• 제목/요약/키워드: generated voltage

검색결과 1,370건 처리시간 0.028초

3상전압을 이용한 중첩방전형 오존발생기의 특성 (The Characteristics of Superposed Ozonizer using Three-Phase Voltage)

  • 김영훈;전병준;송현직;윤영대;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

고전계 인가 산화막의 트랩 분포 (Trap distributions in high voltage stressed silicon oxides)

  • 강창수
    • 한국결정성장학회지
    • /
    • 제9권5호
    • /
    • pp.521-526
    • /
    • 1999
  • 산화막 트랩은 스트레스 바이어스 전압에 의해 산화막 계면과 산화막 안에 생성됨을 조사하였다. 이러한 실험은 게이트 면적 1$10^{-3}\textrm{cm}^2$를 갖는 산화막 두께 범위가 113.4$\AA$에서 814$\AA$까지의 산화막 안에서 상대적 트랩 위치를 결정하였다. 트랩은 캐소우드 부근에 음전하, 애노우드 부근에 양전하로 충전되어 있다. 트랩의 전하상태는 스트레스 고전압 인가 후 낮은 전압인가에 의해 쉽게 변화되었다. 고전압 스트레스에 의해 발생된 트랩의 산화막 전하상태는 양 또는 음전하를 포함한다.

  • PDF

펄스전류 운전에 따른 KSTAR PF 초전도자석의 퀜치 분석 및 퀜치 검출 시스템 운전 특성 (Quench Analysis and Operational Characteristics of the Quench Detection System for the KSTAR PF Superconducting Coils)

  • 추용;요네가와;김영옥;이현정;박갑래;오영국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.20-25
    • /
    • 2009
  • The quench detection system of the KSTAR (Korea Superconducting Tokamak Advanced Research) primarily uses the resistive voltage measurement due to a quench. This method is to detect the resistive voltage generated by a quench, which is continuously maintained above the preset voltage threshold for a given holding time. As the KSTAR PF (Poloidal Field) coils are operated in the pulse current mode, the large inductive voltages are generated. Therefore the voltage threshold and the quench holding time should be determined by considering both the inductive voltages measured during the operation, and the maximum conductor temperature rise through the quench analysis. In this paper, the compensation methods for minimizing the inductive voltages are presented for the KSTAR PF coils. The quench hot spot analysis of the PF coils was carried out by the analytical and numerical methods for determining the proper values of the quench voltage threshold and the allowable quench protection delay time.

Design of charge pump circuit for analog memory with single poly structure in sensor processing using neural networks

  • Chai, Yong-Yoong;Jung, Eun-Hwa
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.51-56
    • /
    • 2003
  • We describe a charge pump circuit using VCO (voltage controlled oscillator) for storing information into local memories in neural networks. The VCO is used for adjusting the output voltage of the charge pump to the reference voltage and for reducing the fluctuation generated by the clocking scheme. The charge pump circuit is simulated by using Hynix 0.35um CMOS process parameters. The proposed charge pump operates properly regardless to the temperature and the supply voltage variation.

전력용반도체 소자를 이용한 새로운 고전압 펄스발생회로 (High Voltage Pulse Generator using Power Semiconductor Switches)

  • 이영운
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.30-33
    • /
    • 2000
  • Using power semiconductor switches such as IGBTs diodes and L-C circuits novel repetitive impulse voltage generator is developed. In the presented circuits high voltage pulse is generated by series-connection of capacitors and IGBTs. The charging of capacitors and voltage balance of IGBTs is done automatically. To verify the proposed circuit 20kV, 300A pulse generator is manufactured and tested.

  • PDF

전압인가식 제전기의 특성에 관한 연구 (A Study on Characteristics of a Volatage-Applied Electrostatic Reducer)

  • 이동훈;정용철
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.77-83
    • /
    • 1995
  • An electrostatic reducer of a multi-pole high DC voltage applied type and a high frequency square wave voltage applied type have been studied to eliminate effectively and safely electrostatic charge on a dummy charged material. As a fundamental experiments, measurement were made on the decay time as a function of distance between electrostatic reducer and charged body, skewed angle of electrostatic reducer installed and wind speed of generated ions(+ or -) by electrostatic reducer with high DC voltage and high frequency square wave voltage. Based oil the results above, a appropriate installation and method were produced as a trial for factory.

  • PDF

철도레일 복합 압전패드의 구성 차이에 따른 전압 발생 특성 분석 (Analysis of Voltage Generating Characteristics of Composite Rail Pad Composed of Piezoelectric PVDF Film and Polyurethane Bonding Materials)

  • 조호진;임유진;김성수;이종관
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.381-386
    • /
    • 2017
  • A railway track generates severe levels of vibrations. In order to reduce these vibrations and to provide structural stability, various rail pads, mats, etc., are used for vibration protection. In this study, a specially designed rail pad was developed to reduce vibration and to generate electric power simultaneously, that is, by using the vibrations generated by railway cars on the track. The newly developed rail pads were tested to evaluate the characteristics of electric power by investigating the generated voltage and the current levels and patterns. In addition, we proposed an optimal laminated structure and adhesive by comparing the voltage generated by each type of adhesive required for optimal adhesion of the rail pad and the piezoelectric device.

FCAW에서 용접금속 확산성수소량에 미치는 용접변수 영향의 정량적 해석 (Quantitative Analysis on the Effects of Welding Parameters on Diffusible Hydrogen Contents in Weld Metal Produced by FCAW Process)

  • 한동우;방국수;정홍철;이종봉
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.54-59
    • /
    • 2010
  • The effects of welding parameters such as contact tip-to-work distance (CTWD), voltage, and current on the weld metal diffusible hydrogen contents (HD) were investigated and rationalized by the calculation of heating time and amount of heat generated in the extension length of flux cored wire. As CTWD increased from 15 to 25mm, HD decreased from 8.46 to 5.45mL/100g deposited metal. Calculations showed that, with an increase of CTWD, the amount of heat generated increased from 46 to 92J in addition to an increase of heating time. Increase of current from 250 to 320A, however, gave little variation of HD. It showed that no significant change in the amount of heat generated was found, and heating time was decreased with an increase of current. It also showed that CTWD is more influential than voltage in relatively lower heat input ranges, while voltage is more in higher input ranges

수중 아-크 방전음원에 관한 연구 (ARC Discharge Sound Source in Underwater)

  • 장재환;장지원
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.12-18
    • /
    • 1985
  • 고압변압기의 1차측을 제어하고 2차측에 유도된 전압을 이용한 수중방전음원의 전기음향학적 제특성을 분석.검사한 결과는 다음과 같다. 1. 방전시 2차측 전류는 초기에는 Ohm 법칙을 따르다가 전류가 최고 6.3A 흘러 절연 파괴되었으며, 그 순간 방전음이 생성되었다. 2. 전류인가점과 방전음 생성문의 시간차는 약 3ms였으며, 전압이 최고일 때 절연파괴가 일어나 방전음이 생성되었다. 3. 전극의 끝이 뾰족할수록 2차측 전압이 높을수록 음압수준은 높았다. 4. 뾰족한 형태의 전극은 전극간격이 100cm일 때도 방전이 일어났으며 전극간격이 1cm이상부터 비교적 안정된 방전음이 생성되었다. 5. 방전음의 펄스폭은 약 0.15ms인 Shock Wave였으며, 10HKz 이하의 합성저주파 성분이었다.

  • PDF

A Study on Synchronized AC Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic Effect

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Kim, Jong-Lae;Jang, Byong-Gon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.547-553
    • /
    • 1998
  • In this paper, we composed of utility interactive pv generation system of voltage source inverter, and represented uninterrutible power supply (UPS) equipment maintaining constant voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to dc side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF