• Title/Summary/Keyword: global air temperature

Search Result 334, Processing Time 0.023 seconds

Investigation of Urban High Temperature Phenomenon in Summer using the High Density Ground Monitoring System in Daegu Metropolitan Area (지상 고밀도 관측 시스템을 이용한 대구의 여름철 고온현상 조사)

  • Kim, Sang-Heon;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1619-1626
    • /
    • 2014
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network in Daegu metropolitan city, the representative basin-type city in Korea, in summer, 2013. We used a total of 28 air temperature observation points data(16 thermometers and 12 AWSs). From the distribution of monthly average air temperature, air temperature at the center of Daegu was higher than the suburbs. Also, the days of daily minimum air temperature more than or equal to $25^{\circ}C$ and daily maximum air temperature more than or equal to $35^{\circ}C$ at the schools near the center of Daegu was more than those at other schools. This tendency appeared more clearly on the days of daily minimum air temperature more than or equal to $25^{\circ}C$. Also, the air temperature near the center of the city was higher than that of the suburbs in the early morning. Thus it was indicated that the air temperature was hard to decrease as the bottom of the basin. From these results, the influence of urbanization to the formation of the daily minimum temperature in Daegu was indicated.

High Performance of Temperature Gradient Chamber Newly Built for Studying Global Warming Effect on a Plant Population

  • Lee, Jae-Seok;Tetsuyuki Usami;Takehisa Oikawa;Lee, Ho-Joon
    • The Korean Journal of Ecology
    • /
    • v.23 no.4
    • /
    • pp.293-298
    • /
    • 2000
  • To study the effect of global warming on the growth of plants and plant populations throughout their life cycle under a field-like condition, we constructed a Temperature Gradient Chamber (TGC) in Tsukuba, Japan. The chamber had slender shape : 30 m long. 3 m wide, and 2.5 m high. That satisfactory performance was confirmed by a test throughout all seasons in 1998: the projected global warming condition in the near future was simulated. That is, independent of a great daily or seasonal change in ambient meteorological conditions, air temperatures at the air outlet were warmed 5$^{\circ}C$ higher than those at the ambient (the annual mean was 14.3$^{\circ}C$) with precision of ${\pm}$0.2$^{\circ}C$ (the annual means were 19.2$^{\circ}C$) with a rising rate of approximately 1$^{\circ}C$ every 5 m. This chamber will enable us to study the effects of global warming on growth of plants and plant populations because their abilities to control air temperature are excellent. TGC is expected that it would be utilized for studying the effect of global warming on plant growth under natural weather conditions.

  • PDF

Spatial Distribution of Air Temperature during an Extreme Heat Period in Daegu Metropolitan Area in 2016 (2016년 여름철 폭염 시기 대구의 기온공간분포 특성)

  • Kim, Ji-Hye;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1023-1029
    • /
    • 2017
  • We studied the distribution of air temperature using the high density urban climate observation network data of Daegu. The observation system was established in February 2013. We used a total of 38 air temperature observation points (23 thermometers and 18 AWSs). From the distribution of monthly averaged air temperatures, air temperatures at the center of Daegu were higher than in the suburbs. The daily minimum air temperature was more than or equal to $25^{\circ}C$ and the daily maximum air temperature was more than or equal to $35^{\circ}C$ at the elementary school near the center of Daegu. Also, we compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas were faster than in urban areas. This is mainly due to the difference in surface heat capacity. These results indicate the influence of urbanization on the formation of the daily minimum temperature in Daegu.

Experimental Study on Light Oil Combustion Characteristics With High-Preheated Air (고온의 예열공기를 이용한 액체연료 분무특성에 관한 실험적 연구)

  • Park, Min-Chul;Oh, Sang-Hun
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.42-50
    • /
    • 2001
  • An experimental study has been carried on high-preheated temperature air combustion. Because the flames with high-preheated temperature air combustion were much more stable and homogeneous(both temporally and spatially) as compared to the room-temperature combustion air. The global flame feature showed range of flame colors (yellow, blue, blurish-green) over the range of conditions. Low level of NOx along with low level of CO have been obtained under high-preheated air combustion conditions. The thermal and chemical behavior of high-preheated air combustion flames depends on preheated temperature and oxygen concentration air.

  • PDF

Diurnal Variations in the Horizontal Temperature Distribution using the High Density Urban Climate Observation Network of Daegu in Summer (고밀도 도시기후관측 망 자료를 이용한 대구의 여름철 기온 수평 공간 분포의 일변화)

  • Kim, Sang-Hyun;Kim, Baek-Jo;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.259-265
    • /
    • 2016
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network of Daegu in summer, 2013. We compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas are faster than in urban areas. It is mainly due to the difference of surface heat capacity. In addition, local wind circulation also affects the discrepancy of thermal spatiotemporal distribution in Daegu. Namely, the valley and mountain breezes affect diurnal variation of horizontal distribution of air temperature. During daytimes, the air(valley breeze) flows up from urban located at lowlands to higher altitudes of rural areas. The temperature of valley breeze rises gradually as it flows from lowland to upland. Hence the difference of air temperature decreases between urban and rural areas. At nighttime, the mountains cool more rapidly than do low-lying areas, so the air(mountain breeze) becomes denser and sinks toward the valleys(lowlands). As the result, the air temperature becomes lower in rural areas than in urban areas.

Recent Changes in Solar Irradiance, Air Temperature and Cloudiness at King Sejong Station, Antarctica (남극 세종기지에서 최근 태양 복사, 기온과 운량의 변화)

  • Lee, Bang Yong;Cho, Hi Ku;Kim, Jhoon;Jung, Yeon Jin;Lee, Yun Gon
    • Atmosphere
    • /
    • v.16 no.4
    • /
    • pp.333-342
    • /
    • 2006
  • The long-term trends of global solar irradiance, air temperature, specific humidity and cloudiness measured at King Sejong station, Antarctica, during the period of 1988-2004, have been investigated. A statistically insignificant decrease, -0.21 $Wm^{-2}yr^{-1}$ (-0.26 %$yr^{-1}$, P<0.5) in global solar irradiance was found in an analysis from the time series of the monthly mean values, except for the increasing trends only in two months of January and June. The trends in irradiance are directly and inversely associated with the cloudiness trends in annual and monthly means. The trends in surface air temperature show a slight warming, $0.03^{\circ}Cyr^{-1}$ (1.88 %$yr^{-1}$, P<0.5) on the annual average, with cooling trend in the summer months and the warming in the winter. The exact relationship, if any, between the irradiance and temperature trends is not known. No significant tendency was found in specific humidity for the same periods. Recent (1996-2004) erythermal ultraviolet irradiance shows decreasing trend in annual mean, -0.15 $mWm^{-2}yr^{-1}$ (-1.18 %$yr^{-1}$, P<0.1) which is about five times the trends of global solar irradiance. The ratio of erythermal ultraviolet to global solar irradiance shows remarkable seasonal variations with annual mean value of 0.01 % and a peak in October and November, showing the increase of ultraviolet irradiance resulting from the Antarctic ozone hole. The sensitivity of global solar irradiance to the change in cloudiness is roughly $13%oktas^{-1}$ which is about twice of the value at the South Pole due to the difference in the average surface reflectance between the two stations. Much more sensitive values of $59%oktas^{-1}$ was found for erythermal UV irradiance than for the global solar irradiance.

Numerical Study on the Impact of Regional Warming on the Meterological Field and Ozone Concentration over the South-Eastern Part of the Korean Peninsula (기후변화에 따른 기온상승이 한반도 동남지역 국지 기상장과 오존 분포에 미치는 영향에 관한 수치모의)

  • Jeong, Yeo-Min;Lee, Hwa-Woon;Lee, Soon-Hwan;Choi, Hyun-Jung;Jeon, Won-Bae
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1431-1445
    • /
    • 2010
  • In order to clarify the impact of regional warming on the meteorological field and air quality over southeastern part of Korean Peninsula, several numerical experiment were carried out. Numerical models used in this study are WRF for the estimate the meteorological elements and CMAQ for assessment of ozone concentration. According to the global warming impact, initial air temperature were changed and its warming rate reach at 2 degree which was based on the global warming scenarios provided by IPCC. The experiments considering the global warming at initial stage were presented as case T_UP. Air temperature over inland area during night time for case T_UP is higher than that for Base case. During time since the higher temperature over inland area is maintained during daytime more intensified sea breeze should be induced and also decrease the air temperature in vicinity of coast area. In case of T_UP, high level concentrations ozone distribution area was narrowed and their disappearance were faster after 1800LST. As a results, wind and temperature fields due to the global warming at initial stage mainly results in the pattern of ozone concentration and its temporal variation at South-Eastern Part of the Korean Peninsula.

The Prediction of Water Temperature at Saemangeum Lake by Neural Network (신경망모형을 이용한 새만금호 수온 예측)

  • Oh, Nam Sun;Jeong, Shin Taek
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2015
  • The potential impact of water temperature on sea level and air temperature rise in response to recent global warming has been noticed. To predict the effect of temperature change on river water quality and aquatic environment, it is necessary to understand and predict the change of water temperature. Air-water temperature relationship was analyzed using air temperature data at Buan and water temperature data of Shinsi, Garyeok, Mangyeong and Dongjin. Maximum and minimum water temperature was predicted by neural network and the results show a very high correlation between measured and predicted water temperature.

Past and Future Temperature and Precipitation Changes over Korea using MM5 Model

  • Oh, Jai-Ho;Min, Young-Mi;Kim, Tae-Kook;Woo, Su-Min;Kwon, Won-Tae;Baek, Hee-Jeong
    • Proceedings of the Korean Quaternary Association Conference
    • /
    • 2004.06a
    • /
    • pp.29-29
    • /
    • 2004
  • Long term observational analysis by climatologists has confirmedthat the global warming is no longer a topic of debate among scientists andpolicy makers. According to the report of IPCC-2001 (Intergovernmental Panelon Climate Change), the global mean surface air temperature is increasinggradually. The reported increase of mean temperature is by 0.6 degree in the end of twentieth century. This could represent severe threat for propertylosses especially due to increase in the number of extreme weather arising out of global warming. period of model integration from 2001 to 2100 using output of ECHAM4/HOPE-G of Max Planet Institute of Meteorology (MPI) for IPCC SRES (Special Report on Emission Scenarios). The main results of this study indicate increase of surface air temperature by 6.20C and precipitation by 2.6% over Korea in the end of 21st century. Simulation results also show that there is increase in daily maximum and minimum temperatures while decrease in diurnal temperature range (DTR). DTR changes are diminished mainly due to relatively rapid increase of daily minimum temperature than that of daily maximumtemperature. It has been observed that increase in precipitation amount anddecrease in the number of rainy days lead to increase of pre precipitationintensity.

  • PDF

Correlation and Hysteresis Analysis of Air-Water Temperature in Four Rivers: Preliminary study for water temperature prediction (우리나라 하천의 기온-수온의 상관관계 및 이력현상 분석: 미래 하천수온 변화 예측을 위한 사전검토)

  • An, Ji-Hyuck;Lee, Khil-Ha
    • Journal of Environmental Policy
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2013
  • The potential impact of water temperature on air temperature in response to recent anthropogenic global warming has been noticed. To predict climate, induced change in river aquatic environment, it is necessary to understand the thermal constrains of fish species and the timing of the projected river temperature. As a preliminary study, air-water temperature relationship was analyzed on the basis of the observed data during the time period of 2009-2011 and the number of data corresponds to 873-1083. As a result of analyzing the auto-and cross-correlation coefficient between air-water temperature, high correlation is shown (~0.9). It is also found that the correlation coefficient of air temperature is higher than that of water temperature at the lag time less than approximately 10 days. Observed data was divided into two groups to investigate hysteresis: rising limb and falling limb. For some stations there is strong evidence that hysteresis exist between air-water temperature relationships. Consequently it is recommended that seasonal hysteresis needs to be included in determining an airwater relationship.

  • PDF