• Title/Summary/Keyword: general interference

Search Result 285, Processing Time 0.037 seconds

Gouging-free Tool-path Generation for Manufacturing Model Propellers (모형 프로펠러 제작을 위한 과절삭이 없는 공구 경로 생성)

  • Kim, Yoo-Chul;Kim, Tae-Wan;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.2 s.152
    • /
    • pp.198-209
    • /
    • 2007
  • In this paper, we present the gouging and collision-free tool-path generation for manufacturing model propellers using the 5-axis NC machine. Because it takes much time to generate tool-paths when we use general purpose CAD/CAM systems, a specific system would be necessary for marine propellers. Overall manufacturing process is composed of two steps: roughcut and finishcut steps. The roughcut is conducted using only 3-axis for efficient machining and the finishcut is done using 5-axis for avoiding collision. The tool-path that might happen to gouging is searched and the tool position is also decided for avoiding interference between the tool and the propeller blades. The present algorithm is applied extensively to the surface piercing propellers. Some results are demonstrated for its validation.

Scheduling Algorithm for Multiuser MIMO-OFDM System (MMSE-SIC 기반 상향링크 다중 사용자 MIMO-OFDM 시스템에서 공정한 스케줄링 기법)

  • Lee, Pan-Hyung;Lee, Jae-Hong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.91-94
    • /
    • 2008
  • 본 논문에서는 준 정적(quasi-static) 레일레이 페이딩(Rayleigh fading) 채널에서 상향링크 다중 사용자 MIMO-OFDM 시스템을 위한 최소평균제곱오차-순차간섭제거(MMSE-SIC: Minimum mean square error-successive interference cancellation) 수신기에 대해 연구한다. 송신 안테나가 하나인 사용자와 수신 안테나가 다수인 기지국에서 MMSE-SIC 수신기를 기반으로 신호를 검출하는 시스템에서는 하나의 부대역 내에서 동시에 전송 가능한 사용자의 수가 기지국에서의 수신안테나 수보다 작아야 하는 제한 조건을 가지고 있다. 따라서 사용자간 공정성을 보장하고 시스템의 효율성을 높이기 위해 낮은 복잡도를 가지는 비례 공정(Proportional fair) 스케줄링 알고리즘을 제안한다. 제안된 비례 공정 스케줄링 알고리즘에서는 부대역 내에서 다중 사용자 채널 행렬을 기반으로 동시에 전송하는 사용자들의 집합을 찾는다. 평균 채널 이득이 사용자마다 다른 환경에서의 모의실험을 통해 제안된 비례 공정 스케줄링 기법의 성능을 알아본다. 제안된 비례 공정 스케줄링 기법은 기존의 공정성을 기반으로 하는 스케줄링 알고리즘보다 더 큰 일반 비례 공정(General proportional fair) 기준과 더 높은 셀 수율(Cell throughput)을 가지는 것을 보이고 있다.

  • PDF

Flight Test of GPS/INS Navigation System for Air Navigation (공중항법을 위한 GPS/INS 비행시험)

  • Yoo, C.S.;Ahn, I.K.;Lim, C.H.;Lee, S.J.;Ahn, I.K.;Nam, G.W.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.10 no.1
    • /
    • pp.35-44
    • /
    • 2002
  • Inertial Navigation System(INS) has been used in the field of air navigation for a long time but is not popular in general aviation due to high price. Recently low-price GPS is available but vulnerable to radio interference. As an alternative on these problems, GPS/INS integrated navigation system has been considered. GPS/INS is capable of implementing navigation with low-price inertial sensors but its accuracy is dependent upon how much drift of INS may be calibrated by using GPS. In order to apply GPS/INS to air navigation, it must be investigated how long drift of INS in case of no GPS aiding will be bounded within requirements for safe flight. From the above motivation, the flight test for GPS/INS navigation system was conducted in order to make sense its performance in air navigation and its result was shown.

  • PDF

Experimental study on the shear thinning effects of viscosity index improver added lubricant by in-situ optical viscometer

  • Jang, Siyonl
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.3
    • /
    • pp.117-124
    • /
    • 2003
  • Elastohydrodynamic lubrication (EHL) film is measured under the condition of viscosity index improver added to base oil. In-situ optical contact method using the interference principle make the measuring resolution of ~5 nm possible and enables the measuring range all over the contact area of up to ~300 $\mu\textrm{m}$ diameter. What is more important to the developed method by the author is that the measurement of EHL film thickness is possible in the range from 100 nm to 2 $\mu\textrm{m}$, which is the regime of worst contact failures in precision machinery. Viscosity index improver (VII) is one of the major additives to the modem multigrade lubricants for the viscosity stability against temperature rise. However, it causes shear thinning effects which make the film thickness lessened very delicately at high shear rate (over $10^5 s^{-1}$) of general EHL contact regime. In order to exactly verify the VIIs performance of viscosity stability at such high shear rate, it is necessary to make the measurement of EHL film thickness down to ~100 nm with fine resolution for the preliminary study of viscosity control. In this work, EHL film thickness of VII added lubricant is measured with the resolution of ~5 nm, which will give very informative design tool for the synthesis of lubricants regarding the matter of load carrying capacity at high shear rate condition.

A Study on RFID Sensors Location Tracking Systems Using Cooperative Spectrum Sensing (협력 스펙트럼 센싱을 이용한 RFID 센서의 위치인식 시스템에 대한 연구)

  • Roh, Chang-Bae;Na, Won-Shik
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.839-844
    • /
    • 2011
  • Various technologies such as infrared light, ultrasonic waves, RFID, GPS, UWB, and signal indicators have been incorporated in the location tracking system. However, such pre-existing systems require location recognition in shadow areas. This study proposes a location tracking system that utilizes Cooperative Spectrum Sensing. Cooperative Spectrum Sensing is not only able to track the location and path of moving objects but also recognize when objects breakaway from the path set by sensors and guide them back. In addition, it has the advantage of being more efficient in terms of frequency usage. It is able to automatically fix power transmission and frequency modulation for transmission cognitive users to an optimum level within the range that does not cause interference for primary users.

Development of a Candidate Equipment for Ozone SRP and its Uncertainty Evaluation (오존 SRP의 제작과 측정 불확도 평가)

  • 정규백;우진춘;이진홍
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.4
    • /
    • pp.313-319
    • /
    • 2001
  • The development of ozone SRP (Standard Reference Photometer) designated as a G-7 project by the Korean Ministry of Environment began 1997 and is now nearly completed. With the completion of the ozone SRP we will not only acquire a qualification to participate in the international ozone calibration system but also enhance calibration credibility of ozone similarly to that of other ambient air pollution monitors. As the ozone SRP uses highly cleaned blank air that can be distinguished from general ozone analyzer, it is possible to reduce errors associated with the determination of ozone via elongation of the absorption length as long as 1 meter In addition, gas chopping method hat been adopted to cut down interference of other substances and time drift. Furthermore, the system has also been modified to minimize the strayed ultra-violet noise along the light path. In this paper, a new method for uncertainty evaluation has been introduced, which is guided by the ISO (International Standard Organization) GUM (Guide to the Expression of Uncertainty in Measurement) through assessments of the uncertainty type B (that was impossible to estimate before) as well as the uncertainty type A (based on statistics).

  • PDF

Defect Inspection of Phase Shift Photo-Mask with Digital Hologram Microscope (디지털 홀로그램 현미경을 이용한 위상차 포토마스크 결함 측정)

  • Cho, Hyung-Jun;Lim, Jin-Woong;Kim, Doo-Cheol;Yu, Young-Hun;Shin, Sang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.303-308
    • /
    • 2007
  • We report here on the application of a digital holographic microscope as a metrology tool for the inspection and the micro-topography reconstruction of different micro-structures of phase shift photo-mask (PSM). The lithography by phase shift photo-mask uses the interference and the pattern of the PSM is not imaged by general optical microscope. The technique allows us to obtain digitally a high-fidelity surface topography description of the phase shift photo-mask with only one hologram image acquisition, allowing us to have relatively simple and compact set-ups able to give quantitative information of PSM.

Evaluation of performance of closed-loop vertical ground heat exchanger by In-situ thermal response test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Kwak, Tae-Hoon;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.229-239
    • /
    • 2010
  • Performing a series of in-situ thermal response tests, the effective thermal conductivity of six vertical closed-loop ground heat exchangers was experimentally evaluated and compared each other, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than that of bentonite grouting, and the efficiency of graphite better performs over silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance.

  • PDF

Prevention of Lung Cancer: Future Perspective with Natural Compounds

  • Brandes, Johann C.;Amin, A.R.M. Ruhul;Khuri, Fadlo;Shin, Dong-Moon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.1
    • /
    • pp.1-15
    • /
    • 2010
  • Lung cancer remains the most common cause of cancer death in the United States and worldwide. About 80~90% of cases are smoking-related and smoking cessation programs are of great importance in reducing lung cancer risk. However, the lifetime risk for lung cancer remains elevated even in ex-smokers. Chemoprevention holds the promise to further reduce this risk and thus to decrease lung cancer incidence and mortality. Over the last decades, most chemoprevention trials for lung cancer have yielded negative outcomes. Population-based studies suggest that high intake of certain foods such as soy, red wine or green vegetables may be associated with decreased cancer risk. Because of these observations and their general safety, a plethora of natural compounds is currently being studied for the chemoprevention of cancer. In this review we discuss promising in vitro and in vivo data of novel natural compounds, their interference with molecular mechanisms responsible for lung cancer development and potential implications for their further preclinical and clinical investigation.

Different Real Time PCR Approaches for the Fine Quantification of SNP's Alleles in DNA Pools: Assays Development, Characterization and Pre-validation

  • Mattarucchi, Elia;Marsoni, Milena;Binelli, Giorgio;Passi, Alberto;Lo Curto, Francesco;Pasquali, Francesco;Porta, Giovanni
    • BMB Reports
    • /
    • v.38 no.5
    • /
    • pp.555-562
    • /
    • 2005
  • Single nucleotide polymorphisms (SNPs) are becoming the most common type of markers used in genetic analysis. In the present report a SNP has been chosen to test the applicability of Real Time PCR to discriminate and quantify SNPs alleles on DNA pools. Amplification Refractory Mutation System (ARMS) and Mismatch Amplification Mutation Assay (MAMA) has been applied. Each assay has been pre-validated testing specificity and performances (linearity, PCR efficiency, interference limit, limit of detection, limit of quantification, precision and accuracy). Both the approaches achieve a precise and accurate estimation of the allele frequencies on pooled DNA samples in the range from 5% to 95% and don't require standard curves or calibrators. The lowest measurement that could be significantly distinguished from the background noise has been determined around the 1% for both the approaches, allowing to extend the range of quantifications from 1% to 99%. Furthermore applicability of Real Time PCR assays for general diagnostic purposes is discussed.