• Title/Summary/Keyword: geotechnical monitoring

Search Result 365, Processing Time 0.021 seconds

Development of GIS Based Risk Assessment System for Adjacent Structures Due to Tunnelling-Induced Ground Movements in Urban (GIS기반을 이응한 도심지 터널굴착에 따른 인접 구조물 손상평가 시스템 개발)

  • 윤효석;박용원;오영석;김제규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.493-500
    • /
    • 2001
  • The construction of bored tunnels in soft ground inevitably causes ground movements. In the urban environment these may be of particular significance, because of their influence on buildings, other tunnels and services. The prediction of ground movements and the assessment of the potential effects on the structures is therefore an essential aspect of planning, design and construction of a tunnelling project in the urban environment. In this study, to minimize the effect of tunnelling-Induced ground movements on the adjacent structures, a system for tile settlement risk management was developed. The GIS based risk assessment system for adjacent structures developed in this study consists of several modules such as building information module, settlement evaluation module, potential risk assessment module for adjacent structures, and analysis module for monitoring data. This system focuses on controlling and managing construction processes that may lead to settlement In the surrounding buildings and can contribute to producing the optimum technical and economic design.

  • PDF

A Study of a Levee Failure Forecasting using SAM Algorithm (SAM 알고리즘을 이용한 하천제방 붕괴예측에 관한 연구)

  • Yoo, Byung-Sun;Park, Yong-Dae;Lee, Kyu-Shik;Chang, Ki-Tae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.649-658
    • /
    • 2009
  • The Aim of this development is the safety management network of embankment facilities using forecasting analysis algorism. Using this algorithm it is possible to predict a failure of embankment facilities in advance. therefore, it is necessary for making plans of a safety countermove. In this development we have researched the analysis method which could operate effectively the embankment facilities using real-time monitoring data from a remote sensing system and the safety managerial program using the algorithm from the analysis method developed.

  • PDF

Characteristics of Abutment Slopes of Four Dams in Korea (우리나라 주요 댐 좌우안 사면의 특징)

  • 신동훈;이종욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.183-195
    • /
    • 2000
  • Slopes near a dam body can be categorized into 4 groups, such as right and left abutment slopes, reservoir slopes, slopes along the access road and slopes along the relocated road. For each of the geological investigation, the design standards, the evaluation methods of safety and the maintenance methods, both abutment slopes in the four dams have different characteristics from the conventional cut slopes in that they can severely affect the dam safety. From this point of view this study compares and analyzes the geological investigation methods, the status of design and construction, evaluation method of safety, and monitoring & maintaining methods for four major dams in Korea, such as Soyanggang dam, 'Andong dam, Chungju dam and Boryong dam.

  • PDF

Application of Brillouin Scattering Sensor for Broader Area Slope Movement (광 산란파를 이용한 광역 사면 거동 예측)

  • 장기태;이쌍덕;유병선;김경태;정성윤;이원효
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.223-232
    • /
    • 2000
  • Optical fibre sensors have shown a potential to serve real time health monitoring of the structures. They can be easily embedded or attached to the structures and are not affected by the electro-magnetic field. Furthermore, they have the flexibility of the sensor size and very highly sensitive. In this study, we conducted several laboratory and field tests using a novel optical sensor based on Brillouin scattering. One of the advantages of this technique is that the bare fibre itself acts as sensing element without any special fibre processing or preparation. Test results have shown that BOTDR can be a great solution for sensor systems of Civil Engineering Smart Structures.

  • PDF

Tension Monitoring of Prototype Smart Anchor for Geotechnical Disaster Prevention (지반방재용 스마트 앵커의 장력측정 및 하중전이 측정)

  • Kim, Young-Sang;Sung, Hyun-Jong;Kim, Jae-Min
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.90.2-90.2
    • /
    • 2010
  • 흙막이 굴착 및 절취사면의 보강공법으로 많이 적용되고 있는 앵커의 장력을 측정하는 전기저항식 로드셀과 스트레인게이지, 바이브레이팅 와이어 (vibrating wire) 타입의 모니터링 방법은 안전관리를 위한 장기적인 모니터링에 한계를 가지고 있어 이를 개선할 수 있는 방안으로 광섬유 센서를 이용하여 강연선의 변형률을 측정할 수 있는 스마트 텐던이 개발되었다(김재민 등, 2007). 앵커를 구성하는 7연 강연선(텐던)의 중앙케이블에 삽입된 광섬유브래그격자(Fiber Bragg Grating ; FBG)센서는 기존 스트레인게이지 타입에 비해 크기가 작고 내구성이 우수하며 전자기파에 의한 노이즈 발생이 없고 하나의 리드선으로 다중점 측정(multiplexing)이 가능하여 장기모니터링에 효과적인 장점이 있다. 본 연구에서는 FBG센서를 내장한 스마트 텐던을 실대형(Prototype) 앵커(L=11.5m)에 적용하여 현장 인발실험에 의해 시공중 장력 모니터링을 수행하고 로드셀 측정결과와 비교하였고 정착부에 설치된 FBG 센서로부터 앵커의 하중전이 계측을 수행하였다.

  • PDF

A case study on the evaluation of pile damage during driving by PDA testing. (PDA 시험을 이용한 말뚝손상 판단에 관한 사례 연구)

  • 송명준;박영호;이영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.334-341
    • /
    • 2002
  • Nowadays, owing to the development of analysis techniques for PDA test, we can evaluate the serious damage of pile during driving in site. In this study, we checked the damage of pile by pulling it out after evaluation of the pile damage during driving by PDA testing. After that, almost damaged pile was checked and the outline depth of damage could be verified. To increase the quality of driven pile, we have to increase the number of PDA testing for drivability analysis with checking the damage especially for preliminary pile driving and dynamic load test for checking the bearing capacity and consider the application of driving by energy monitoring.

  • PDF

Reinforcing Effects of Micro-Piles in a high Cut Slope (장대사면 내 억지말뚝의 억제효과 (현장 Case-Study 중심으로))

  • 정성윤;김경태;장기태;한희수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.374-381
    • /
    • 2002
  • Several sensor systems are used to estimate the reinforceing effect of pile in hihg cut slopes, and to find a failure zone in slopes effectively. Inclinometer, extensometer and V/W sensor have shown a great potentiality to serve real time health monitoring of the slope structures. They were embedded or attached to the structures, we conducted field tests and test results have shown great solutions for sensor systems of Civil Engineering Smart Structures. This research is to seek for the relationships among the slope movement and the reinforceing effect of pile, and the strain distribution in a active zone by analyzing the data from the in-situ measurement so that the possible failure zone should be well defined based on the relationships. Also, the relationships between temperature and reinforceing effect of pile, and the strain distribution are estimated in this paper.

  • PDF

1Monitoring system for the subway structures using pre-strain controllable FBG sensors (프리스트레인 가변형 광섬유센서를 이용한 지하철 구조 모니터링시스템)

  • Kim, Ki-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.700-709
    • /
    • 2009
  • FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well.

  • PDF

Evaluation of hydraulic fracturing of rockfill dam during first filling by measurement and numerical analysis (계측 및 수치해석에 의한 초기담수시 사력댐 코어존 수압할렬 안정성 분석)

  • Lee, Jong-Wook;Cho, Sung-Eun;Kim, Ki-Young;Lim, Heui-Dae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.799-805
    • /
    • 2008
  • In this study load transfer and hydraulic fracturing of core zone of object rockfill dam are estimated and monitored by a numerical analysis and a instrumentation immediately after the construction and during the first impounding. The estimated results are compared with the monitored results. It reveal that the core zone is safe on the hydraulic fracturing.

  • PDF

Geocomat를 활용한 폐기물매립장의 사면안정성 검토

  • 신은철;이성근;이영재
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.06a
    • /
    • pp.45-54
    • /
    • 2001
  • In this study, slope stability analysis of LCRS(Leachate Collection Removel System) in waste landfill was peformed by large scale field test. Geocomat is new type of geocomposite product. Gecomat is a sort of Geocomposite product. It is composed of nonwoven geotextiles, woven geotextile, and geonet. Large scale field tests were performed on the slope of different two LCRSsections with static loading condition. One is LCRS section witch consist of GCL, HDPE and Geocomat, another is GCL, HDPE, and woven type geocomposite. The behavior of geosynthetics lined slope was monitored by incorporating instrumentation including vertical soil pressure meter, settlement plate, strain gauges, potential meter, displacement pin.. Based on the field monitoring, the Geocomat LCRS section is less sliding than the conventional geocomposite LCRS section.

  • PDF