• Title/Summary/Keyword: geothermal heat pump systems

Search Result 110, Processing Time 0.025 seconds

Study on the Performance of a Cascade Heat Pump with Two-stage Water Heating Process (2단 승온 캐스케이드 히트펌프의 성능 특성에 관한 연구)

  • Jang, Hanbyeoul;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.27-32
    • /
    • 2016
  • It is estimated that only heating and cooling take about one third of the total energy consumption worldwide. However, the conventional heating and cooling systems have low efficiencies. Also, boilers and electric heaters that are mostly used to generate both domestic and industrial hot water are inefficient and high energy consumers. For this reason, cascade heat pumps which are known to be very energy efficient and have less environmental impact are being promoted to replace conventional heating, cooling and hot water systems. In this study, a newly designed cascade heat pump by two-stage water heating method has been experimentally investigated. By adopting the auxiliary heat exchanger, the performance of the system was increased. The performance enhancement rate of the system could be maximized by adjusting the low stage compressor speed rather than the high stage compressor speed. The performance of the system with the auxiliary heat exchanger was enhanced by 16.5%.

A Study on Comparative Analysis of Energy Performance of Hybrid Heat Pump Systems Using Ground Heat Source and Water Heat Source (지열원과 수열원을 이용한 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 연구)

  • Park, Sihun;Kim, Jonghyun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.59-67
    • /
    • 2021
  • In this study, the performance of the single heat source system and the hybrid system was comparatively analyzed. Case 1 is a ground heat source system, and Case 2 is a water heat source system. Case 3, a hybrid system, reduced the capacity of the ground heat source and applied a water heat source as an auxiliary heat source, and Case 4 was composed of a system that applied a water heat source as an auxiliary heat source to the ground heat source system. As a result of the simulation, in case 3, energy consumption was reduced by up to 2.67% compared to ground sources for cooling. In Case 4, COP was improved by up to 10.02% compared to ground sources during cooling, and EST was calculated to be 2.42℃ lower. During heating, 0.83% was improved compared to the water heat source. At this time, the EST was calculated to be 2.25℃ higher than the water heat source.

The development of a ground source heat pump using R410A (R410A 대체냉매 적용 지열히트펌프 개발)

  • Kim, Ji-Dong;Chung, Bong-Chul;Jeong, Il-Kwon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 2007
  • The growth of domestic energy demand is rapidly increased for the industrialization and the improvement of the living standards. It is also recognised that the importance of the use of environmentally friendly energy and high efficient equipment. Ground Source heat pumps (GSHP) using earth as heat source or sink are outstanding environmentally friendly energy systems which have high thermal efficiency when compared to conventional heating and cooling system. So government employs a policy and increase investment for expanding renewable energy market volume. Especially is established a system for obligatory usage of renewable energy to achieve 5% renewable energy diffusion rate by 2011. And the market demand for the ground source heat pump is rapidly growing due to its strong advantages. However domestic situation usually have been depended on the import of ground source heat pumps. In this paper, the results of development of a ground source heat pump using refrigerant R410A are reported.

  • PDF

A Study on the Application Plan of Air-Conditioning and Renewable Complex Systems in the Small Schools. (소규모 학교의 냉난방 및 신재생에너지복합시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Hong, Sung-Hee;Kim, Seong-Sil;Hur, Inn-Ku;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.946-951
    • /
    • 2009
  • The research aims to study a new, optimum and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and water heating energy saving efficiencies for educational facilities. Therefore, this research carried out a study on the new/renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 174kW + solar heat collector $94\;m^2$ + highly efficient electronic cooling/heating device (EHP) 249.4kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 255.2kW + highly efficient electronic cooling/heating device (EHP) 168.2kW.

  • PDF

A Study on the Application Plan of Air-Conditioning and New and Renewable Systems in the Large High Schools (대규모 고등학교의 냉난방 및 신재생에너지시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Kim, Seong-Sil;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.564-574
    • /
    • 2009
  • The study is conducted to study a new, optimum and new and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and hot water supply energy saving efficiencies for educational facilities. Therefore, this research implemented a study on the new and renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 475.6 kW+highly efficient electronic cooling/heating device(EHP) 545.2 kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 261kW+solar heat collector $240\;m^2$+highly efficient electronic cooling/heating device(EHP) 759.8 kW.

A Study on Development of a Ground-Source Heat Pump System Utilizing Cast-in-place Concrete Pile Foundation of a Building (현장타설형 건물 기초를 이용한 지중열 공조시스템의 성능평가에 관한 연구)

  • Hwang, Suck-Ho;Nam, Yu-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.641-647
    • /
    • 2010
  • Ground-source(Geothermal) heat pump(GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump(ASHP) systems. However, GSHP systems are not widespread because of their expensive installation costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a full-scale experiment. As a result, the average values for heat rejection were 186~201 W/m(per pile, 25 W/m per pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems.

Evaluation of Ground Effective Thermal Properties and Effect of Borehole Thermal Resistance on Performance of Ground Heat Exchanger (지중 유효 열물성 산정 및 지중열교환기 성능에 대한 보어홀 열저항의 영향)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.32-40
    • /
    • 2012
  • Geothermal heat pump(GHP) systems use vertical borehole heat exchangers to transfer heat to and from the surrounding ground via a heat carrier fluid that circulates between the borehole and the heat pump. An Important feature associated with design parameters and system performance is the local thermal resistances between the heat carrier flow channels in the borehole and the surrounding ground. This paper deals with the in-situ experimental determination of the effective thermal properties of the ground. The recorded thermal responses together with the line-source theory are used to determine the thermal conductivity and thermal diffusivity, and the steady-state borehole thermal resistance. In addition, this paper compares the experimental borehole resistance with the results from the different empirical and theoretical relations to evaluate this resistance. Further, the performance simulation of a GHP system with vertical borehole heat exchangers was conducted to analyze the effect of the borehole thermal resistance on the system performance.

Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System (지열-열펌프 시스템의 온실냉방 및 육묘 효과)

  • Lee, Jae-Han;Lee, Yong-Beom;Kwon, Joon-Kook;Kang, Nam-Jun;Kim, Hak-Joo;Choi, Young-Hah;Park, Jin-Myeon;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.211-216
    • /
    • 2006
  • This study was carried out to investigate the effect of greenhouse cooling by a geothermal heat pump system on greenhouse temperature and growth of vegetable transplants in summer season. Greenhouse air temperature in day time was $3-4^{\circ}C$ lower in fog plus shading system than in shading, while in night time that was $5-7^{\circ}C$ lower in geothermal heat pump (GHP) plus shading system compared to shading or fogplus shading. system. Plant height of cucumber, tomato and hot pepper transplants was shortened in GHP plus shading compared to shading or fog plus shading system. And Leaf area and dry weight were slightly decreased in GHP plus shading compared to the other systems. Therefore, healthy transplant index on cucumber, tomato and hot pepper was higher in GHP plusshading than in shading or fogplusshading system.

A study on economic evaluation when renewable energy system is introduced in public buildings inside of Daegu Sin-seo innovation city (대구신서혁신도시 내 공공건축물의 신재생에너지 시스템 도입시 경제성 평가에 관한 연구)

  • Kim, Bo-Ra;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.175-180
    • /
    • 2009
  • According to an increasing demand of political support and development on renewable energy as a solution for the energy problem in Korea, the government has established a goal to raise renewable energy supply from 2.27% to 5% until 2011. Especially in the case of public building in which energy use is in great demand, it would bring a great advantage to develop and utilize the Photovoltaic System as an electric energy and Geothermal Heat Pump System as a thermal energy. On the occasion of Photovoltaic System, Photovoltaic module can be used as an architectural material so that it can reduce construction cost and when we use solar energy, it is possible to make building's own power supply. As for Geothermal Heat Pump System, It can be used infinitely as long as the solar energy exist and operation cost is cheap and yearly efficiency is stable. However, we need to make a plan to reduce early investment expanses for these two renewable energy systems and to expand a diffusion rate as we develop a competitive domestic technology level. So in this study, we are going to perform evaluation of economical efficiency according to the introduction of Photovoltaic System and Geothermal Heat Pump System in public buildings which will be built up inside of Daegu Sin-seo innovation city. As a first step, we will investigate present installation condition of these two renewable energy systems and based upon that, will seek efficient introduction program of renewal energy systems that can be applied in public buildings.

  • PDF

Investigation and Analysis on the present state of Geothermal Source Heat Pump System Applied in Korea (지열히트펌프 시스템의 국내 적용현황 조사 및 분석)

  • Choi, Mi-Young;Ko, Myeong-Jin;Kim, Yong-Shik;Park, Jin-Chul;Rhee, Eon-Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.267-272
    • /
    • 2009
  • This study aims to investigate and analyze the present state of ground source heat pump(GSHP) system applied in Korea. It is based on the statistic from the New and Renewable Energy Center in Korea and construction results of the professional companies registered to the center. The research items were installed area, installed year, building use, ground heat exchange type and heat exchanger type of the pump. According to the result of investigation, the using GSHP system have been increasing steadily as the space heating and cooling system in a building. The capacity of this system is also becoming lager based on technical and economical feasibility analysis about the system since GSHP system first introduced in 2000.