• 제목/요약/키워드: geothermal technology

검색결과 223건 처리시간 0.026초

건물일체형 지열시스템의 동계 성능 모니터링 연구 (Performance Monitoring Study of Building Integrated Geothermal System in Winter)

  • 유형규;배상환
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.23-28
    • /
    • 2010
  • The objective of this study is to develope ground heat exchanger using PHC pile used to building foundation, and it's element technology. So we made PHC piles into ground heat exchanger and evaluate it's performance. First, we studied PHC pile type, heat exchanger pipe, grouting materials, and present apartment house's foundation condition for PHC ground heat exchanger. As a result we designed BIGS(Building Integrated Geothermal System) prototype. Second, we applied BIGS to apartment houses' utility building in Osan built by Daelim. Third, we monitored heating performance of winter season. 1be result of heating performance was so good to apply to heat & cooling system in building.

EGS 지열발전과 저류층 수리자극 기술 (EGS Power Generation and Hydraulic Stimulation)

  • 민기복;송윤호;윤운상
    • 터널과지하공간
    • /
    • 제23권6호
    • /
    • pp.506-520
    • /
    • 2013
  • 지열에너지는 기저부하를 제공하는 신재생에너지이나 현재까지 화산지대에만 대부분의 지열발전이 이루어져 왔다. 인공저류층 지열시스템 (Enhanced Geothermal System, EGS)는 비화산지대의 지열발전을 가능하게 할 개념으로 알려져 있으며 수리자극(hydraulic stimulation)이 핵심기술이다. 본 논문은 EGS지열발전의 개발 현황을 소개하고, 수압파쇄와 수리전단이 주 메커니즘인 수리자극의 핵심원리, 설계변수 및 수리자극에 수반되어 발생하는 미소진동의 원리 및 관측기술을 소개한다. 한국에서의 EGS 지열발전을 위하여 필요한 과제를 소개하여 향후 기술개발의 방향을 제시한다.

지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가 (Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System)

  • 박시삼;나상민;박종헌;이건중;김태원;김승엽
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

국내의 지열에너지 열펌프 시스템 활용현황과 활성화 방안 (Application and Revitalization Method of Domestic Geothermal Heat Pump System)

  • 박혜리;고영호;김민태;박종일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.922-927
    • /
    • 2009
  • Due to the law of use of sustainable alternative energy recently legislated, many public institutions are ordered to use renewable energy. So it gets people's eyes on Geothermal energy system among other suggested renewable energy. Since there is hardly existence of a volcanic region, Geothermal heat pump system is generally used most in Korea. However, the important technology and materials are not localized and further, with only our technical skills it is arduous to popularize and develop Geothermal energy because of lack of revitalization related to the law and the regime for locally suitable Data-base. Moreover, an access of renewable energy is too much hard because of people's low interests about Geothermal energy. But fortunately, the well-studied about Geothermal heat system started to be adopted in many other provinces. Therefore, we study this with intend to popularize and develop Geothermal energy.

  • PDF

동특성 시뮬레이션을 이용한 공기, 지열 및 지하 저수조 열원 소형 열펌프의 경제성 분석 (Economical Analysis of a Small Capacity Heat Pump utilizing Heat Sources of Air, Geothermal and Underground Water Tank using Dynamic Simulation)

  • 양철호;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 2012
  • Due to reinforcement of international environment regulation and high oil prices, interest in renewable energy is growing. Countries participating in UNFCCC are continuously putting efforts in reducing greenhouse gas after enforcing Kyoto Protocol into effect on Feb, 2005. Energy used in buildings, which relies heavily on fossil fuel accounts for about 24% of total energy consumption. In this study, air, geothermal and water source heat pump systems for an 322 $m^2$ auditorium in an office building is simulated using TRNSYS version 17 for comparing energy consumptions. The results show that energy consumptions of air, geothermal and water source heat pumps are 14,485, 10,249, and 10,405 kWh, respectively. Annual equal payments which consider both initial and running costs become 5,734,521, 6,403,257 and 5,596,058 Won. Thus, water source heat pump is the best economical choice.

주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가 (Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building)

  • 김용식;김중헌;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석 (Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells)

  • 조정흠;남유진
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

복합열원 히트펌프 최적 제어를 위한 열원에 따른 히트펌프 성능 및 에너지 소요량 패턴 비교 (Comparison of Heat Pump Performance and Energy Consumption Patterns according to Heat Sources for Optimal Control of Multi-Source Heat Pumps)

  • 고유진;박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.31-38
    • /
    • 2020
  • The investment in the technology of using a combined heat source is insufficient, which utilizes the advantages of various heat sources to maximize the potential energy and at the same time increases the performance of the heat pump. In this study, as basic data for the development of a high-efficiency hybrid heat pump system that actively connects and uses various heat sources, simulations were conducted for the heat pumps in two cases where geothermal and hydrothermal heat were applied respectively. In May, COP increased by about 27.3% compared to geothermal heat. In February, the COP percentage decrease of hydrothermal heat compared to geothermal heat is -6.9%. In May, total energy consumption can be reduced by 21.1% when hydrothermal is applied compared to geothermal heat. In February, the total energy consumption increases by 3.4%.

여과수열원 히트펌프를 이용한 온실난방기술 개발 (Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;강연구;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

고심도 지중열전도도에 의한 지열 응용의 효율성 (Efficiency of Geothermal Energy Generation Assessed from Measurements of Deep Depth Geothermal Conductivity)

  • 조희남;이달희;정교철
    • 지질공학
    • /
    • 제22권2호
    • /
    • pp.233-241
    • /
    • 2012
  • 이 연구의 목적은 현장의 지중열교환기에서 조건별 지중열전도도, 유속, 유량 및 파이프관내 압력을 측정하고, 이들 시험자료들을 분석하여 지열응용의 효율성을 평가하는데 있다. 규정에 따라 현장측정 장비를 설치한 후 3가지 다른 경우에서 각각 열전도도를 얻었다. 2차와 3차 경우의 결과를 바탕으로, 동일한 암반 지중하에서 다른 깊이(506 m, 151 m), 다른 파이프관경(65 mm, 30 mm)별 얻어진 열전도도는 각각 k=2.9, k=2.8로 크게 차이가 나지 않았다. 4차 경우는 2차 경우와 같은 조건의 심도 지중하에서도 이중관일 경우에는 열전도도가 k=2.5로 크게 차이 나지 않았다. 이러한 결과는 지열이용 시, 같은 지질일 경우 깊이가 중요한 변수가 될 수 있음을 보여 주고 있다. 또한 이 시험에서 얻은 물의 유속과 물의 유량 측정값 및 열전도도를 시뮬레이션 분석한 결과, 지열시스템의 운영 시 심도 506 m 지열공 한개가 심도 151 m 지열공 3개 운영보다 더 경제적임이 확인되었다. 비슷한 지중열전도도 환경에서 0.8 m/sec로 같은 유속일 경우 약 4배의 유량($9.3{\sim}9.8m^3/d$, $2.3{\sim}2.5m^3/d$)의 차이를 보였다. 특히 대도시 건물 밀집형 지대 또는 지가가 비싸서 간접비가 많이 발생하는 대도시 지역에서는 훨씬 더 경제적일 것으로 판단된다.