• Title/Summary/Keyword: generated voltage

Search Result 1,370, Processing Time 0.027 seconds

Comparison Study of AAS and ISE Method in the Lithium Analysis of Serum and Urine (혈액 및 소변의 Lithium치 측정에 있어서 AAS법과 ISE법의 비교)

  • Lee, Soo-In;Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.409-416
    • /
    • 1993
  • In the method for lithium (Li) analysis, flame emission photometry and atomic absorption spectrophotometry (AAS) have been used most frequently. In addition, lithium can be analyzed by ion-selective electrode (ISE) or fluorscence polarization immunoassay. We evaluated the comparison between AAS method based on the principle of absorption of light at 670.8 nm by Li and ISE method based on the principle of voltage difference generated by Li in contact with lithium ionophore. We compared with those obtained by AAS (AA/AE Spectrophotometer 551, Instrumentation Laboratory Co.) and ISE(CSYNCHRON EL-ISE, Beckman Co.) in the serum and urine of 6 patients and evaluated time-related changes of serum lithium concentration after dosing in both methods. The results are summarized as follows : 1. In within-run precision study for lithium concentration, coefficient variations (CVs, %) ranged from 1.34 to 2.17 for AAS and from 0.34 to 0.85 for ISE method. In between-run precision study for lithium concentration, CVs ranged from 1.23 to 1.72 for AAS and from 0.61 to 1.38 for ISE method. 2. The correlation study between AAS and ISE method resulted in Y=0.946X+0.137 (N=32, r=0.933, X=AAS, Y=ISE) for serum lithium and Y=1.092X+0.977 (N=28, r=0.943, X=AAS, Y=ISE) for urine lithium. 3. Time-related changes of serum lithium concentration in both AAS and ISE method resulted in peak serum levels about 2 hours after dosing and then rapidly decreased after the peak serum level and finally arrived at nearly initial levels about 9 hours after dosing. 4. The reference range of serum lithium was found as undetectable level for both AAS and ISE method and the reference range of urine lithium to the urine creatinine was 0-0.00014 mmol/mg(mean 0.00002 mmol/mg) for AAS method.

  • PDF

Mechanical and Electrical Reliability of Silver Nanowire Film on Flexible Substrate (유연기판 위에 제작된 Silver Nanowire 필름의 기계 및 전기적 신뢰성 연구)

  • Lee, Yo Seb;Lee, Won Jae;Park, Jin Yeong;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.93-99
    • /
    • 2016
  • In this paper, we investigated the mechanical and electrical reliability of silver nanowire (AgNW) films. In particular, the durability and reliability of AgNW films were studied when the AgNW film was subjected to the bending deformation under current flow. The electrical durability of AgNW was evaluated by observing changes in heat generation and current density occurring in AgNW through voltage and current tests. The AgNW film showed a constant resistance change up to a bending radius of 2 mm and 200,000 cycles in the bending fatigue tests. The over-coating layer has an effect of improving the durability of the AgNW film. In the case of AgNW with the over-coating layer, heat was uniformly dissipated on the surface of AgNW film, whereas in the case of AgNW film without the over-coating layer, heat was generated locally. In the bending test under the current flow, the current density of the AgNW film was continuously decreased up to 52.4%. During bending, the AgNW was deformed due to mechanical deformation such as tensile, bending and sliding of the AgNW, consequently contact resistance of the AgNW was increased, leading to a electrical breakdown of AgNW by Joule heating. It was found that the application of the over-coating layer can improve the electrical and mechanical reliability of the AgNW film.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Highly Efficient 13.56 MHz, 300 Watt Class E Power Transmitter (13.56 MHz, 300 Watt 고효율 Class E 전력 송신기 설계)

  • Jeon, Jeong-Bae;Seo, Min-Cheol;Kim, Hyung-Chul;Kim, Min-Su;Jung, In-Oh;Choi, Jin-Sung;Yang, Youn-Goo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.805-808
    • /
    • 2011
  • This paper presents a design of high-efficiency and high-power class E power transmitter. The transmitter is composed of 300 Watt class E power amplifier and AC-DC converter. The AC-DC converter converts 220 V and 60 Hz AC to a 290 V DC. The generated DC voltage is directly applied to a bias of the class E power amplifier. Because the converter does not have DC-DC converter unit, it has very high conversion efficiency of about 98.03 %. To minimize the loss at the output of the power amplifier, high-Q inductor was implemented and deployed to the output resonant circuit. As a result, the 13.56 MHz class E power amplifier has a high power-added efficiency of 84.2 % at the peak output power of 323.6 W. The overall efficiency of class E power transmitter, including the AC-DC converter, is as high as 82.87 %.

A Study on the Design of Power System for Buoy (등부표 전력 시스템 설계에 관한 연구)

  • Jo, Kwan-Jun;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.35 no.8
    • /
    • pp.631-636
    • /
    • 2011
  • Stable power supply to a light mounted on a navigational buoy is indispensable factor because unstable power can lead to fatal marine accident. Despite the difference lies between onshore and offshore environment, as well as the power output characteristics, the PV(Photovoltaic) power generation system is designed by the independent onshore power generation system standards. Furthermore, the capacity of PV power generation system does not take into account the structural characteristics of the buoy in the sea. Therefore, the faulty design makes battery over-discharge owing to lack of the power generation and the battery can not supply stable power to the light. This paper introduces a design method for a power system of the PV powered buoy. The data has been acquired for 3 months period, which includes PV-generated electricity, power consumption and battery voltage from experimental buoy. Further, a power management features of the buoy has been analyzed based on the acquired data. From the analysis of the acquired data, it was evident that PV power generation system produces different electric power output depend on its installed environment - land and sea. Based on the analytical result, a design criterion has been proposed for the power system in the navigational buoy.

A $2{\times}2$ Microstrip Patch Antenna Array for Moisture Content Measurement of Paddy Rice (산물벼 함수율 측정을 위한 $2{\times}2$ 마이크로스트립 패치 안테나 개발)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.97-106
    • /
    • 2000
  • To develop the grain moisture meter using microwave free space transmission technique, a 10.5GHz microwave signal with the power of 11mW generated by an oscillar with a dielectric resonator is transmitted to an isolator and radiated from a transmitting $2{\times}2$ microstrip patch array antenna into the sample holder filled with the 12 to 26%w.b. of Korean Hwawung paddy rice. the microwave signal, attenuated through the grain with moisture, is collected by a receiving $2{\times}2$ microstrip patch array antenna and detected using a Shottky diode with excellent high frequency characteristic. A pair of light and simple microstrip patch array antenna for measurement of grain moisture content is designed and implemented on atenflon substrate with trleative dielectric constant of 2.6 and thickness of 0.54 by using Ensemble ver. 4.02 software. The aperture of microstrip patch arrays is 41 mm width and 24mm high. The characteristics of microstrip patch antenna such as grain. return loss, and bandwidth are 11.35dBi, -38dB and 0.35GHz($50^{\circ}$ at far-field pattern of E and H plane. The width of the sample holder is large enough to cover the signal between the antennas temperature and bulk density respectively. The calibration model for measurement of grain moisture content is proposed to reduce the effects of fluectuations in bulk density and temperature which give serious errors for the measurements . From the results of regression analysis using the statistically analysis method, the moisture content of grain samples (MC(%)) is expressed in terms of the output voltage(v), temperature (t), and bulk density of samples(${\rho}b$)as follows ;$$MC(%)\;=\;(-3.9838{\times}10^{-8}{\times}v^{3}+8.023{\times}10^{-6}{\times}v^{2}-0.0011{\times}v-0.0004{\times}t+0.1706){\frac{1}{{\rho}b}}{\times}100$ Its determination coefficient, standard error of prediction(SEP) and bias were found to be 0.9855, 0.479%w.b. and -0.0.369 %w.b. respectively between measured and predicted moisture contents of the grain samples.

  • PDF

Actuation Performance of LIPCA and bare PZT at Active Vibration Control of a Cantilever Beam (압전 복합재료 작동기 LIPCA와 단일 PZT의 보 진동 제어 성능 비교)

  • ;Gu, Nam-Seo;Park, Hun-Cheol;Lee, Yeong-Jae;Yun, Gwang-Jun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.60-66
    • /
    • 2006
  • The purpose of this paper is to evaluate potential application of Lightweight Piezo-composite Actuator (LIPCA) to suppress vibrations of structures. The LIPCA, consisting of a piezoelectric layer, a carbon/epoxy layer and glass/epoxy layers, has advantages in terms of high performance, durability and reliability, compared to the bare piezoelectric ceramic (PZT) actuator. We performed two kinds of experiments on static actuation and active vibration suppression to investigate the actuation performances of the LIPCA and the bare PZT. We attached the actuator on one side and a strain gage on the other side of an aluminum beam. In the static actuation test, we evaluated the performance by comparing equivalent actuation moments of the LIPCA and the bare PZT due to the applied voltage. In the active vibration control test, control signals were generated to suppress the vibration of the beam by the PID control algorithm based on the measured strain signals. The performances were estimated based on settling times of the strain responses. It can be concluded that the LIPCA has better actuation performances than the bare PZT in active control of free vibration as well as static actuation.

Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions (자속구속형 초전도 전류제한기의 철심조건에 따른 특성)

  • Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Cho, Guem-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.38-45
    • /
    • 2006
  • The superconducting fault current limiters(SFCLs) provide the effect such as enhancement in power system reliability due to limiting the fault current within a few miliseconds. Among various SFCLs we have developed a flux-lock type SFCL and exploited a special design to effectively reduce the fault current according to properly adjustable magnetic field after the short-circuit test. This SFCL consists of two copper coils wound in parallel on the same iron core and a component using the YBCO thin film connected in series to the secondary copper coil. Meanwhile, operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. To analyze the operational characteristics, we compared closed-loop with open-loop iron core. When the applied voltage was 200[Vrms] in the additive polarity winding, the peak values of the line current the increased up to 30.71[A] in the closed-loop and 32.01[A] in the open-loop iron core, respectively. On the other hand, in the voltages generated at current limiting elements were 220.14[V] in the closed-loop and 142.73[V] in the opal-loop iron core during first-half cycle after fault instant under the same conditions. We confirmed that the open-loop iron core had lower power burden than in the closed-loop iron core. Consequently, we found that the structure of iron core enabled the flux-lock type SFCL at power system to have the flexibility.

Growth of Green Pepper(Capsicum annuum L.) in a Plastic Greenhouse Covered with Anti-dropping Plasma Film (방적성 Plasma 처리 필름으로 피복된 플라스틱온실의 풋고추 생육)

  • Chun, Hee;Kim, Kyung-Je;Kim, Jin-Young;Kim, Hyun-Hwan;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.156-160
    • /
    • 2000
  • The Plasma film treated with a high electric voltage was developed to enhance flow down of condensation drops on inside plastic film. Arch type greenhouse framed with iron pipe of 25mm diameter defand 1.5mm thickness were covered with either the developed plasma film or surfactant film(control). Green pepper seedlings raised for 40 days in plug trays were transplanted at a density of 110cm by 30cm in each greenhouse. The mount of condensational water on film surface, generated by 7$0^{\circ}C$ water bath chimney systems and flew down, was collected and measured. The amount of collected water after 150 minutes was 2.56 mL.100c $m^{-2}$ and 0.94mL.100c $m^{-2}$ , respectively, in the plasma film and surfactant film-covered greenhouses. The amount of condensational water drops attached on the cover at 08:20 a.m. at 60 days filter covering was 0.34mL.100c $m^{02}$ and 0.32mL.100c $m^{-2}$ , respectively, in the plasma film- and surfactant film-covered greenhouses. Solar irradiance transmitted into greenhouse was 2.0% higher in the greenhouse covered with the plasma film tan that in the greenhouse covered with the surfactant film. Air temperature in the plasma film-covered greenhouse was higher than the surfactant film-covered greenhouse by 0.5$^{\circ}C$. However, there was no difference in relative humidity between the two greenhouse. Plant height, leaf area, dry weight and early yield showed no significant differences.s.

  • PDF