• 제목/요약/키워드: generation load of pollutants

검색결과 15건 처리시간 0.024초

낙동강 소유역 경지에서의 비점오염원 물질 발생 및 배출 특성 (Generation and Discharge Characteristics of Non-point Pollutants from Farmlands of Small Watershed for Nak-dong River)

  • 정용준;남광현;민경석
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.333-338
    • /
    • 2004
  • This study was carried out to investigate the generation and discharge characteristics of non-point pollutants from farmlands in Nak-dong river basin. Annual unit generation load of nitrogen and phosphorus by fertilization in the test paddy field was almost similar to those calculated by the fertilization standards of district agricultural technology center, but it was extremely higher in case of the test dry field. By comparing annual total generation load of nutrients from fertilization to the data of fertilizer marketing, the accurate forecasting of generation load of pollutants was achieved by marketing data. The annual total discharge ratio of nutrients through infiltration and overflow from the farmland of the test paddy field were 9.5% and 1.1%, respectively, and those in the test dry field were 22.0% and 0.1%, respectively. The monthly discharge load of nutrients were shown the highest proportioned to the discharge load from lands, but it showed higher in phosphorus, which was caused by the intermittent discharge of phosphorus accumulated in drainage.

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

소규모 폐수배출시설 관리 강화의 필요성 (Necessity of Strengthening Small-Scale Wastewater Discharge Facilities Management)

  • 박재홍;류덕희
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.226-233
    • /
    • 2018
  • Small-scale wastewater discharge facilities account for 98% of all workplaces, but in the generation and emission of major pollutants, they account for 27.5 % and 23.5 %, respectively. Since the proportion of the emission load of the small-scale workplace is not large, the national environmental policy has been established mainly around large-scale wastewater discharge facilities. However, in the case of specific hazardous substances in water, the amount of the discharge load of the small-scale wastewater discharge facility was 2.4 times higher than that of the generation load. Certain types of specific hazardous substances in water, which have a higher discharge load than large-scale wastewater discharge facilities, account for 24 ~ 32 %. There are also cases in which the discharge load from a small-scale discharge facility is more than four times higher, depending on the specific kind of water pollutant. As a result of inspections, the violation rate of the small-scale wastewater discharge facility among the total violations by facilities is 93.9 ~ 97.5 %. As a result, the ecotoxicity value of small-scale wastewater discharge facilities was high in most industries, and there was a fluctuation in the measured value. This indicates that the ecological integrity of the water system can be largely influenced by small-scale wastewater discharge facilities. Therefore, it is necessary to expand the environmental management of small-scale wastewater discharge facilities, and in some cases, the effect of the improvement in quality may be more significant than in the management of large-scale wastewater discharge facilities.

Correlation Analysis on the Runoff Pollutants from a Small Plot Unit in an Agricultural Area

  • Kang, Meea;Choi, Byoung-Woo;Lee, Jae-Kwan
    • Environmental Engineering Research
    • /
    • 제15권4호
    • /
    • pp.191-195
    • /
    • 2010
  • This study was carried out to investigate the important factors relating to runoff and pollutant loads in a plot unit located in an agricultural area. Of the precipitation parameters, such as total precipitation, days since last rainfall (ADD, the rainfall was more than 10mm) and average rainfall intensity on runoff, the strongest effect was obtained due to total precipitation, but the rainfall intensity showed a slightly positive correlation. It was expected that both variables, i.e. total precipitation and rainfall intensity, would lead to the generation of greater runoff. In contrast, runoff was negatively correlated with ADD, which is understandable because more infiltration and less runoff would be expected after a long dry period. The TSS load varied greatly, between 75.6 and $5.18{\times}10^4g$, per event. With the exception of TN, the TSS, BOD, COD and TP loads were affected by runoff. The correlations of these items were proportional to the runoff volume, with correlation coefficients (r) greater than 0.70, which are suitable for use as NPS model data. The TSS load showed very good relationships with organics (BOD & COD) and nutrients (TN & TP), with correlation coefficients greater than 0.79. Therefore, the removal of TSS is a promising factor for protecting water basins.

저온 플라즈마 공정용 펄스발생 전원장치의 성능시험 (Test Results of Pulsed Power Supply for Nonthermal Plasma Process)

  • 장성덕;변영철;조무현;신동남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안 (Effect and Control of the Sediment in the Combined Sewer on CSOs)

  • 임봉수;김도영;이광춘
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

육수학적 특성에 따른 국내 저수지의 부영양화 유형분석 -엽록소 a와 수심을 중심으로 (Analysis of Eutrophication Based on Chlorophyll-a, Depth and Limnological Characteristics in Korean Reservoirs)

  • 김호섭;황순진
    • 생태와환경
    • /
    • 제37권2호통권107호
    • /
    • pp.213-226
    • /
    • 2004
  • 본 연구에서는 엽록소 a 농도와 저수지의 수심을 토대로 유형을 분류하고 각 유형에서의 수질특성을 평가하였다. 486개의 저수지를 대상으로 엽록소 a 농도 25 ${\mu}g\;L^{-1}$와 수심 7.5m를 기준으로 4가지 유형으로 분류하였다. 각 호수에서의 연평균 최대 엽록소 a 농도를 기초로 OECD와 TSI 기준에 따라 평가 시 각각 34.3%와 72.8%가 부영양상태였다. 엽록소 a 농도 25 ${\mu}g\;L^{-1}$를 기준으로 구분된 유형들에서 총질소 농도(2배) 보다는 총인 (4배)의 농도차이가 크게 나타났다. TN/TP비를 토대로 할 때 인이 제한 영양염으로 나타났고, 영양상태가 높은 저수지들에서 인에 대한 제한정도가 큰 것으로 나타났다. 엽록소 a 농도가 가장 높은 TYPE II에 포함된 저수지는 상대적으로 노후된 시설이 많고 DA/LA비가 작으며 체류시간이 길고 유역 내 논과 밭으로 이용되는 면적이 넓고 유역에서 발생하는 오염부하가 많았다. 비록 유역면적이 유역내에서의 오염물질 발생부하량과 관련된 요인으로 고려될 수 있으나 수질과의 뚜렷한 상관성이 없었다. 본 연구에서 수심이나 시설물의 노후정도와 같은 형태학적인 특성과 더불어 유역 내의 토지이용형태는 저수지의 수질을 결정하는 매우 주요한 인자로 나타났고 수질 특성을 평가함에 있어 효과적인 인자로 제시되었다.

수질오염총량 단위유역별 LDC(Load Duration Curve, 부하지속곡선) 적용을 통한 수질관리 대안 모색 - 금호강 유역 대상 (Water Quality Management Measures for TMDL Unit Watershed Using Load Duration Curve)

  • 윤소영;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.429-438
    • /
    • 2013
  • This study was to develop effective water quality management measures using LDC (Load Duration Curve) curves for TMDL (Total Maximum Daily Loads) unit watershed. Using LDC curves, major factors for BOD and T-P concentration loads generation (i.e. point source or non-point source) in the case study area (Geumho river basin) were found for different hydrologic conditions. Different measures to deal with the pollutant loads were suggested to establish BMPs (Best Management Practices). It was found that the target area has urgent T-P management methods especially at moist and midrange hydrologic conditions because of point source pollutants occurred in developed areas. One example measure for this could be establishment of advanced treatment facility. This study proved that the use of LDC was a useful way to achieve TWQ (Target Water Quality) on the target watershed considered. It was also expected that the methodology applied in this study could have a wider application on the establishment of watershed water management measures.

영산강과 섬진강 유역의 하천 수질환경 평가 (Estimation of Water Quality Environment in Youngsan and Seumjin River Basins)

  • 양해근;최희철
    • 대한지리학회지
    • /
    • 제38권1호
    • /
    • pp.16-31
    • /
    • 2003
  • 본 연구에서는 영산강과 섬진강의 유역을 대강으로 하천수질 환경관리에 가장 중요한 인자로 간주되는 종합적 수질지표(WQI)와 비유달부하량에 대한 개념을 도입하여 유역별 수질환경을 파악하였으며. 하천수질 형성에 영향을 미치는 인위적인 요인을 규명하였다. 영산강 유역의 비유달부하량은 8.34∼97.25kg/day/$\textrm{km}^2$로 나타났으며. 고막원천과 광주천유역에서 각각 97.25kg/day/$\textrm{km}^2$. 86.06kg/day/$\textrm{km}^2$로 높게 나타났다. 섬진강 유역의 비유달부하량은 10.98∼19.51kg/day/$\textrm{km}^2$로서. 오염 기여도가 높은 유역이 없는 것으로 밝혀졌다. WQI는 영산강 유역에서 1.36∼3.45인 반면에 섬진강 유역에서는 0.5~1.47로 비교적 낮은 수질 오염도를 나타냈다. 유역의 종합적 환경관리를 위해서는 유역별 오염 발생량과 하천 자정능력을 고려한 하천의 오염물질 수용한계에 대한 분석이 전제되어야 하며, 본 연구에서 제시한 비유달부하량은 오염물질 수용한계에 대한 기초 자료로서 그 가치가 있다고 볼 수 있다.

합리적인 유역단위 오염부하량 산정방법 연구 (Calculation of Pollutant Load for Prediction of Pollutant Loads to Watershed)

  • 장재호;윤춘경;정광욱;김형철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.534-539
    • /
    • 2005
  • The purpose of this study is the introduction of pollutant loads's estimation into Saemangeum watershed area with M.E.'s guidebook for TMDL and GIS tool. To estimate reliable pollutants loads, it is necessary to think about characteristic of removal, discharge and runoff as time series. In this study, it was calculated for generation loads which be came from pollutant source, discharge loads which be reduced in the treatment facilities and delivery loads which be considered the self purification parameter and delivery distance. To assess the delivery distance handily, it was particularly estimated using Arc-GIS. It was met with good results that delivery loads of BOD, T-N and T-P was reflected to seasonal precipitation. Lastly to verify the estimated pollutant loads, HSPF developed by USEPA was applied to it. It was showed a relativity of observed to simulated data for flow, Temperature, DO, BOD, $NO_3^--N$ TN and TP. Consequantly, this delivery loads can make full use of model input data for prediction of pollutant loads.

  • PDF