항체 반응 역시 살모넬라의 경우와 같은 방법으로 측정하였다. 그 결과 살모넬라의 항체는 센서칩 표면에서 약 10분 동안 자기집합하고 반응이 포화됨을 공명각의 변화를 통해 볼 수 있었으며, hIgG의 항체의 경우는 약 60분 동안 반응을 하고 포화됨을, 그리고 살모넬라와 hIgG의 항원 (분석대상물질) 은 모두 각각의 항체에 대해서 약 1분 이내에 결합하고 포화됨을 볼 수 있었다.

  • PDF

PCB의 ENIG와 OSP 표면처리에 따른 Sn-3.5Ag 무연솔더 접합부의 Electromigration 특성 및 전단강도 평가 (Effects of PCB ENIG and OSP Surface Finishes on the Electromigration Reliability and Shear Strength of Sn-3.5Ag PB-Free Solder Bump)

  • 김성혁;이병록;김재명;유세훈;박영배
    • 한국재료학회지
    • /
    • 제24권3호
    • /
    • pp.166-173
    • /
    • 2014
  • The effects of printed circuit board electroless nickel immersion gold (ENIG) and organic solderability preservative (OSP) surface finishes on the electromigration reliability and shear strength of Sn-3.5Ag Pb-free solder bump were systematically investigated. In-situ annealing tests were performed in a scanning electron microscope chamber at 130, 150, and $170^{\circ}C$ in order to investigate the growth kinetics of intermetallic compound (IMC). Electromigration lifetime and failure modes were investigated at $150^{\circ}C$ and $1.5{\times}10^5A/cm^2$, while ball shear tests and failure mode analysis were conducted under the high-speed conditions from 10 mm/s to 3000 mm/s. The activation energy of ENIG and OSP surface finishes during annealing were evaluated as 0.84 eV and 0.94 eV, respectively. The solder bumps with ENIG surface finish showed longer electromigration lifetime than OSP surface finish. Shear strengths between ENIG and OSP were similar, and the shear energies decreased with increasing shear speed. Failure analysis showed that electrical and mechanical reliabilities were very closely related to the interfacial IMC stabilities.

다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포 (Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses)

  • Kim, Sookil
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.83-88
    • /
    • 1999
  • 목적 : 금속박막과 고체 팬텀이 선량 분포와 선량 측정에 미치는 영향을 연구하기 위하여 TLD 실험을 행하였다. 본 연구의 목적은 주어진 고체 팬텀 환경 내에서 TLD 기판 위에 놓인 금속박막의 build-up 효과와 깊이선량 분포를 알아보고자 하였다. 대상 및 방법 : 측정은 TLD 기판과 같은 면적 (3.2 $\times$ 3.2 $\textrm{mm}^2$)의 금속박막을 LiF TLD-100 위에 얹어서 행하였다. 여러 종류 (주석, 구리, 금) 의 다양한 두께 (0.1, 0.15, 0.2, 0.3 mm)를 가진 금속박막 중에 한 개를 TLD 기판 위에는 얹어서 각 각의 흡수선량을 측정하였다. 금속박막을 얹은 TLD 기판을 사용하여 고체 팬텀에서의 표면홉수선량과 최대 build-up 영역에서 흡수선량을 측정하였다. 결과 : 금속박막을 이용한 TLD 기판의 경우 표면흡수선량이 증가하였고, 물에 대한 금속의 등가 두께에 따른 표면흡수선량 곡선에는 build-up 이 뚜렷이 관측되었다. 최대 build-up 영역에서 관측한 흡수선량 측정값은 금속박막을 없지 않은 TLD의 경우보다 약 8% 에서 13% 정도의 보다 작은 값을 나타내었다. 결론 : TLD 선량 측정 시 금속 박막 법은 깊이에 따른 흡수선량 뿐 만 아니라 피부 표면으로부터 약 4.2mm 깊이까지의 홉수선량의 build-up 에 관련 정보를 의료진에 제공할 수 있으며, 금속박막을 얹은 TLD에 관한 실험 결과는 피부 특정 영역에서의 bolus 의 결정에 도움이 될 것으로 사료됨.

  • PDF