• Title/Summary/Keyword: geotechnical design

Search Result 1,815, Processing Time 0.026 seconds

The Bearing Capacity of Top Base Foundations in Soft Ground (연약지반상 팽이기초 적용에 따른 지지특성)

  • Kim, Chan-Kuk;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.401-414
    • /
    • 2010
  • Top Base Foundation(TBF) is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and restraining settlement of foundations when the bearing capacity of ground is not enough. However, when the design values from exiting Japanese standard are compared with the observation values from the field measurement, the bearing capacity of exiting standard estimated smaller For this reason, it is necessary to establish more reasonable prediction technique considering to understand the behavior of TBF in soft ground. In this study, 1/5 scale model tests were performed in the laboratory. Also, full scale tests were carried out in order to investigate the behavior of TBF with various shapes. In addition, about 100 sites measurement data were evaluated to investigate the behavior of TBF in various ground conditions. Based on the results of the model tests and field measurement data, it was possible to establish more reasonable the bearing capacity equation of TBF considering various N-value of soil, the effect of underground water and failure shapes.

  • PDF

A Case Study on Caisson Foundation Grouting in Geo-Ga Bridge (거가대교 케이슨기초 그라우트 충전 사례연구)

  • Bae, Kyung-Tae;Cha, Kyung-Seob;Kim, Young-Jin;Park, Chung-Whan;Jeong, Gyeong-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1046-1050
    • /
    • 2010
  • During construction of a sea-crossing bridge grouting was used to fill densely the space between the bottom of caisson and the ground. This grout mixture was mixed with an anti-washout admixture after locating accurately the pre-cast caisson on three concrete landing pads. This method differs significantly from the costly conventional method, for bridge foundations offshore, where concrete is placed in situ after excavating inside of a temporary concrete coffering wall. To verify the grouting method in advance, the full-scale field tests were performed twice on land. After identifying the fluidity of the grout material to be filled, finding some possible problems with the main construction and revising the original design, the main construction has been continuing successfully with 20 caissons completed to date. The purpose of this paper is to introduce for the first time in Korea the grouting method including the automatic and the manual monitoring system based on the main construction of the caisson foundation.

  • PDF

Effect of Input Soil Properties for Round Robin Test on Ground Response Analysis (지반 응답 해석 Round Robin Test의 입력 지반 물성에 따른 지반 응답 특성 영향 고찰)

  • Kim, Bong-Soo;Lee, Sei-Hyun;Choo, Yun-Wook;Park, Sung-Sik;Kim, Dong-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.305-316
    • /
    • 2007
  • Free field ground motion during earthquake is significantly affected by the local soil conditions and it is essential for the seismic design to perform the site specific ground response analysis. So, Round Robin Test (RRT) on ground response analysis was performed for three sites in Korea. A total of 12 teams presented the results of ground response analysis with used input soil properties based on own judgement. In this paper, the results of one dimensional equivalent linear analysis presented by 11 teams were compared to evaluate the effect of input soil properties on ground response analysis. Additionally, 4 influence factors on ground response analysis, that is shear wave velocity of soil layer, nonlinear dynamic deformational characteristics, bedrock depth and bedrock velocity were studied for assumed simple soil conditions.

  • PDF

Experiments Study on Critical Strain Properties of Sedimentary Rocks based on Mohr-Coulomb Strength Criterion (Mohr-Coulomb의 파괴기준을 기본으로한 퇴적암의 한계변형률 특성에 관한 연구)

  • Kim, Young-Su;Lee, Jae-Ho;Jin, Guang-Ril;Shin, Shi-Un;Kwon, Tea-Soon;Han, Hee-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.821-832
    • /
    • 2008
  • The hazard warning levels are necessary for the rational design and safety construction of underground space, as mountain and urban tunnel. Sakurai provided the hazard warning levels for assessing the stability of tunnels using the critical strain of rock mass, which is defined as a ratio between uni-axial compressive strength and the Young's modulus. The concept of critical strain guidelines is introduced in this study for the assessment of tunnel safety during excavation. Moreover, in this paper, the critical strain properties of sedimentary rock in Korea has investigated and analysed in detail by Lab. test, as the uniaxial and triaxial compression tests. Finally, critical strain properties of sedimentary rock on uniaxial and triaxial stress condition is discussed the relationship of failure strain values, uniaxial and triaxial compression strengths, confining pressure and Young's modulus.

  • PDF

A Construction Case of Massive Foundation for High Rise Building (A Case of Barrette Pile) (초고층 건축물 대형기초의 시공 사례 (바레트 말뚝 중심))

  • Joeng, Gyong-Hwan;Jung, Dong-Young;Moon, Jun-Bai;Kim, Dong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.90-104
    • /
    • 2007
  • The trend of current urban redevelopment and new city development project shows that the superstructure of building is getting larger and higher in consequence of a limited plottage condition and the preference of landmark. For this reason, it is definitely required to extend pile diameter and install the pilein deep foundation to support superstructure. The pile method causes construction-related problems such as increasing quantities, difficulty of storage & transportation material and decreasing design load while construct pile in deep foundation. The Bored Pile method has applied to minimize those problems. As above shown, this article will be presented construction case study of Barrette Pile and R.C.D in order to make a counterproposal for the quality control of a large building foundation work.

  • PDF

Influence of load transfer on anchored slope stability (앵커보강사면에서 안정해석시 하중전이의 영향)

  • Kim, Sung-Kyu;Park, Jong-Sik;Kim, Nak-Kyung;Joo, Yong-Sun;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1351-1358
    • /
    • 2008
  • This paper presents how the load transfer mechanism of the ground anchor affects on the stability analysis of anchored slope. The finite element analysis and the conventional limit equilibrium analysis on the anchored slope were performed and compared. The limit equilibrium analysis of the anchored slope is quite open used in design practice due to the easiness of the analysis. However, the load transfer mechanism is not considered properly for the analysis. When the failure surface passes through the bonded length of an anchor, the anchor load is disregarded and the factor of safety for the anchored slope is smaller than it should be. In this study, the load transfer distribution was incorporated into the limit equilibrium stability analysis of the anchored slope and the results were compared with the results of finite element analysis.

  • PDF

A Study of Field Loading Tests for Derivation of Load Transfer Curves of the Driven Steel Pipe Piles (타입 강관말뚝 하중전이곡선 도출을 위한 현장재하시험 연구)

  • Lim, Jong-Seok;Choi, Yong-Kyu;Ha, Hyuk;Sim, Jong-Sun;Park, Jong-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1188-1194
    • /
    • 2008
  • As computation technologies has developed, the analysis using load transfer is mainly performed. But most of the functions used in the above program has been developed in foreign countries. Also in our nation, lots of studies concerning load transfer are being researched. The investigation of suitability about the piles installed in our grounds, however, is required as functions acquired experientially, basing on the piles installed in foreign grounds. In this background, the load transfer curve required to use load transfer method on its design through the analysis of field tests inside our nation intends to be made, on which this research focuses.

  • PDF

Prediction of rock fragmentation and design of blasting pattern based on 3-D spatial distribution of rock factor

  • Sim, Hyeon-Jin;Han, Chang-Yeon;Nam, Hyeon-U
    • 지반과기술
    • /
    • v.3 no.3
    • /
    • pp.15-22
    • /
    • 2006
  • The optimum blasting pattern to excavate a quarry efficiently and economically can be determined based on the minimum production cost, which is generally estimated according to rock fragmentation. Therefore, it is a critical problem to predict fragment size distribution of blasted rocks over an entire quarry. By comparing various prediction models, it can be ascertained that the result obtained from Kuz-Ram model relatively coincides with that of field measurements. Kuz-Ram model uses the concept of rock factor to signify conditions of rock mass such as block size, rock jointing, strength and others. For the evaluation of total production cost, it is imperative to estimate 3-D spatial distribution of rock factor for the entire quarry. In this study, a sequential indicator simulation technique is adopted for estimation of spatial distribution of rock factor due to its higher reproducibility of spatial variability and distribution models than Kriging methods. Further, this can reduce the uncertainty of predictor using distribution information of sample data. The entire quarry is classified into three types of rock mass and optimum blasting pattern is proposed for each type based on 3-D spatial distribution of rock factor. In addition, plane maps of rock factor distribution for each ground level are provided to estimate production costs for each process and to make a plan for an optimum blasting pattern.

  • PDF

Development of Nutrients and Heavy Metals Removal Technology in Saturated Zone Using Zeolite (포화 지층내 영양염류 및 중금속의 제거를 위한 제올라이트의 적용인자 도출)

  • 이승학;이재원;박준범;전연호;이채영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.435-442
    • /
    • 2000
  • Batch test and column test were performed to develop the design factors for permeable reactive barriers(PRBs) against ammonium and heavy metals, Clinoptilolite, a kind of natural zeolites having excellent cation exchange capacity(CEC), was choosen for the reacting materials through the ion-exchange mechanism. In the batch test, the reactivity of clinoptilolite for ammonium, lead, and copper was examined varying the initial concentration of contaminants(ammonium: 20, 40, 80 ppm, heavy metals: 10, 20, 40 ppm) and the particle size of clinoptilolites(0-0.15, 0.42-0.85, 1-1.25 mm). The reactivity is increasing as the initial concentration decrease and particle size decrease. In the column test, the permeability and the reactivity of the specimens were examined using flexible-wall permeameter. Specimens were made of clinoptilolite and Jumunjin-sand with 20 : 80 weight ratio varying particle size of clinoptilolite. The maximum permeability(1${\times}$10$\^$-4/-5${\times}$10$\^$-5/cm/s) was achieved in the specimen made of 0.42-0.85 mm clinoptilolite and sand.

  • PDF

Ground Vibration in Tunnelling by Blasting and its Effect on Surface Structures (터널굴착이 지상구조물에 미치는 영향평가 및 발파지침설계)

  • 신희순;한공창;류창하;신중호;박연준;최영학
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.463-470
    • /
    • 2000
  • In tunnel excavation by blast beneath the surface structures in urban area, the characteristics of ground vibration induced by blast and its influence on surface structures are analyzed by the field test and the numerical analysis on dynamic behaviors of the structure. According to the field test on the propagating characteristics of blast vibration through the rock mass and the concrete foundation pile. the attenuation index of peak particle velocity with distance shows the range of 1.7∼2.0 for the rock mass and the range of 2.0∼2.3 for the concrete pile. This shows that the blast vibration reduces more rapidly in the concrete pile. It is known from the numerical analysis on dynamic behavior of the structure that the coefficient of response, velocity ratio of structure response to input wave, is different according to the story of the structure. It can be said from this research that the characteristics of the ground vibration and the dynamic behavior of the structure should be well evaluated and be considered as important factors for safe blasting design especially in underground excavation at shallow depth in urban area.

  • PDF