• Title/Summary/Keyword: geometrical distribution

Search Result 334, Processing Time 0.023 seconds

Effect of Asymmetric Electrode Structure on Electron Emission of the Pb(Zr0.8Ti0.2)O3 Ferroelectric Cathode (Pb(Zr0.8Ti0.2)O3강유전 음극에서 비대칭 전극구조가 전자 방출 특성에 미치는 영향)

  • 박지훈;김용태;윤기현;김태희;박경봉
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.92-98
    • /
    • 2002
  • To investigate the electrode structural effect on the ferroelectric electron emission, the electric field distribution in a 2-dimensional structure was calculated as a function of upper electrode diameter, and the switching charge density and emission charge were measured simultaneously. The simulation of the electric field distribution showed that an asymmetric electrode structure could cause a stray field on the bare surface of the ferroelectric cathode near the edge of upper electrode. The distance of stray field from the electrode edge increased with increasing ferroelectric thickness, but it did not depend on the upper electrode diameter. The switching charge density increased more on the cathode with smaller upper electrode diameter. This was attributed to the stray field on the bare ferroelectric surface near the electrode edge, because the stray field for the asymmetric ferroelectric cathode enhanced polarization switching near the electrode edge. From the switching charge density, the distance of stray field from the electrode edge was calculated as about 11-14${\mu}{\textrm}{m}$. The threshold voltage of electron emission was 61-68 kV/cm, which was almost 3 times lager than the coercive voltage. The threshold voltage was not determined just by coercive voltage, but by strength and distance of the stray-field, which largely depended on the geometrical structure of ferroelectric cathode.

Simulation of Velocity Distribution in the Lake "Paldang" using the RMA-2 Model (수리모형(RMA-2)을 이용한 팔당호의 유속분포 모의실험)

  • Shin, Dong-Seok;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 1999
  • A numerical model of flow velocity in the standing water system is presented. This model(RMA-2), based on the 2-dimensional unsteady momentum and continuity equations, uses finite element techniques to simulate the distribution of velocity over a spatial location of lakes. The present model represents an improvement over existing numerical water quality models in that it can model the unsteady state and can, therefore, cope with time with a spatial location of standing waters such as lakes and large reservoirs. The model thus allows the engineer to do more accurate estimation of water flows and thus water qualities in standing waters where directions and velocities of the flow become more important for the simulation of the water quality than in running waters. Tests for the data collected in the lake "Paldang" indicates that the model works well under limited circumstances. However, to be more accurate estimation of velocity with the present model, accumulation of data for the measurement of velocities and renovation of geometrical conditions of the lake would be needed.

  • PDF

Cable Adjustment of Composite Cable Stayed Bridge with Fuzzy Linear Regression Analysis (선형퍼지회귀분석기법을 이용한 합성형 사장교 케이블의 장력보정)

  • Kwon, Jang Sub;Chang, Seung Pil;Cho, Suh Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.579-588
    • /
    • 1997
  • During the construction of cable stayed bridge, errors are always caused by various reasons, accumulated and amplified through the complex construction steps. It is likely that the undesirable stress distribution of members and the large deflection of the bridge different from design values come out The adjustment of cables during construction is absolutely indispensable to correct the stress distribution of the members and the geometrical configuration of the bridge. In the conventional method, weight coefficients are used to consider the difference of units between cable forces and girder deflections during the optimization process of cable adjustment. However, it is not easy to determine weight coefficients and the adjustment must be repeated several times with the time consuming process of the determination of new weight coefficients in case that errors are out of design allowable limits. In this paper, fuzzy linear regression analysis is applied to the cable adjustment to overcome those problems. In the application of fuzzy linear regression analysis method the designer's intention and the design allowable limits can be formulated in the form of the constraints of the linear optimization problem. Therefore, the cable adjustment in construction site can be carried out with the fuzzy linear regression analysis more rapidly than with the convetional method.

  • PDF

Shear Capacity of Reinforced Concrete Continuous T-Beams Externally Strengthened with Wire Rope Units (와이어로프로 외부 보강된 철근콘크리트 연속 T형 보의 전단내력)

  • Yang, Keun-Hyeok;Sim, Jae-Il;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.773-783
    • /
    • 2007
  • A simple unbonded-type shear strengthening technique for reinforced concrete beams using wire rope units is developed. Six two-span continuous T-beams externally strengthened with wire rope units and an unstrengthened control beam were tested. The main variables investigated were the amount and prestressing force of wire rope units. All specimens had the same geometrical dimension and arrangement of internal reinforcement. Influence of the distribution of vertical stresses in beam web owing to the prestressing force of wire rope units on the diagonal shear cracking load and the ultimate shear capacity of beams tested is presented. Based on the current study, it can be concluded that the amount and initial prestress of wire rope should be limited to be above 2.5 times the minimum shear reinforcement ratio specified in ACI 318-05 and below 0.6 times its own tensile strength, respectively, to ensure the enhancement of shear capacity and ductile failure mode of the strengthened beams. A numerical analysis based on the upper-bound theorem is developed to assess the shear capacity of continuous T-beams strengthened with wire rope units. From the comparisons of measured and predicted shear capacities, a better agreement is achieved in the proposed numerical analysis than in empirical equations recommended by ACI 318-05.

The Analysis of Regional Scale Topographic Effect Using MM5-A2C Coupling Modeling (국지규모 지형영향을 고려하기 위한 MM5-A2C 결합 모델링 특성 분석)

  • Choi, Hyun-Jeong;Lee, Soon-Hwan;Kim, Hak-Sung
    • Journal of the Korean earth science society
    • /
    • v.36 no.3
    • /
    • pp.210-221
    • /
    • 2015
  • The terrain features and surface characteristics are the most important elements not only in meteorological modeling but also in air quality modeling. The diurnal evolution of local climate over complex terrain may be significantly controlled by the ground irregularities. Such topographic features can affect a thermally driven flow, either directly by causing changes in the wind direction or indirectly, by inducing significant variations in the ground temperature. Over a complex terrain, these variations are due to the nonuniform distribution of solar radiation, which is highly determined by the ground geometrical characteristics, i.e. slope and orientation. Therefore, the accuracy of prediction of regional scale circulation is strong associated with the accuracy of land-use and topographic information in meso-scale circulation assessment. The objective of this work is a numerical simulation using MM5-A2C model with the detailed topography and land-use information as the surface boundary conditions of the air flow field in mountain regions. Meteorological conditions estimated by MM5-A2C command a great influence on the dispersion of mountain areas with the reasonable feature of topography where there is an important difference in orographic forcing.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(4) - Velocity Profile(2) (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(4) - 유속분포(2))

  • Park, Chanjun;Sung, Jaeyong;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.242-254
    • /
    • 2016
  • This paper is the forth investigation on the evaluation methods of flow characteristics in a steady flow bench. In the previous works, it was concluded that the assumption of the solid rotation might cause serious problems and both of the eccentricity and the velocity profile distort the flow characteristics when using the ISM at 1.75B plane. Also particle image velocimetry (PIV) measurement at this position showed that the real velocity profile was far from the assumption of ISM evaluation. In this paper, the planar velocity profiles were measure from 1.75B to 6.00B position by PIV and the characteristics were examined according to the valve angles and lifts for further investigations about the effect of the position on the velocity profile. The results show that $26^{\circ}$ valve angle is always an unique exceptional case in all aspects. If the valve angle is $21^{\circ}$ and below, the planar velocity profiles according to the lift and the position are similar to each other, however, the tangential velocity curves along with the radial direction have common tendencies up to $16^{\circ}$ angle. Also the well arranged swirl behaviors are generally observed at the position above 3.00B and the velocity contour lines come closer to the concentric circle as the valve lift increases. In addition, the gradient of tangential velocity along with the radial direction from the swirl center becomes stable and constant as the position goes downstream. Concurrently the velocity gradient is larger to the eccentric direction of the center. In the meantime the tangential velocity curves along with the radial direction are irregular and various at 1.75B, however, they become regular and reach higher level as the evaluation position goes downstream. At this time the curves of 4.50B are the best fitted to the ideal one. On the other hand in an exceptional case, $26^{\circ}$, the velocity contours are very complicated over 6mm valve lift regardless the position and the gradient increases to the opposite direction of the eccentric center. Also, 6.00B is a best fitting position in the geometrical cylinder center base. With respect to the swirl center, the distribution range of centers for 1.75B is different to that for the other positions and the eccentricities of this plane are larger regardless the valve angle. After 1.75B, there is no certain tendency in the center position change according to the valve angle and lift. Additionally, the eccentricities are not sufficiently small to neglecting the effect on ISM measurement.

The Study and Measurement of Three Dimensional Spatial Dose Rate from Radioiodine Therapy (고용량 옥소 치료 시 3차원적 공간선량률 측정 및 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.251-257
    • /
    • 2013
  • Spatial dose rates of high dose $^{131}I$ therapy patients were Measured Three dimensional (X, Y, Z) distributions. I have constructed geometrical an aluminum support structure for spatial dose meters placed in 5 different heights, 8 different azimuthal angles, 6 different time interval and distance 100 cm from High dose$^{131}I$ therapy patients. when the height of vertical plane Spatial dose distribution is 100 cm, the Spatial dose rates is max and the error range is low. the vertical plane Spatial dose rates was found to be 71.85 ${\mu}Sv/h$ on the average at a distance of 100 cm, height 100 cm, from the patients 24 hours after $^{131}I$ oral administration. I divided 12 patients into two groups. I have analysed group A (drinking 5 L water) and group B (drinking 3 L water) in order to measure decrease spatial dose rates. I have found the spatial distributions of patient dose rates is $44.9{\pm}7.2$ ${\mu}Sv/h$ in group A and $100.3{\pm}8.1$ ${\mu}Sv/h$ in group B by 24 after $^{131}I$ oral administration. the reduction factor was found to be approximately 54 % through drinking 5 L water during 24 hours.

A New Strategy to Fabricate a Colloidal Array Templated $TiO_2$ Photoelectrode for Dye-sensitized Solar Cells

  • Lee, Hyeon-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.8.1-8.1
    • /
    • 2011
  • Nanocrystalline titanium dioxide ($TiO_2$) materials have been widely used as an electron collector in DSSC. This is required to have an extremely high porosity and surface area such that the dye can be sufficiently adsorbed and be electronically interconnected, resulting in the generation of a high photocurrent within cells. In particular, their geometrical structures and crystalline phase have been extensively investigated as important issues in improving its photovoltaic efficiency. In this study, we present a new strategy to fabricate a photoelectrode having a periodic structured $TiO_2$ film templated from 1D or 3D polystyrene (PS) microspheres array. Monodisperse PS spheres of various radiuses were used for colloidal array on FTO glasses and two types of photoelectrode structures with different $TiO_2$ materials were investigated respectively. One is the igloo-shaped electrode prepared by $TiO_2$ deposition by RF-sputtering onto 2D microsphere-templated substrates. At the interface between the film and substrate, there are voids formed by the decomposition of PS microspheres during the calcination step. These holes might be expected to play the predominant roles as scattering spherical voids to promote a light harvesting effect, a spacious structure for electrolytes with higher viscosity and effective paths for electron transfer. Additionally the nanocrystalline $TiO_2$ phase prepared by the RF-sputtering method was previously reported to improve the electron drift mobility within $TiO_2$ electrodes. This yields solar cells with a cell efficiency of 2.45% or more at AM 1.5 illumination, which is a very remarkable result, considering its $TiO_2$ electrode thickness (<2 ${\mu}m$). This study can be expanded to obtain higher cell efficiency by higher dye loading through the increase of surface area or multi-layered stacking. The other is the inverse opal photonic crystal electrode prepared by titania particles infusion within 3D colloidal arrays. To obtain the enlargement of ordered area and high quality of crystallinity, the synthesis of titania particles coated with a organic thin layer were applied instead of sol-gel process using the $TiO_2$ precursors. They were dispersed so well in most solvents without aggregates and infused successfully within colloidal array structures. This ordered mesoporous structure provides the large surface area leading to the enough adsorption of dye molecules and have an light harvesting effect due to the photonic band gap properties (back-and-forth reflection effects within structures). A major advantage of this colloidal array template method is that the pore size and its distribution within $TiO_2$ photoelectrodes are determined by those of latex beads, which can be controlled easily. These materials may have promising potentials for future applications of membrane, sensor and so on as well as solar cells.

  • PDF

Experimental Validation of Isogeometric Optimal Design (아이소-지오메트릭 형상 최적설계의 실험적 검증)

  • Choi, Myung-Jin;Yoon, Min-Ho;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 2014
  • In this paper, the CAD data for the optimal shape design obtained by isogeometric shape optimization is directly used to fabricate the specimen by using 3D printer for the experimental validation. In a conventional finite element method, the geometric approximation inherent in the mesh leads to the accuracy issue in response analysis and design sensitivity analysis. Furthermore, in the finite element based shape optimization, subsequent communication with CAD description is required in the design optimization process, which results in the loss of optimal design information during the communication. Isogeometric analysis method employs the same NURBS basis functions and control points used in CAD systems, which enables to use exact geometrical properties like normal vector and curvature information in the response analysis and design sensitivity analysis procedure. Also, it vastly simplify the design modification of complex geometries without communicating with the CAD description of geometry during design optimization process. Therefore, the information of optimal design and material volume is exactly reflected to fabricate the specimen for experimental validation. Through the design optimization examples of elasticity problem, it is experimentally shown that the optimal design has higher stiffness than the initial design. Also, the experimental results match very well with the numerical results. Using a non-contact optical 3D deformation measuring system for strain distribution, it is shown that the stress concentration is significantly alleviated in the optimal design compared with the initial design.

Influence of Inclined Reinforcement around Openings on the Shear Behavior of Reinforced Concrete Continuous Deep Beams (철근콘크리트 연속 깊은 보의 전단 거동에 대한 개구부 경사 보강근의 영향)

  • Chung, Heon-Soo;Sim, Jae-Il;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.171-178
    • /
    • 2007
  • Twelve reinforced concrete continuous deep beams having web openings within interior shear spans were tested to failure. All beams tested had the same geometrical dimensions. The main variables investigated were the opening size and amount of inclined reinforcement around openings. An effective inclined reinforcement factor combining the influence of the opening size and amount of inclined reinforcement on the structural behavior of the beams tested is proposed. It was observed that the load distribution, diagonal crack width, and load capacity of beams tested were greatly dependent on the effective inclined reinforcement factor which ranged from 0 to 0.171 for the test specimens. The higher this factor, the smaller the diagonal crack width and its development rate. A higher load capacity also developed in beams having effective inclined reinforcement factor above 0.077 than in the corresponding solid deep beams. A numerical technique based on the upper bound analysis of the plasticity theory is proposed to evaluate the load capacity of continuous deep beams having openings within interior shear spans. Predictions obtained from the proposed formulas are in good agreement with test results.