• 제목/요약/키워드: generated load

검색결과 1,312건 처리시간 0.031초

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.

화물차 적재 방식에 따른 축 하중을 고려한 타이어 먼지 중 PM10 발생량 평가기법 연구 (Study on the assessment methodology for the PM10 generated from tire-dust considering the axle load of the truck according to the loading method)

  • 이은정;이희관
    • 도시과학
    • /
    • 제11권2호
    • /
    • pp.45-54
    • /
    • 2022
  • Recently, regulations on automobile exhaust gas emission are being strengthened. Accordingly, automobile exhaust gas emissions are expected to decrease and continue to decrease. On the other hand, many countries do not yet consider the emission of non-exhaust air pollutants from automobiles as important. Automobile non-exhaust substances are classified into three categories: tire dust emissions, brake wear emissions, and road scattering dust. In particular, in the case of tire dust, research results exist that pollutant emissions increase as the weight of a vehicle increases. Since the weight of trucks varies according to the load and the load along the axles is also different, it can be expected that the emission of PM10 from the tire dust will be different depending on the loading method. Therefore, this study was conducted on the amount of PM10 generated in tire dust considering the axle load of the truck according to the loading method. However, it was confirmed that the total amount of PM10 was less than that all loads are loaded in the front or rear when the load was evenly distributed in the front and rear of the cargo compartment. In particular, if the load is distributed evenly in the front and back of the cargo compartment and the load in the front part is divided into 2 to 6 and loaded, as the number of divided loading increases the amount of PM10 generated decreases. And when the load is divided into 6 pieces, the total amount of PM10 generated is 0.3952g, the minimum value. If the load is divided into 6 or more and loaded evenly, the total PM10 generated continuously increases and converges to about 0.3964g.

발전영역을 갖은 자동형 brushless 충전발전기에 관한 연구 (The study of self excited type brushless charging generator, it has generated region)

  • 오병인
    • 전기의세계
    • /
    • 제18권4호
    • /
    • pp.7-15
    • /
    • 1969
  • In this method the condenser excite winding has the phase angle of 90 electrical degree, with the load winding in stator. The condenser excite wing is connected with the condenser while the load winding is with the full rectifer. Direct and quardrature axis components of rotating field winding are composed, of balanced two phase winding, and each one of them is connected with half wave rectifiers. Initically, small amount of lead current can be induced at the condenser excite winding by residual magnetism of rotor. The induced lead current forces the rotating field winding to be excited by synchronous alternating magnetic field. The speed electromotive force, there for, induced in rotating field winding shall electro magnetize the rotating field pole by rotating half wave rectifiers. In the case of the charging generator directly coupled with engines at the operation of wide range speed, the generated region, such as vehicles, aircraft, ships etc, is occured. In conclusion, we can take the advantage of, omitting of voltage regurator and current limiter for charging load and reducing the consumption of fuel using the generated region which can be devided in to Impossible generated region, Generated region, and suspension generated region.

  • PDF

팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정 (Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake)

  • 김동우;장미정;한인섭
    • 대한환경공학회지
    • /
    • 제36권5호
    • /
    • pp.367-377
    • /
    • 2014
  • 국내 최대 상수원인 팔당호는 하천형 호소로 분류되며, 팔당호 수질은 외부오염원의 영향이 크다. 이에 본 연구에서는 팔당호 상류지역의 오염원 분포와 오염물질 유출특성을 분석하여 BOD와 TP 관리를 위한 중점관리 오염원을 선정하고자 하였다. 이를 위해 11개 단위유역에 대한 오염원별 발생부하량과 배출부하량을 조사하고, 74개 소하천의 수질 유량 측정결과를 이용하여 유달부하량과 유역면적당 유달부하 밀도를 분석하였다. 오염원별 BOD, TP 발생부하량과 배출부하량, 유달부하량을 분석한 결과, BOD 발생부하량은 축산계가 66.0%로 가장 높은 비율을 차지하였고, BOD 배출부하량은 생활계가 42.7%를 차지하였으며, BOD 유달부하량은 축산계와 생활계가 각각 36.4%, 34.3%를 차지하는 것으로 나타났다. TP 발생부하량과 배출부하량, 유달부하량 모두 축산계에서 가장 높은 비율을 차지하였으며, 각각 82.5%, 44.4%, 46.7%로 나타났다. 또한 BOD 유달부하밀도는 인구밀도가 높은 경안천 유역이 $14.6kg/km^2/d$으로 가장 높았고, TP 유달부하밀도는 가축사육두수가 많은 청미천 유역이 $1.23kg/km^2/d$이 가장 높게 나타났다. 이러한 연구결과를 통해 팔당호 수질개선을 위해서는 생활오수와 가축분뇨를 중심으로 오염원관리가 필요하며 경안천 유역은 생활오수에 대한 관리가 필요하고 남한강 유역, 특히 청미천 유역은 가축분뇨에 대한 관리가 필요한 것으로 판단되었다.

가변진폭하중에서 다축-다점 하중 Counting method를 이용한 피로수명평가 (Fatigue life estimation using the multi-axial multi-point Load Counting method under Variable Amplitude Loading)

  • 이원석;이현우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.913-920
    • /
    • 1996
  • In this study, the counting method for multi-axial and multi-point load states was proposed. Using this counting method, the load spectrum is generated from the service load history which is measured for boom structure of excavator. Loading state for loading points of boom structure is described as a multi-dimensional state space. From this load spectrum, the stress spectrum was generated by FEM analysis using the superposition of the unit load. The cumulated damage at the severe damage point of In nm structure by the failure example is calculated by Palmgren-Miner's rule. As a result of this study, the fatigue life estimation using the multi-axial and multi-point load counting method is useful.

  • PDF

홀로그래피를 이용한 정전집진기 집진판의 진동 특성 연구 (A Study on the Vibration Characteristics of Collecting Plate in the Electrostatic Precipitator Using Holograpy)

  • 나종문;이기백;양장식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권1호
    • /
    • pp.56-66
    • /
    • 1996
  • In this study, the characteristics of generation and propagarion of transient wave induced in the assembly of four collecting plate upon the propagation of waves are analyzed. Also double exposure holographic inteferometry using ruby pulse laser is built in order to investigate the propagation of transient waves generated by impact load. When impact load was applied at edge of connecting band, the vibration of collecting plates was generated from the contact points between collecting plate and band which connects four collecting plates. Waves generated from the lower part and those reflected from the upper part were mixed as time went on and then formed very complex shapes. Also, when impact load was aplied at center of collecting plate, the waves propagating across the convexo-concave plane were reflected partly at curved section. Therefore the vibration amplitude was decreased as the transiet waves were propagated through the convexo-concave plane.

  • PDF

쇄석기의 충격하중 정량화에 대한 연구 (A Study on the Impact Load Quantification of the Jaw Crusher)

  • 홍성주;양해정
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2019
  • Jaw crusher is a device that breaks rock collected from mines or quarries to produce aggregates of the size desired by user. A representative method for measuring load is to measure them by attaching force sensors directly to the part where the load is generated. However, the direct method has many limitations such as high-impact loads generation in equipment or space constraints, sensor capacities and costs. Therefore, Transfer Path Analysis (TPA) was used to indirectly measure impact loads by attaching acceleration sensors. In this study, both direct and TPA methods were used to measure the impact load of Jaw crusher. This study finally quantifies the impact of the load generated by the Jaw crusher using direct method and TPA method, and comparing the impact load measured calculated the derive the error rate.

경남지역 딸기, 토마토, 파프리카 양액재배에 따른 발생부하량 비교 (Comparison of Generated Loads by Hydroponics of Strawberry, Tomato, and Paprika in Gyeongsangnam-do)

  • 조현경;김상민
    • 한국농공학회논문집
    • /
    • 제63권5호
    • /
    • pp.73-81
    • /
    • 2021
  • The objective of this study was to analyze the waste nutrient generation loads from hydroponics for three major crops in Gyeongsangnam-do. Study hydroponic farms were selected for the three major crops such as paprika, strawberry, tomato based on the agricultural statistics data and field investigation. The flow amount and water quality for inflow and outflow of study hydroponic farms were monitored and analyzed on a monthly basis. Monitored samples were analyzed in terms of DO, BOD, T-N, T-P, SS, and EC. The generated load of BOD, T-N, and T-P were calculated from the monitored flow and water quality. The monitoring results showed that the drainage ratio for the circular hydroponic farm was lower than the non-circular hydroponic farm because the outflow from the circular hydroponics were much lower than that from the non-circular. The generated load calculation results showed that the BOD tended to have a smaller value than the TMDLs guideline for land, while T-N and T-P showed higher value than that from the TMDLs guideline. In order to effectively manage the pollutant load discharged from the hydroponics farming complex, it is necessary to manage the non-circulating hydroponics farm. To improve water quality, it is necessary to gradually expand the circulating hydroponics farm through policy and economic support.

비선형 부하의 증감에 따른 고조파 특성 분석 (Analysis on the Harmonics Characteristics Due to Increase & Decrease of Nonlinear Load)

  • 김종겸;이은웅
    • 전기학회논문지P
    • /
    • 제52권3호
    • /
    • pp.100-106
    • /
    • 2003
  • The increasing application of power electronic equipment in industrial field has led to a growing concern for harmonic distortion and the resulting impacts on system equipment and operations. Harmonic currents are generated by the operation of nonlinear loads and equipment on the power system. These are more increased by unbalance voltage of electrical distribution power systems. This paper describes harmonics characteristics generated by varying of nonlinear load at the PCC under the voltage unbalance.

시료 파괴 시 발생하는 SP에 관한 기초 연구 (The basic study about streaming potential generated by specimen fracture)

  • 김종욱;조성준;박삼규;성낙훈;송영수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.291-296
    • /
    • 2007
  • We measured potential waveform of load, displacement, micro electric signal generated by rock and mortar fracture using PXI A/D Converter. The rock type used for measurement was used granite, limestone and sandstone, and mortar specimen. we made measuring equipment of physical properties to confirm basic information of physical properties, measured physical properties of rock engineering, electric resistivity and seismic velocity. Potential waveform system was built using PXI A/D Converter and measured potential waveform of load, displacement, micro-electric signal generated using this during uniaxial compressive test by the specimen finished such test of physical properties. Using the saturated rock and mortar specimen, micro electric signal increased, and It didn't increase a signal in dried rock and mortar specimen according as load and strain rate increases. But signal also increased in saturated or dried specimen in case of sandstone. It was possible to check the close correlation relationship the signal and fracture behavior by a compressive load as the signal of fracture position was increased bigger than the other position. It was also possible to check the correlation relationship between physical properties and micro geo-electric signal.

  • PDF