• Title/Summary/Keyword: glass fiber filters

Search Result 30, Processing Time 0.031 seconds

The Study on Characteristics of Collected Filter as Analysis of Carbon in Airborne Particulate Matters by Elemental Analyzer (원소분석기를 사용한 부유입자상물질중의 탄소성분 분석시 포집여지의 특성에 관한 연구)

  • 황경철;조기철;최종욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 1995
  • In order to study of characteristics of collected filter as analysis of carbon in airborne particulate matters by Elemental Analyzer, quartz fiber filter and glass fiber filter were used. The results are followed as; There was no difference of confidence in collection rate of airborne particulate matters between quartz fiber filter and glass fiber filter. Airborne particulate matters were collected on both filters evenly and the use of quartz fiber filter is better than glass fiber filter as analysis of carbon by thermal method.

  • PDF

Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation (도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구)

  • 이병규;신용철
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

Analytical Variability of Airborne Man-made Mineral Fibers by Phase Contrast Microscopy (위상차 현미경법에 의한 인조광물섬유 분석 변이)

  • Shin, Yong Chul;Yi, Gwang Yong;Kim, Boowook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.134-139
    • /
    • 2012
  • Objectives: This study was conducted to study the analytical variability of A & B counting rules in counting using a phase contrast microscope airborne fibers collected on filters in man-made mineral or vitreous fibers (MMMFs) industries. Methods: Fibers in filters were counted using A & B rules of NIOSH Method 7400. Intra-counter and inter-counter variations by fiber type and density were obtained. The types of MMMFs analyzed were glass wool fiber, rock wool fiber, slag wool fiber, and refractory ceramic fibers. The densities of fibers classified were <20 $fibers/mm^2,$ 20 - <50 $fibers/mm^2$, 50 - <100 $fibers/mm^2,$ and ${\geq}100$ $fibers/mm^2,$ respectively. Results: Intra-counter relative standard deviations by rule A were 0.084, 0.102, 0.071 for glass wool fibers, rock wool fibers and refractory ceramic fibers, and those by rule B were 0.139, 0.120 and 0.142, respectively. Inter-counter relative standard deviations by rule A were 0.281, 0.296, 0.180 for glass wool fibers, rock wool fibers and refractory ceramic fibers, and those by rule B were 0.396, 0.337 and 0.238, respectively. Conclusions: Intra-counter variation was not different significantly among fiber types (p>0.05), but B rule variation for ceramic fibers approximately 2 times greater than corresponding A rule estimates, and intra-counter and inter-counter variations were higher in the low fiber density.

The Holding Characteristics of the Glass Filter Separators of Molten Salt Electrolyte for Thermal Batteries (열전지용 용융염 전해질의 유리필터분리판의 담지특성)

  • Cho, Kwang-Youn;Riu, Doh-Hyung;Huh, Seung-Hun;Shin, Dong-Geun;Kim, Hyoun-Ee;Cheong, Hae-Won;Cho, Sung-Baek
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.8
    • /
    • pp.464-471
    • /
    • 2008
  • The electrolyte separator for thermal battery should be easily handled and loaded a large amount of the molten salt. Ceramic fibers, especially fibrous commercial glass filters were used as an electrolyte separator and the lithium based molten salts were infiltrated into the ceramic filters. The pore structures of the ceramic filter and the melting properties of the lithium salts affected to the electrolyte loading and leakage. During the infiltration, ions of $Li^+$ and $F^-$ in the molten salts were reacted with the glass fiber and caused to be weaken the fiber strength.

Development of the Air Floating Conveyor System for the Large Glass Sheet (대평판 글라스 이송용 공기 부상 이송장치의 개발)

  • Lee, Tae Geol;Yu, Jin Sik;Jung, Hyo Jae;Kim, Jong-Hyeong;Kim, Joon Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.635-642
    • /
    • 2013
  • We have prepared a DEMO conveyor device for conveying a large 8G class glass sheet using ahorizontal air-cushion system. This device consists of the body frame and the driving frame that are combined to realize a frame for conveying glass without any contact.The driving frame comprises an air flotation table (bed), drive roller supported at both ends, and ASU. Part of the ASU serves to control the airflow as the chamber consists of a porous pad and fan. Fiber filters replace the porous pad and axial fans serve as an air compressor. In addition, to determine the appropriate glass levitation from the air table, this study examined the design specifications of the applied filter (discharge speed of HEPA and ULPA filters, and flow rate) as well as the height of the and the proper supporting roller height (14mm). Then, after adjusting the position of the ASU and the number of ASUs required to configure the UNIT air floating C/V, we analyzed the height and flatness of the glass and derived the appropriate layout (1140-mm distance between ASUs).

Study on the Filter Collection Methods of Ammonia and Ammonium Salts in the Atomosphere (대기중의 암모니아 및 암모늄염의 필터포집법에 관한 연구)

  • Hui Kang Kim;橋本芳一;Yong Keun Lee
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.36-42
    • /
    • 1982
  • Filters were evaluated to use in the collection of ammonia and ammonium salts in the atmosphere. Ammonia from standard gas generator was collected on a glass fiber filter impregnated with a mixture of 3% boric acid and 25% glycerin. The collection efficiency by the impregnated filter was 96.4${\pm}$2.15% in pH control method and 97.4${\pm}$1.06% in the atmosphere for five measurements, respectively. Adsorption and desorption of gaseous ammonia were compared using three commercially available filters; glass fiber, quartz fiber and polycarbonate filters. Both glass and quartz fiber filters indicated some loss of ammonium salts and adsorption of ammonia, respectively. However, polycarbonate filter was found to be satisfactory for the collection of ammonium salts in the atmosphere. The minimum measurable concentration of ammonia was 0.83ppb (ca. 0.63${\mu}g$/$m^3$) by spectrophotometry of the indophenol method for the sample collected by 47mm${\phi}$ filter(20l/min, 60min). The sensitivity of the present method is about 20 folds higher than that of conventional method of bubbler collection followed by spectrophotometry, so that this method makes it possible to measure thevariation of ammoniacal concentrations in the atmosphere for a short time period of about 60 min.

  • PDF

A Study on the Positively Charged Filter for Removing Fine Particles in Water (양전하가 부가된 수처리 필터의 입자제거특성에 관한 연구)

  • Jung, Sung-Hak;Kim, Jong-Won;Kim, Sang-Hee;Jeon, Byung-Heon;Lee, Seung-Gap;Lee, Jae-Keun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.454-460
    • /
    • 2012
  • The purpose of the present work is to investigate the removal characteristics of positively charged filters for capturing negatively charged particles such as bacteria and virus in water. In order to reduce the pressure drop and increase the filtration efficiency, the filter media, modified by charge modifier having positive functional groups, is developed and evaluated. Improved liquid filters have been developed with the modified surface charge to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in an aqueous liquid. The positively charged filter media is composed of glass fiber, cellulose and poly-ethylenimine resin for positively charging with the variation of volume ratio. The zeta potential value of the positively charged filter is +37.92 mV at the glass fiber and cellulose content ratio of 50 : 50 with resin content of 100%, while that of the PSL test particle is -23.5 mV at pH 7. The removal efficiency of the electro-positively charged filter is 98% for PSL particles of 0.11 ${\mu}m$, while that of the negatively charged filter is 7%. The positively charged filter media showed the potential to be an effective method for removing fine particles from the contaminated water for liquid filtration.

Improvment on the filtration process of foxtail millet Yakju (좁쌀약주의 여과공정 개선에 관한 연구)

  • 강영주;고정삼
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.482-487
    • /
    • 2003
  • The filtration effects of glass membrane filters and hollow fiber membranes with different pore size to prevent the haze of a commercial foxtail millet Yakju were investigated. The most particles(haze precusors) present in the Yakju were removed by using 1.2 $\mu\textrm{m}$ glass membrane filter. In case of using 0.45$\mu\textrm{m}$ hollow fiber membrane system, the permeate flux on the Yakju filtration was calculated to 342.8 lmh. During the 3 month storage at 4$^{\circ}C$ and room temperature for each 48 hrs in turn, alittle fine haze was observed from the Yakju even if it was filtered by using 0.7 $\mu\textrm{m}$ glass membrane filter. Anything of haze was, however, observed from the Yakju filtered by using all of hollow fiber membranes. Therefore, the 0.45$\mu\textrm{m}$ hollow fiber membrane system was effective as a final filtration process of the Yakju.

Novel Flexible Supercapacitors Fabricated by Simple Integration of Electrodes, Binders, and Electrolytes into Glass Fibre Separators

  • Yoo, Joung Eun;Bae, Joonho
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.4
    • /
    • pp.237-244
    • /
    • 2014
  • We report novel and simple structure of supercapacitors fabricated by using flexible glass fibre separators as templates. This method does not require separate electrodes, binders and high pressure/temperature to build the supercapacitor unit cells as required by the conventional technology. The supercapacitors were fabricated by drop-casting solution mixtures of carbonaceous active materials/gel electrolytes onto two sides of glass fibre separators. Two carbonaceous materials (nanoscaled activated carbons, multi-walled carbon nanotubes) were investigated as electrode materials. The electrochemical measurements reveal that the separatorbased supercapacitors using ACs successfully demonstrated significant mass specific capacitance ($22.3F\;g^{-1}$) and energy density ($9.7Wh\;kg^{-1}$), indicating this method can be useful in fabricating flexible, wearable and stretchable energy storage devices in more straightforward and cost-effective way than current technology.

A Study on Polynuclear Aromatic Hydrocarbons Emitted by Coking Time and Sampling Method in a Coke Oven Plant (코크스제조공정에서 탄화시간과 시료채취방법에 따른 다핵방향족탄화수소 발생에 관한 연구)

  • Yun, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.37-53
    • /
    • 1993
  • The polynuclear hydrocarbons (PAHs) emitted from coke oven standpipe were sampled using three sampling systems, including glass fiber filter+silver membrane filter, glass fiber filter+silver membrane filter+XAD-2 adsorbent tube, PTFE membrane filter+XAD-2 adsorbent tube, extracted by methylene chloride and analysed by gas chromathography using flame ionization detector. The results of this study were as follows. 1. Because the amounts of coke oven emissions(COE) were large, the analyses of PAHs were simple and possible without evaporation and concentration. Although the generation of COE was high during early stage of coking, the airborne concentration of PAHs was low and increased during late coking. 2. The contents of PAHs in COE were 1.35-2.81%. 3. The index components of PAHs were fluoranthene and pyrene. Their correlation coefficient to total PAHs were 0.96, 0.95, respectively. 4. The particulate PAHs were sampled by filter and gaseous PAHs by adsorbent tube. The collection efficiency of glass fiber filter+silver membrane filter was 20% of total amount sampled by filters+adsorbent and PTFE membrane filter 50%. Adsorbent tube must be attached to the filter to collect light and small PAH components. 5. The generation of acenaphthene and indeno (1,2,3-cd) pyrene were low and concentrations of fluorene and anthracene were $20-40ug/m^3$ throughout coking time. Other PAH eoncentrations were sometimes high. The generation of PAHs was low at 4-6 hours of coking time. The gaseous PAHs were generated earlier than particulate PAHs.

  • PDF