• Title/Summary/Keyword: go

Search Result 12,257, Processing Time 0.036 seconds

Dynamic Power Management Method Considering VBR Video Traffic in Wi-Fi Direct (Wi-Fi Direct에서 VBR 비디오 트래픽을 고려한 동적 에너지 관리 기법)

  • Jin, Mei-Hua;Jung, Ji-Young;Lee, Jung-Ryun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.11
    • /
    • pp.2218-2229
    • /
    • 2015
  • Recently Wi-Fi Alliance defined Wi-Fi direct, which can communicate through a direct connection between the mobile device anytime, anywhere. In Wi-Fi direct, all devices are categorized by group of owner (GO) and client. Since portability is emphasized in Wi-Fi direct devices, it is essential to control the energy consumption of a device very efficiently. In order to avoid unnecessary power consumed by GO, Wi-Fi direct standard defines two power management schemes: Opportunistic power saving scheme and Notice Of Absence (NOA) scheme. But, these two schemes do not consider the traffic pattern, so we cannot expect high energy efficiency. In this paper, we suggest an algorithm to enhance the energy efficiency of Wi-Fi direct power saving, considering the characteristics of multimedia video traffic. Proposed algorithm utilizes the statistical distribution for the size of video frames and adjusts the length of awake interval dynamically. Also, considering the inter-dependency among video frames, the proposed algorithm assigns priorities to video frames and ensures that a video frame with high priority is transmitted with higher probability than other frames with low priority. Simulation results shows that the proposed method outperforms the traditional NOA in terms with average delay and energy efficiency.

A longitudinal study on the growth pattern of craniofacial skeleton in skeletal class III (골격성 제 III급 부정교합자의 두 개안모의 성장양상에 관한 누년적 연구)

  • Park, Young-Chel;Park, Min-Sung;Kim, Tae-Gyun
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.751-761
    • /
    • 1998
  • The purpose of this study was to find the characteristics of lateral crphalogram of skeletal class III malocclusion patients to whom orthognathic surgery was essential. For this study 37 patients with skeletal class III and going to treat or be treated orthognathic surgery(age 7-17) were selected to experimental group and 56 people with normal occlusion (age 8-13) were selected to normal group and the two groups were evaluated and statistically analyzed and the results were as follows 1. In comparison of experimental group and normal group in prepubertal group, there were significant differences in ANS-U1/Me-L1, Mx. Length/Mn. Length, S-N/Go-Me, Wits, ANB, SN-Pog, IMPA, Facial Convexity, APDI (p<0.05) 2. In comparison of experimental group and normal group in pubertal group, there were significant differences in ANS-U1/Me-L1, S-Go/N-Me, Mx.Length/Mn.Length, S-N/Go-Me, Wits, Saddle Angle, SNB, ANB, SN-Pog, IMPA, Interincisal Angle, Facial Convexity, APDI (p<0.05) 3. Among items showing characteristics of skeletal class III malocclusion, there were no significant differences between prepubertal group and pubertal group in other items except Mx. Length/Mn. Length,APDI (p<0.05) 4. The significant correlationship was the highest between Saddle Angle and SNB, SN-Pog and SNB, ANB and Facial Convexity in experimental group

  • PDF

A methodology for Predicting Equity Input Timing/Amount for Decision Making of Financing Apartment Housing Projects - From the Perspective of Mid-sized Construction Companies - (공동주택 PF사업 참여 의사결정을 위한 자기자본 투입 시점/규모 예측방법론 - 중견 건설사의 관점에서-)

  • Yoo, Jinhyuk;Cha, Heesung;Shin, Dongwoo;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.2
    • /
    • pp.21-30
    • /
    • 2016
  • The current PF project is entirely relying on construction company's credibility. As such, it has increased a negative and bad recognition in domestic real estate economy. In addition, PF experts has a perception that a project's safety of future cash flow profitability is more important than the construction company's credibility. So many PF experts make an effort in order to set aside safe project structure of PF and analyse systematically the risks of the project. In common feasibility study of the PF Project, financial specialists and real estate specialists are forecasting and evaluating the suitability of the project through reviewing the development profit from the project of sales. However, cash flow analysis and evaluation from the perspective of mid-sized construction companies are still in the primary level. Therefore, this study has analysed the current feasibility study and go/no go decision making procedures. Then the authors have a new cash flow analysis method from the perspective of mid-sized construction companies, by improving the feasibility study and go/no go decision making procedures.

Development of Conductive Polycaprolactone (PCL)-resin based on Reduced Graphene Oxide(rGO)/Polypyrrole (Ppy) composite for 3D-printing application (3D 프린팅 응용을 위한 환원그래핀/폴리피롤 복합체 기반의 전도성 폴리카프로락톤 레진의 개발)

  • Jeong, Hyeon Taek;Jung, Hwa Yong;Cho, Young Kwang;Kim, Chang Hyeon;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.935-939
    • /
    • 2018
  • 3D Printing technology is developing in various prototypes for medical treatment, food, fashion as well as machinery and equipment parts production. 3D printing technology is also able to fully be utilized to other industries in terms of developing its technology which has been reported in many field of areas. 3D printing technology is expected to be used in various applications related to $4^{th}$ industrial revolution such as finished products and parts even it is still carried out in the prototype model. In this study, we have investigated and developed conductive resin for 3d printing application based on reduced graphene oxide(rGO)/Polypyrrole(Ppy) composite and polycaprolactone(PCL) as a biodegradable polymer. The electrical properties and surface morphology of the conductive PCL resin based on therGO/Ppy composite were analyzed by 4point-probe and scanning electron microscope(SEM). The conductive PCL resin based on rGO/Ppy composite is expected to be applicable not only 3D printing, but also electronic materials in other industrial fields.

Power Cost Analysis of Go-ri Nuclear Power Plant Units 1 and 2

  • Chung, Chang-Hyun;Kim, Chang-Hyo;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.101-116
    • /
    • 1976
  • An attempt is made to analyze the unit nuclear power cost of the Go-ri units 1 and 2 in terms of a set of model data. For the calculational purpose, the power cost is first decomposed into the cost components related to the plant capital, operation and maintenance, working capital requirements, and fuel cycle operation. Then, POWERCO-50 computer code is applied to enumerate the first three components and MITCOST-II is used to evaluate the fuel cycle cost component. The specific numerical results are the fuel cycle cost of Go-ri unit 2 for three alternative fuel cycles presumed, levelized unit power cost of units 1 and 2, and the sensitivity of the power cost to the fluctuation of the model data. Upon comparision of the results with the power cost of the fossil power plants in Korea, it is found that the nuclear power is economically preferred to the fossil power. Nevertheless, the turnkey contract value of Go-ri unit 2 appears to be rather expensive compared with the available data on the construction cost of the PWR plants. Therefore, it is suggested that, in order to make the nuclear power plants more attractive in Korea, the unfavorable contract of such kind must be avoided in the future introduction of the nuclear power plant. Capacity factor is of prime importance to achieving the economic generation of the nuclear electricity from the Go-ri plant. Therefore, it is concluded that more efforts should be directed to make the maximum use of the Go-ri plant.

  • PDF

A study on the Characteristics of Structural Proportion of Pillar and 'Kong-po' in 'Main Hall of Royal Palace(正殿)' of the Royal Palace (궁궐(宮闕) 정전(正殿)에서 기둥과 공포의 구조적(構造的) 비례특성(比例特性)에 관한 연구(硏究))

  • Park, Eon-Kon;Choi, Hyo-Sik
    • Journal of architectural history
    • /
    • v.14 no.1 s.41
    • /
    • pp.71-87
    • /
    • 2005
  • 4 royal palaces are currently remained from capital city (Seoul) of 'Cho-Sun(朝鮮)' period. In these palaces, 'Main hall of Royal Palace(正殿)' is the center of the Royal Palaces. The 'Main hall of Royal Palace' of the Royal Palace was the best building of that time. Therefore there were many studies about the 'Main hall of Royal Palace'. But these studies were individual studies of these 'Main hall of Royal Palace'. Therefore, this study is to analyze and compare 4 'Main hall of Royal Palace' of the Royal palaces. It is to study the proportion regarding the Diameter of the pillar, the Height, the pillar and pillar Interval's Distance, and the arrangement of 'Kong-Po(bracket sets)'. With these studies, it is to prove that the 'Main hall of Royal Palace' is the building which high construction technique of this time is expressed. Result of this study is as followings; First, the proportion of pillar height(H) to its diameter(D) average from H=8.0 to 8.5D. Only the Myeong-Jeong-Jeon omitted the 'Go-Ju(高柱)' in the 'Toi-Kan (退間)' to place Ea-Jwa(御座). Second, Second, the proportion of diameter of the pillar of 'Eoi-Bu-Pyeong-Ju(外部平柱)' and 'Nae-Jin-Go-Ju(內陣高柱)' average D1(Diameter of 'Eoi-Bu-Pyeong-Ju') =0.91D2 (Diameter of 'Nae-Jin-Go-Ju'). In regards to the height, the single floor 'Main hall of Royal Palace' and double floor 'Main hall of Royal Palace' seems to be different. The height proportion of the double floor 'Main hall of royal palace' is H1(Height of 'Eoi-Bu-Pyeong-Ju')=0.34H2(Height of 'Nae-Jin-Go-Ju') and single floor 'Main hall of Royal Palace' has a proportion of H1=0.62H2. Third, in Geun-Jeong-Jeon, with the proportion of height and diameter of the pillar, interval's distance between pillars and diameter, the pillar interval distance and height, of 'Ea-kan(御間)' from the 'Toi-Kan' is different from 'Main hall of Royal Palace'. This is because the structure of 'Toi-Kan' of Geun-Jeong-Jeon is not stable. In order to reinforce this, 'Gui-Go-Ju(隅高柱)' of the Geun-Jeong-Jeon jut out $4{\sim}7%$ more compared to In-Jeong-Jeon. Fourth, when comparing double floor 'Main hall of royal palace' of Geun-Jeong-Jeon and In-Jeong-Jeon, based on distance of 'Eoi-Bu-Pyeong-Ju' and 'Nae-Jin-Go-Ju' of lower level, the 'Sang-Bu-Pyeong-Ju(上部平柱)' of Geun-Jeong-Jeon jut out $4{\sim}7%$ more compared to the In-Jeong-Jeon and also It becomes thicker. Fifth, the arrangement of 'Kong-Po' on the front row of 'Gan(間)' had to do with the change of side 'Gan'. Even though the Geun-Jeong-Jeon and the In-Jeong-Jeon were double floors, the arrangement of the 'Kong-Po' is different because the number of side bay is different.

  • PDF