Analysis of the Damage Patterns and Metal Structure of 3 Phase Mold Transformers to which Interlayer Short-circuits have Occurred (층간 단락된 3상 몰드변압기의 소손 패턴 및 금속 조직 해석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.86-91
    • /
    • 2010
  • The purpose of this study is to analyze the damage patterns and metal structure of 3 phase mold transformers collected from places where accidents have occurred. Compared to an oil-immersed transformer, a mold transformer has the advantage of requiring a smaller installation area and can be kept clean, while its disadvantages include the fact that abnormal symptoms of an accident are difficult to discover and its repair is impossible. The capacity of the mold transformers collected from places where accidents have occurred was 200kVA with primary voltages being F23,900V, R22,900V, 21,900V, 20,900V, 19,900V, etc., as well as secondary voltages being 380V, 220V, etc. It was found from the analysis on the diffusion of combustion in the damaged mold transformers that fire occurred first inside the U-phase primary winding and that carbonization and heat were diffused to V-phase and W-phase in V-pattern. In addition, from the analysis on the cross-sectional structure of the metal of the melted high voltage winding using a metallurgical microscope, it was found that the boundary surface, voids, and columnar structure were formed when an interlayer short-circuit had occurred Therefore, even though it is not possible to find the cause for the occurrence of an interlayer short-circuit at the inner side of the primary winding, it is thought that, due to the thermal energy generated when the short-circuit occurred, the heat source was diffused to the upper side and outside, causing a secondary accident.

The Susceptibility of Electronic Circuits inside the Cavity by HPEM(High Power Electromagnetics) Environment (금속 함체내부로 입사되는 고출력 전자기 펄스에 대한 전자회로의 민감성 분석)

  • Hwang, Sunl-Mook;Kwon, Hae-Ok;Huh, Chang-Su;Choi, Jin-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1892-1897
    • /
    • 2012
  • Modern electronic circuits are of importance for the function of communication, traffic systems and security systems. An intentional threat to these systems could be of big casualties and economic disasters. This study has examined susceptibility of electronic circuits inside the cavity by HPEM(High Power Electromagnetics). The UWB measurements were done at an anechoic chamber using a RADAN voltage source, which can generate a transient impulse of about 200 kV. The HPEM wave penetrated inside the metal case appeared to the long damped ringwave of pulse length compared with the incident wave. In addition, the resonant frequency generated inside the metal case occurred primarily in the range of 1~3 GHz. The frequency band of 1~3 GHz was influenced on the electronic circuit, which was confirmed by an external antenna and an internal absorber. The electronic circuit was influenced by HPEM infiltrated into the cavity at the 86 kV/m out of the metal cases. Also in case of an absorber the susceptibility of an electronic circuit was smallest among other cases(aperture, antenna). It is considered that absorber has a function absorbing electromagnetic wave infiltrated into the cavity and simultaneously limiting resonance by varying a boundary condition inside the cavity. Based on the results, electronic equipment systems could be applied to protection that has suited system requirements.

Critical Conduction Mode Bridgeless PFC Converter Based on a Digital Control (디지털 제어 기반의 경계점모드 브릿지리스 PFC 컨버터)

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2000-2007
    • /
    • 2016
  • Generally, in order to implement the CRM(Critical Conduction Mode), the analog controller is used rather than a digital controller because the control is simple and uses less power. However, according to the semiconductor technology development and various user needs, digital control system based on a DSP is on the rise. Therefore, in this paper, the CRM bridgeless PFC converter based on a digital control is proposed. It is necessary to detect the inductor current when it reaches zero and peak value, for calculating the on time and off time by using the current information. However, in this paper, the on-time and off-time are calculated by using the proposed algorithm without any current information. If the switching-times are calculated through the steady-state analysis of the converter, they do not reflect transient status such as starting-up. Therefore, the calculated frequency is out of range, and the transient current is generated. In order to solve these problems, limitation method of the on-time and off-time is used, and the limitation values are varied according to the voltage reference. In addition, in steady state, depending on the switching frequency, the inductance is varied because of the resonance between the inductor and the parasitic capacitance of the switching elements. In order to solve the problem, inductance are measured depending on the switching frequency. The measured inductance are used to calculate the switching time for preventing the transient current. Simulation and experimental results are presented to verify the proposed method.

Optimized Capacitor Bank Design for Capacitive Current Test for High Power Laboratory and Analysis with EMTP Simulation (대전력 시험소의 부하시험용 콘덴서 뱅크의 최적 설계 및 EMTP 해석)

  • Ahn, S.H.;Lee, H.C.;Ham, G.H.;Kim, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1220-1223
    • /
    • 1998
  • High Power Laboratory is the facility for building to simulate the various phenomena generated from electric systems of the real world and to test making and breaking capability, switching capability and durability of circuit breaker, switchgear and other electric utilities, moreover, load equipments which contain capacitor bank is installed for studying the diverse effects originated from the constituent of load through entire systems or receiving end. Such factors, abnormal voltage or current, can be serious in electrical systems, especially, in the case caused by capacitive components such as overvoltage or inrushcurrent, the problems may be more fatal to the systems. In this paper, the optimal design of capacitor bank which will be equipped in High Power Laboratory, which is for simulating as closely as the practical phenomena resulted from the capacitive currents, and the verification aided by computer simulations are presented. For this, analysis of the circuit characteristics according to the standards which can be criteria of the capacitive current tests and the test circuit configuration in accordance with the analysis are proposed in prelude. In the body of the paper the optimal design of capacitor bank has been obtained on the basis of all conditions mentioned above and the test circuit configuration with LGIS test requirements. furthermore, analysis and verification for the design are derived by EMTP. finally, evaluation for the capacitor bank design and further study plan are concluded.

  • PDF

Construction of Microbial Fuel Cells Using Thermophilic Microorganisms, Bacillus licheniformis and Bacillus thermoglucosidasius

  • Choi, Young-Jin;Jung, Eun-Kyoung;Park, Hyun-Joo;Paik, Seung R.;Jung, Seun-Ho;Kim, Sung-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.813-818
    • /
    • 2004
  • A systematic study of microbial fuel cells comprised of thermophilic Bacillus licheniformis and Bacillus thermoglucosidasius has been carried out under various operating conditions. Substantial amount of electricity was generated when a redox mediator was used. Being affected by operation temperature, the maximum efficiency was obtained at 50$^{\circ}C$ with an open circuit voltage of ca. 0.7 V. While a small change around the optimum temperature did not make much effect on the cell performance, the rapid decrease in performance was observed above 70$^{\circ}C$. It was noticeable that fuel cell efficiency and discharge pattern strongly depended on the kind of carbon sources used in the initial culture medium. In the case of B. thermoglucosidasius, glucose alone was utilized constitutively as a substrate in the microbial fuel cell irrespective of used carbons sources. When B. licheniformis was cultivated with lactose as a carbon source, best charging characteristics were recorded. Trehalose, in particular, showed 41.2% coulombic efficiency when B. thermoglucosidasius was cultured in a starch-containing medium. Relatively good repetitive operation was possible with B. thermoglucosidasius cells up to 12 cycles using glucose as a carbon source, when they were cultured with lactose as an initial carbon source. This study demonstrates that highly efficient thermophilic microbial fuel cells can be constructed by a pertinent modulation of the operating conditions and by carefully selecting carbon sources used in the initial culture medium.

A Study on the Development of Bleaching efficiency for flex fabrics by Using Ozone Treatment (오존을 이용한 마직물의 표백성 향상에 관한 연구)

  • Lee, Mun-Soo;Song, Kyong-Hun;Kim, Gyoung-A;Song, Bong-Keun;Lee, Rae-Yohn
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • In order to study on the bleaching efficiency of flex fabrics, ozone which has been produced by an ozone generator, has been contacted with flex fabrics in water at various conditions. The equipments used for the ozone reatment of flex fabrics were the ozone generator and a liquor/ozone contactor. For the study of the bleaching efficiency on flex fabrics, the Hunter's whiteness, tensile strength, microscopic properties of the ozone treated flex fabrics were measured. The concentration of generated ozone was increased, as the voltage increase, flow ratio decrease and oxygen amount increase. The bleaching efficiency of ozone treated fabrics was increased with increasing the net concentration of ozone. The whiteness ozone of treated fabrics was found to be best when treated temperature was $0-15^{\circ}C$ and treated time was 20 min. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised.

  • PDF

Automobile Engine Information Display Device Using CAN Communication (캔 통신을 이용한 자동차 엔진 정보 표시장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.203-210
    • /
    • 2019
  • Most cars today use electronic control to control the state of the engine to achieve optimum performance. This study developed a device for maintaining fault diagnosis and optimal vehicle status by displaying the engine information of a car on the screen in real time using can communication. This system displays information generated from the engine to the driver in real time such as engine intake and exhaust temperature, current battery voltage, tire pressure, RPM, DPF collection amount, torque, and horsepower through the OBD2 socket. You can check immediately. It can help you to drive safely by measuring tire pressure and displaying it on the screen, and it provides a mode to set the shift timing to suit your taste. In particular, in the case of diesel engine cars, the problems caused by smoke can adversely affect the performance and environmental pollution. Therefore, the system was developed to display the DPF collection amount on the system screen to prevent environmental pollution and to manage the vehicle efficiently.

A study of decomposition of sulfur oxides(harmful gas) using calcium dihydroxide catalyst by plasma reactions (Ca(OH)2촉매를 이용한 플라즈마 반응에 의한 황산화물(유해가스)의 제거에 관한 연구)

  • Kim, Dayoung;Hwang, Myungwhan;Woo, Insung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.237-246
    • /
    • 2014
  • Researches on the elimination of sulfur and nitrogen oxides with catalysts and absorbents reported many problems related with elimination efficiency and complex devices. In this study, decomposition efficiency of harmful gases was investigated. It was found that the efficiency rate can be increased by moving the harmful gases together with SPCP reactor and the catalysis reactor. Calcium hydroxide($Ca(OH)_2$), CaO, and $TiO_2$ were used as catalysts. Harmful air polluting gases such as $SO_2$ were measured for the analysis of decomposition efficiency, power consumption, and voltage according to changes to the process variables including frequency, concentration, electrode material, thickness of electrode, number of electrode winding, and additives to obtain optimal process conditions and the highest decomposition efficiency. The standard sample was sulfur oxide($SO_2$). Harmful gases were eliminated by moving them through the plasma generated in the SPCP reactor and the $Ca(OH)_2$ catalysis reactor. The elimination rate and products were analyzed with the gas analyzer (Ecom-AC,Germany), FT-IR(Nicolet, Magna-IR560), and GC-(Shimazu). The results of the experiment conducted to decompose and eliminate the harmful gas $SO_2$ with the $Ca(OH)_2$ catalysis reactor and SPCP reactor show 96% decomposition efficiency at the frequency of 10 kHz. The conductivity of the standard gas increased at the frequencies higher than 20 kHz. There was a partial flow of current along the surface. As a result, the decomposition efficiency decreased. The decomposition efficiency of harmful gas $SO_2$ by the $Ca(OH)_2$ catalysis reactor and SPCP reactor was 96.0% under 300 ppm concentration, 10 kHz frequency, and decomposition power of 20 W. It was 4% higher than the application of the SPCP reactor alone. The highest decomposition efficiency, 98.0% was achieved at the concentration of 100 ppm.

Decomposition of Toxic Chemicals in Microemulsion by Electrolytic Oxidation Method (마이크로 에멀젼 상태에서 전기분해법을 이용한 독성물질 분해 연구)

  • Shim, Sung-Hyun;Chun, Byoung-Chul;Chung, Yong-Chan
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.218-223
    • /
    • 2008
  • Decomposition of reactive organic compound dispersed in microemulsion media by hydroxide ions and proton ions generated during electrolysis was tried and the half-lifes for decomposition were compared. Absorbance of p-nitrophenoxide produced from the decomposition of p-nitrophenylacetate (PNPA) was followed to find the rate of decomposition. The applied voltage, temperature, and the amount of substrate were changed to see the effects on the decomposition rate. The advantages of electrolysis in microemulsion system were the high solubilizing capacity of substrate, easy control of decomposition rate, low operation cost, no need for any addition of chemicals, and no byproducts. The mechanism of decomposition and the application to water purification were discussed.

  • PDF

A Study on Electro-optical Characteristics in Three Kinds of Liquid Crystal Display Operating Mode

  • Moon, Hyun-Chan;Bae, Yu-Han;Hwang, Jeoung-Yeon;Seo, Oae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.2
    • /
    • pp.73-77
    • /
    • 2005
  • In this study, we investigated response characteristics of liquid crystal display (LCD) with different operating mode of nematic liquid crystals (NLCs) such as 45 $^{circ} twisted nematic (TN), 67.3 $^{circ} TN and electrical controlled birefringence (ECB) on the rubbed polyimide (PI) surface with side chains. The pretilt angles generated on polyimide surfaces of the three kinds of LCD operating modes were about 12 $^{circ} that was higher than those of conventional TN-LCOs. Also, the Electro-optical (EO) performance of these LCOs showed stable condition. Low transmittance of the 45 $^{circ} TN and 67.3 $^{circ} TN cell on the rubbed PI surface were measured by using low cell gap d. The fast response time in ECB cell among the three kinds of LCD operating modes was achieved. Also, thermal ability of fast 90 $^{circ} TN-LCD was investigated. The threshold voltage and the response time of thermal stressed TN-LCOs showed the same performances on no thermal stressed TN-LCOs. There was little change of value in these TN cells. However, the transmittances of TN-LCOs on the rubbed PI surface decreased while increasing thermal stress time. Therefore, the thermal stability of TN-LCD was decreased by the high thermal stress for the long duration.