• Title/Summary/Keyword: generated electricity

Search Result 277, Processing Time 0.027 seconds

Synthesis of Quinoxaline Derivatives at Room Temperature Using Magnetic Material Separated from Coal Fly Ash

  • Dhokte, Aashish O.;Sakhare, Mahadeo A.;Lande, Machhindra K.;Arbad, Balasaheb R.
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.1
    • /
    • pp.73-80
    • /
    • 2013
  • An efficient synthesis of quinoxalines derivatives is described using magnetic material separated from coal fly ash. Coal fly ash is a waste material generated in huge amount by burning of coal for the generation of electricity in thermal power station. It contains $SiO_2$, $Al_2O_3$ and magnetic material in significant amounts, from which magnetic material was separated by using magnetic separation method. These separated magnetic material further characterized by XPS, XRD, EDS, FTIR, SEM, TEM and BET techniques. The merits of present method are mild reaction conditions, and also excellent yields and short reaction times.

Modified Differential Protection for Transformers in Wind Farms

  • George, Sujo P.;Ashok, S
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.78-88
    • /
    • 2018
  • The liberalization of electricity market and environmental concerns are the major driving forces for the development of Distributed Generation (DG). The mode of grid-connected wind power generation is becoming popular and has matured as a reliable DG technology. The voltage generated by the wind generator is stepped up to the higher voltage by the transformers before connecting to the grid. Operating algorithm of the differential relays for transformer protection used in the wind farms need to be modified to take care of the dynamic nature of fault current caused by the intermittent nature of the wind power. An algorithm for the differential relay is proposed in which dual slope characteristics are adjusted with varying fault level situation according to the wind generator in service as well as with the wind speed. A case study conducted for a typical wind farm shows that the proposed method avoids mal-operation of the differential relay in varying wind power conditions.

Unit Commitment for an Uncertain Daily Load Profile

  • Park Jeong-Do
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.16-21
    • /
    • 2005
  • In this study, a new Unit Commitment (UC) algorithm is proposed to consider the uncertainty of a daily load profile. The proposed algorithm calculates the UC results with a lower load level than that generated by the conventional load forecast method and the greater hourly reserve allocation. In case of the worst load forecast, the deviation of the conventional UC solution can be overcome with the proposed method. The proposed method is tested with sample systems, which indicates that the new UC algorithm yields a completely feasible solution even when the worst load forecast is applied. Also, the effects of the uncertain hourly load demand are statistically analyzed, particularly by the consideration of the average over generation and the average under generation. Finally, it is shown that independent power producers participating in electricity spot-markets can establish bidding strategies by means of the statistical analysis. Therefore, it is expected that the proposed method can be used as the basic guideline for establishing bidding strategies under the deregulation power pool.

Capacitor bank assisted Battery fed Boost Converter for self-electricity-generated transportation cart system (자가발전 이동 카트 시스템을 위한 배터리-캐패시터 뱅크를 갖는 부스트 컨버터)

  • Kong, Sung Jae;Yang, Tae Cheol;Kang, Kyung Soo;Roh, Chung Wook
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.130-131
    • /
    • 2017
  • 기존 이동 트레이의 경우 모터를 구동하기 위해 외부 전원장치가 필요하고 지속적인 유지보수가 필요한 문제점이 있다. 이를 해결하기 위해 외부 전원 장치가 아닌 발전기 바퀴를 통해 배터리를 충전하여 3배 이상 승압 가능한 Boost Converter로 모터를 구동한다. 하지만 모터 기동 시 필요한 순간적인 큰 전류를 배터리에서 공급하기 때문에 배터리의 수명이 감소되는 문제점이 있다. 본 논문에서는 3배 이상 승압이 가능하면서 배터리 부담을 줄이는 Super Cap. String을 사용하여 순간적으로 필요한 큰 전류를 공급하는 Boost Converter를 제안한다. 이를 이론적, 실험적 분석을 통해 그 타당성을 검증한다.

  • PDF

Process Design Biogas Plant of the Farm Scale livestock excretions (농가형 축산분뇨 처리를 위한 바이오가스화 공정 설계)

  • Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.128-131
    • /
    • 2010
  • Recently, environmental pollution by livestock excretion is gathering strength as livestock industry is advanced on a large scale. Bio-gas is generated more than about 70 precent if remove impurities in the course of extracting bio-gas to use livestock excretion. In this paper, we developed a device that can use it in heating after extracting bio-gas from livestock excretion collected in livestock farmhouse and can supply electricity by using generator developed in itself. Also, because this system is epoch-making no discharge system to solve smear of existing method, it is expected that we have effects to prevent environmental pollution and get alternation energy and burden on the institution to treat livestock excretion of a pig breeder is solved, if use it.

  • PDF

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.

Protection and Electrostatic Analysis of the Industrial Type Inkjet Plotter using FEM (유한요소법을 이용한 산업용 잉크젯 플로터의 정전기 해석과 대책)

  • Yoon, S.Y.;Choi, G.S.;Kim, Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1496-1499
    • /
    • 2005
  • This paper was represented an electrostatics distribution analysis using FEM(finite element method) with industrial type Inkjet plotter. Here, we know electronic value with each system position by experiment. these were decreased by discharge through earth and electricity shielding. According to industrial development, all fields using chemical instrument and material are generated an electrostatics. Based on these, the big large position of electrostatics was obtained metal base of controller, nonconductor fiber between two rubber roller, head controller by moving roller etc., Therefore these were showed an electrostatics generation source and by rubbing and meager profits electric charge.

  • PDF

A Study on the Estimation Model of Cost of Energy for Wind Turbines (풍력발전기의 에너지 비용 산출에 대한 고찰)

  • Chung, Taeyoung;Moon, Seokjun;Rim, Chaewhan
    • New & Renewable Energy
    • /
    • v.8 no.4
    • /
    • pp.3-12
    • /
    • 2012
  • Large offshore wind farms have actively been developed in order to meet the needs for wind energy since the land-based wind farms have almost been fully developed especially in Europe. The key problem for the construction of offshore wind farms may be on the high cost of energy compared to land-based ones. NREL (National Renewable Energy Laboratory) has developed a spreadsheet-based tool to estimate the cost of wind-generated electricity from both land-based and offshore wind turbines. Component formulas for various kinds and scales of wind turbines were made using available field data. In this paper, this NREL estimation model is introduced and applied to the offshore wind turbines now under designing or in production in Korea, and the result is discussed.

Analysis of Power System Dynamic Security Due to Operation of 345kv CLR (345kv한류리액터 운전에 따른 전력계통 동적안전도 해석)

  • Lee Baek Seok;Kang Dae Eon;Lee Kang Wan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.24-26
    • /
    • 2004
  • The growing demand for electricity has result in a corresponding increase in power generated and transmitted. As the increase in installed capacity of power system, the fault currents of 345kv system will be increased beyond the interrupting duty of the circuit breakers. The current limiting reactors are used to limit the fault current. The paper presents the result of the transient stability and voltage stability due to install 345kV current limiting reactor to suppress the fault currents.

  • PDF

Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater (심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석)

  • JUNG, H.;HWANG, S.W.;LEE, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.