• 제목/요약/키워드: geothermal conductivity

검색결과 111건 처리시간 0.027초

TOUGH2를 이용한 폐쇄형 지열펌프 시스템의 3차원 모델링 연구 (3 Dimensional Numerical Simulation for the Closed Loop Heat Pump System Using TOUGH2)

  • 김성균;배광옥;이강근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.36-39
    • /
    • 2006
  • To evaluate the effect of groundwater flow on the outlet temperature of a geothermal heat pump, 3 dimensional numerical simulations are performed considering both groundwater flow and pipe flow in the U-tube using TOUGHS, The present study involved the following 4 simulation cases (1) no groundwater flow, (2) slow groundwater flow (hydraulic conductivity: $1.0{\times}10^{-9}m/s)$, (3) fast groundwater flow (hydraulic conductivity, $1.0{\times}10^{-7}m/s$), and (4) groundwater flow varying with the depth (hydraulic conductivity: $1.0{\times}10^{-7}-1.0{\times}10^{-10}m/s$). The effect of groundwater flow on the outlet temperature is significant where hydraulic conductivity of aquifer is $1.0{\times}10^{-7}m/s$. Where hydraulic conductivity of aquifer is $1.0{\times}10^{-10}m/s$, however, that effect is negligible.

  • PDF

현지 측정에 의한 남한지역의 지중유효열전도도, 보어홀 전열저항 및 초기온도 분석 (Analysis of Soil Thermal Conductivities, Borehole Thermal Resistances and Initial Soil Temperature with In-Situ Testing in South Korea)

  • 노정근;연광석;송헌
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.68-74
    • /
    • 2012
  • Investigation of the effective soil thermal conductivity($k$) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. The first step is measured for initial soil temperature. This is done by supplying a only pump power into a borehole heat exchanger. They need to supply into water unload heat power more than 30 minutes. In this study, the initial soil temperature was found to analysis $14.1{\sim}16.0^{\circ}C$,the ratio was 68.7% represented. In this case of $k$, was 2.1~3.0 $W/m{\cdot}k$, $R_b$ was 0.11~0.20 $m{\cdot}K/W$. In this work, it is also shown that the distribution of a soil thermal conductivity and borehole thermal resistance were on the influence of initial soil temperature. And soil thermal conductivity was related with factors of equation by linear least square method, borehole thermal resistance was on the influence of composite factors.

상온 환경에서 PEDB를 이용한 울릉도 시추코어의 열전도도 예비 측정 (Thermal Conductivity Measurement of Rock Cores from Ulleung Island Using PEDB System at Room Temperature)

  • 이상규;이태종
    • 지구물리와물리탐사
    • /
    • 제19권3호
    • /
    • pp.121-130
    • /
    • 2016
  • 다양한 지름의 암석코어에 대해 비교적 간편하고 정확하게 열전도도를 측정할 수 있는 divided bar형 열전도도 측정 시스템인 PEDB (potable electronic divided bar system)를 도입 이용하여 열전도도 측정시 고려해야 할 요소에 대해 검토하였다. 또한, 지열조사를 위해 울릉도에서 채취한 70개의 코어시료에 대해 적용하고 그 특성을 살펴보았다. 열전도도 측정에 있어서 실내온도의 변화가 가장 큰 영향을 미치므로 되도록 실내온도의 변화가 적거나 항온 환경에서 측정하는 것이 바람직하다. 열원(heat source)의 온도, 안정된 상태에서 평균하는 온도의 구간 등에 의한 영향은 실내온도 변화에 비해 미미하다. 열접촉 보조제인 바셀린을 사용하면 시편의 열전도도가 다소 높게 평가되고 특히 접촉면이 고르지 않은 암석시편에서는 그 차이가 더 크게 나타난다. 하나의 시편에 대해 반복 측정할 때, 실내온도가 $1^{\circ}C$ 이내로 유지된다면 표준시편에서는 ${\pm}0.3%$ 이내, 암석시편에서는 ${\pm}4%$ 이내의 좋은 반복성을 얻을 수 있다. 울릉도의 두 지열 조사공에서 얻은 암석코어의 열전도도는 심도 증가에 따라서 대체로 열전도도가 커지는 경향이 있으나 암종 변화와 특별한 상관성을 보이지는 않았다.

지중 열교환기의 보어홀 열저항 산정에 관한 연구 (Evaluation of Borehole Thermal Resistance in Ground Heat Exchanger)

  • 윤석;이승래;강한별;고규현;김민준;신호성
    • 한국지반공학회논문집
    • /
    • 제29권10호
    • /
    • pp.49-56
    • /
    • 2013
  • 최근 들어 경제적이고 친환경적인 에너지 활용을 위하여 지열에너지 필요성이 증대되고 있다. 지반의 열전도도(ground thermal conductivity)와 보어홀 열저항(borehole thermal resistance)은 지열 히트펌프 시스템(geothermal heat pump system)의 설계 과정에서 매우 중요한 변수이다. 본 논문에서는 일반 수직밀폐형에서의 U, W 타입의 지중 열교환기(ground heat exchanger)를 매립지 지반에 설치한 후 100시간 연속 운전 조건으로 현장 열성능 실험(thermal performance test)을 수행하였다. 또한 보어홀 열저항 산정 모델들을 이용하여 열효율을 산정한 후 이를 실험값과 비교하였다. 실험 결과 기존에 주로 적용되고 있는 shape factor(SF) 모델보다 multi-pole과 equivalent diameter(EQD) 모델이 계측값과 잘 일치하였다.

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity)

  • 공형진;임효재;최재호;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

수직 밀폐형 지중 열교환기용 뒤채움재로서 흑연(Graphite)을 첨가한 벤토나이트 그라우트재의 물리적 특성연구 (Study on physical characteristics of Graphite-added bentonite grout for backfilling closed-loop groud heat exchanger)

  • 이강자;길후정;이철호;최항석;최효범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.179-187
    • /
    • 2009
  • Bentonite-based grouting has been popularly used to seal a borehole installed for a closed-loop vertical ground heat exchanger in a geothermal heat pump system (GHP) because of its high swelling potential and low hydraulic conductivity. The bentonite-based grout, however, has relatively lower thermal conductivity than that of ground formation. Accordingly, it is common to add some additives such as silica sand to the bentonite-based grout for enhancing thermal performance. In this study, graphite is adapted to substitute silica sand as an addictive because graphite has very high thermal conductivity. The effect of graphite on the thermal conductivity of bentonite-based grouts has been quantitatively evaluated for seven bentonite grouts from different product sources. In addition, comparisons of viscosity between applications of graphite and silica sand as additives has been carried out. In conclusion, using graphite has thermal conductivity about three times higher than that of silica sand.

  • PDF

포항 심부 지열 시추공에 대한 물리검층 자료해석 (Interpretation of Geophysical Well Logs from Deep Geothermal Borehole in Pohang)

  • 황세호;박인화;송윤호
    • 지구물리와물리탐사
    • /
    • 제10권4호
    • /
    • pp.332-344
    • /
    • 2007
  • 경북 포항 부근에서 지열에너지 개발을 위하여 굴착된 심부 시추공에서 다양한 물리검층을 수행하였다. 물리검층의 주요 목적은 지층층서 해석, 원위치 물성 평가, 대수층 추정 등이다. 물리검층 자료 중에서 자연감마선검층 자료를 시추공 BH-1호공의 코어검층과 비교하여 제3기 반고결 퇴적층 및 백악기 퇴적층과 관입암 등의 지층 층서를 해석하였다. 원위치 지층 물성 대비도표는, 제3기 퇴적층, 백악기 퇴적층과 관입암 등의 지질 구분에 효과적으로 이용되었다. 시추공 BH-4호공의 심도 1981.3 m에서의 온도는 $82.51^{\circ}C$로 측정되었으나 안정된 상태에서 측정한 시추공 BH-2호공의 온도가 시추직후 교란된 상태에서 측정된 온도보다 높았음을 고려할 때, 실제 온도는 이보다 $5{\sim}6^{\circ}C$ 정도 높을 것으로 예상된다. 온도/전기전도도 변화율검층, 암편로그에서 대수층으로 추정되는 구간이 다수 존재하는 것으로 해석되었다.

TPS를 통한 열물성치 획득 및 네트워크모델을 이용한 열해석 (Measurement of thermal properties by TPS-technique and thermal network analysis)

  • 윤태섭;김영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.263-268
    • /
    • 2010
  • Thermal characterization of geomaterials has significant implication on the geothermal energy, disposal of nuclear wastes, geological sequestration of carbon dioxides and recovery of hydrocarbon resources. Heat transfer in multiphase materials is dominated by the thermal conductivity of consisting components, porosity, degree of saturation and overburden pressure, which have been investigated by the empirical correlation at macro-scale. The thermal measurement by Transient Plane Source (TPS) and associated algorithm for interpretation of thermal behavior in geomaterials corroborate the robustness of sensing techniques. The method simultaneously provides thermal conductivity, diffusivity and volumetric heat capacity. The newly introduced thermal network model enables estimating thermal conductivity of geomaterials subjected to the effective stress, which has not been evaluated using previous thermal models. The proposed methods shows the applicability of reliability of TPS technique and thermal network model.

  • PDF

초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향 (Effect of initial ground temperature measurement on the design of borehole heat exchanger)

  • 송윤호;김성균;이강근;이태종
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

열응답 실험 해석 및 국내 현황 (Thermal Response Test (TRT) interpretation and the status in Korea)

  • 심병완;최충현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.168.2-168.2
    • /
    • 2010
  • The growing market for geothermal heat pump system requires great consideration of quality control and assurance in design and construction. The borehole heat exchanger of GHP system should be sustainable, economical and ecological. Thermal Response Test (TRT) is a useful method for site investigation to obtain reliable data for a optimal system design from the technical and economical aspect. Intensive researches combined with exchange of experiences on an international level within the IEA ECES Annex 21 improved the technology. Major subjects on the interpretation of TRT are development of improved evaluation models, evaluation of the TRT with respect to geological layers and investigation of the influence of ground water. Current status of TRT in South Korea, as well as a new version of the Korean TRT standard test procedure was presented. TRT is mostly used for governmental supported projects with corresponds to more than 100 GCHP systems per year. More than 200 tests are applied, mostly on single U-tube heat exchangers (about 95%). Bentonite is the most common grouting to be used. KIGAM (Korea Institute of Geoscience & Mineral Resources) is also keeping a GIS geological and geothermal database. In the institute also laboratory measurements of rock properties are carried out. About 90% of the laboratory measurements of the rock heat conductivity shows higher values than the in-situ TRT.

  • PDF