• Title/Summary/Keyword: glass penetration

Search Result 111, Processing Time 0.026 seconds

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS (섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구)

  • Kim, Sun-Jong;Shin, Sang-Wan;Han, Jung-Suk;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF

Study on Peridynamic Interlayer Modeling for Multilayered Structures (가상 절점을 이용한 적층 구조물의 페리다이나믹 층간 결합 모델링 검토)

  • Ahn, Tae Sik;Ha, Youn Doh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.389-396
    • /
    • 2017
  • Peridynamics has been widely used in the dynamic fracture analysis of brittle materials. Recently, various crack patterns(compact region, floret, Hertz-type crack, etc.) of multilayered glass structures in experiments(Bless et al. 2010) were implemented with a bond-based peridynamic simulation(Bobaru et al.. 2012). The actual glass layers are bound with thin elastic interlayer material while the interlayer is missing from the peridynamic model used in the previous numerical study. In this study, the peridynamic interlayer modeling for the multilayered structures is proposed. It requires enormous computational time and memory to explicitly model very thin interlayer materials. Instead of explicit modeling, fictitious peridynamic particles are introduced for modeling interlayer materials. The computational efficiency and accuracy of the proposed peridynamic interlayer model are verified through numerical tests. Furthermore, preventing penetration scheme based on short-range interaction force is employed for the multilayered structure under compression and verified through parametric tests.

Moisture Absorption Characteristics of Pt/Nafion Membrane for PEMFC Prepared by a Drying Process (건식법에 의해 제조한 PEMFC용 Pt/나피온 막의 흡습 특성)

  • Lee, Jae-Young;Lee, Hong-Ki
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.4
    • /
    • pp.310-315
    • /
    • 2012
  • A simple drying process was developed for the preparation of a Pt/Nafion self-humidifying membrane to be used for a proton-exchange membrane fuel cell (PEMFC). Platinum (II) bis (acetylacetonate), $Pt(acac)_2$ was sublimed, penetrated into the surface of a Nafion film and then reduced to Pt nanoparticles simultaneously without any support of a reducing agent in a glass reactor at $180^{\circ}C$ for 15 min. The process was carried out in $N_2$ atmosphere to prevent the oxidation of Pt nanoparticles at high temperature. The morphology and distribution of the Pt nanoparticles were observed by transmission electron microscopy (TEM) and energy dispersive spectroscopy (EDS), and we found that the average Pt particle size was ca. 3.7 nm, the penetration depth was ca. $17{\mu}m$. Almost all Pt nanoparticles were formed just beneath the surface and the number density decreased rapidly as the penetration depth increased. To estimate water absorption characteristics of the Nafion membranes, water uptake at an isothermal condition was measured by dynamic vapor sorption (DVS), and it was found that water uptake of the Pt/Nafion membrane was higher than that of the neat Nafion membrane.

The Prevention Effect of Seawater Penetration of Gel Coat Applied in Repair of FRP Fishing Vessel (FRP 어선 보수에 적용되는 겔코트의 해수 침투 방지 효과)

  • Kang, Dae Kon;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • Ships may collide with reefs or other objects during operation, when arriving or departing ports. The hull plate may be damaged due to the contact with other ships. The total number of domestic powered fishing vessels has decreased, but that of FRP fishing vessels has increased by 0.7% and the ratio of FRP fishing vessels to the total fishing vessels increased to 96%. Recently, fishing vessels has been used as fishing boats for income of non-fishermen as well as fishermen. Therefore, safety management for repair and maintenance is necessary. The penetration of moisture and moisture in the composite material such as FRP may deteriorate the mechanical properties and the salt (NaCl) component of the damaged portion may cause a relatively high deterioration in material strength. The gel coat painting is the final stage of repairs ans maintenance of FRP fishing vessels. The thickness criteria in the domestic and foreign gel coat is 0.3~0.762 mm. The joint specimens, which was immersed in seawater for 120 days, were compared with those without seawater immersion. As a result, the tensile strength was 83 ~ 121.8% and the flexural strength was 83 ~ 113% compared with the specimens without seawater immersion. According to the previous study the tensile strength decreased by more than 29% and the flexural strength decreased by more than 50% when the composite material was immersed in seawater for 1,083 hours without coating. As a result, it was found that the gel coat with 0.5 mm thickness is very effective in preventing the strength decrease of the composite material.

Development and Verification of 4-Electrode Resistivity Probe (4전극 전기비저항 탐사장비의 개발 및 검증)

  • Kim, Joon-Han;Yoon, Hyung-Koo;Jung, Soon-Hyuck;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3C
    • /
    • pp.127-136
    • /
    • 2009
  • The objective of this study is the development and verification of the 4-electrode resistivity probe (4ERP) for the estimation of electrical properties of the saturated soils. The 4ERPs with wedge and plane types are manufactured to obtain the electrical resistivity without polarization at the electrodes by using Wenner array. The wedge type is for the penetration into the soil samples and the plane type is for the installation into the cells used for the laboratory tests. The consolidation tests are carried out by using 6 types of glass beads and 3 types of sands in size. The test results show that the electrical resistivity increases with a decrease in the porosity, and the constant m used in Archie's law is dependent on the particle shape rather particle size. The one dimensional liquefaction tests show that the porosity obtained by the 4ERP is similar to that determined by the volume fraction. The penetration of the 4ERP into the large scale calibration chamber produces the resistivity profiles. This study demonstrates that the 4ERP may effectively estimate the porosity of the saturated soils.

COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS (강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구)

  • Park, Hye-Yang;Oh, Nam-Sik;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

Test and Numerical Analysis for Penetration Residual Velocity of Bullet Considering Failure Strain Uncertainty of Composite Plates (복합판재의 파단 변형률 불확실성을 고려한 탄 관통 잔류속도에 대한 시험 및 수치해석)

  • Cha, Myungseok;Lee, Minhyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.281-288
    • /
    • 2016
  • The ballistic performance data of composite materials is distributed due to material inhomogeneity. In this paper, the uncertainty in residual velocity is obtained experimentally, and a method of predicting it is established numerically for the high-speed impact of a bullet into laminated composites. First, the failure strain distribution was obtained by conducting a tensile test using 10 specimens. Next, a ballistic impact test was carried out for the impact of a fragment-simulating projectile (FSP) bullet with 4ply ([0/90]s) and 8ply ([0/90/0/90]s) glass fiber reinforced plastic (GFRP) plates. Eighteen shots were made at the same impact velocity and the residual velocities were obtained. Finally, simulations were conducted to predict the residual velocities by using the failure strain distributions that were obtained from the tensile test. For this simulation, two impact velocities were chosen at 411.7m/s (4ply) and 592.5m/s (8ply). The simulation results show that the predicted residual velocities are in close agreement with test results. Additionally, the modeling of a composite plate with layered solid elements requires less calculation time than modeling with solid elements.

AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE ACCORDING TO THE FILLING METHOD OF THE ESTHETIC MATERIALS IN CLASS V CAVITIES (V급 와동에서 심미성 수복재의 충전 방법에 따른 변연누출에 관한 실험적 연구)

  • Park, Jin-Young;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.217-227
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal leakage of esthetic restorative materials according to the filling method in class V cavities. 60 cavities were prepared on buccal surface for dye penetration test and divided into 5 experimental groups according to the filling methods of esthetic materials: group 1 was filled with glass ionomer cement, group 2, 3 and 4 were filled with the chamfer, knife edge and butt joint shaped glass ionomer cement respectively and silux plus/scotchbond 2$^{(R)}$ by sandwich technique, group 5 was lined with Dycal$^{(R)}$ and filled with silux plus/scotchbond 2$^{(R)}$ by bulk filling technique. All the specimens were then thermocycled in a range of $4^{\circ}C-60^{\circ}C$ by and immersed in 2% methylene blue dye solution for 24 hours, and sectioned mesiodistally with carborundum disk into two parts under water spray. All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The obtained results were as follows : 1. At the occlusal margins, group 2, 3, 4 and 5 showed less marginal leakage than group 1 (p<0.05) and there were not significant differences among group 2, 3, 4, and 5. 2. At the gingival margins, group 5 showed the least marginal leakage and group 4 and 5 showed less marginal leakage than group 1, 2 and 3 (p<0.05). 3. In the laminated groups, group 4 showed less marginal leakage than group 2 and 3 at the gingival margins. 4. In comparison to the occlusal and gingival margins, all groups showed less marginal leakage at the occlusal margins than at the gingival margins (p<0.05).

  • PDF

Impact Damage of Honeycomb Sandwich Antenna Structures (통신 안테나용 허니콤 샌드위치 구조물의 충격 손상에 관한 연구)

  • 조성재;김차겸;박현철;황운봉
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.74-77
    • /
    • 2001
  • The impact response and damage of CLAS panel was investigated experimentally. The facesheet material used was RO4003 woven-glass hydrocarbon/ceramic and the core material was Nomex honeycomb with a cell size of 3.2mm and a density of 96 kg/$\textrm{m}^{3}$. The shield plane used was RO4003 and 2024-T3 aluminum. Static indentation and impact test was conducted to characterize the type and extent of the damage observed in two CLAS panels, and the performance of antenna used in a wireless LAN system. Correlation of peak contact force, residual indentation and the delamination area shows impact damage of the panel with an aluminum shield plane is larger than that of the panel with RO4003 shield plane, although tile former is more penetration resistant. The damage was observed by naked eye, ultrasonic inspection and cross sectioning. The shape and size of delamination was estimated by ultrasonic inspection, and the area of delamination linearly increases as impact energy increases. The performance of impact damaged antenna was estimated by measuring return loss and radiation pattern.

  • PDF

Fast and Low Temperature Deposition of Polycrystalline Silicon Films by Hot Wire CVD (Hot Wire CVD를 이용한 다결정 Si 박막의 고속 저온 증착)

  • Lee, Jeong-Chul;Kang, Ki-Whan;Kim, Seok-Ki;Yoon, Kyung-Hoon;Song, Jin-Soo;Park, I-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1427-1429
    • /
    • 2001
  • Polycrystalline silicon(poly-Si) films are deposited on low temperature glass substrate by Hot-Wire CVD(HWCVD). The structural properties of the poly-Si films are strongly dependent on the wire temperature($T_w$). The films deposited at high $T_w$ of 2000$^{\circ}C$ have superior crystalline properties; average lateral grain sizes are larger than $1{\mu}m$ and there at·e no vertical grain boundaries. The surface of the high $T_w$ samples are naturally textured like pyramid shape. These large grain size and textured surface are believed to give high current density when applied to solar cells. However, the poly-si films are structurally porous and contains high defect density, by which high concentration of C and O resulted within the films by air-penetration after removed from chamber.

  • PDF