• 제목/요약/키워드: gauge function

검색결과 140건 처리시간 0.029초

손기능과 손의 특성과의 관계 (The Relationships between Hand Function and Characteristics of Hand)

  • 이선명
    • 한국임상보건과학회지
    • /
    • 제3권3호
    • /
    • pp.409-418
    • /
    • 2015
  • Purpose. This study was to investigate the relationship between hand function and characteristics of hand. Methods. Participants were 56 occupational therapy students who studied in M colleges in Gyengsangnam-do, april 20, 2015 from 1 May, and hand circumference and length (vertical, w), the width was measured. A hand grip on the measurement subject was measured by the Grip dynamometer and Pinch gauge. Results. The results was hand length, width, circumference long, broad, thick, and hand strength was a greater correlation emerged. Grip strength was showed a significant correlation to the size and grip strength was also correlated. Conclusion. This study was correlation of length of the hand, a length wide and strength of the finger circumference.

교량 구조물의 정밀 계측 시스템 개발 (Development of Precise Measurement System for Structure Bridge)

  • 박성재;신승목;이채규;김상봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.857-862
    • /
    • 2003
  • In this paper, we concern for development of precise measuement system for civil structure by using one chip microprocessor based on communication system. The datalogger is developed by using 80C196KC microprocessor. It has RF communication modul and data acquisition function for several kinds of sensors such as load cell, tilt-meter, strain gauge, tension meter, themocouple and so on. The data is acquisited by datalogger is sent to a main server which is located at central monitoring office. The server has a function suppervising several data points located at civil structures, it analyzes the data and shows the data graphically. The effectiveness of the developed system is proven through experimental results by an application for the bridge of Nakdong river edge in Busan, Korea.

  • PDF

비선형 탄성이론에 기초한 혈관류 생체재료 실험장치 (Rubber-liked Biomaterial Experimental Setup based on Nonlinear Elasticity Theory)

  • 강태원
    • 한국정밀공학회지
    • /
    • 제27권6호
    • /
    • pp.90-97
    • /
    • 2010
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. Using computer-controlled experimental system, the experiment can acquire data such as inner pressure, axial load, diameter and axial gauge length without contacting the specimen. Rubber-liked material which is similar to passive artery was selected as pseudo-biomaterial. Deformations are measured for pressure-diameter curves. The data were collected and stored online to be used in the feedback control of experimental protocols. Finally, the illustrative data obtained from the experimental system were presented and the system shows that strain invariants are controlled to understand the nonlinear elastic behavior of biomaterial which is involved with strain energy function.

크리깅 방법을 기반으로 한 레이더 강우강도 오차 조정 (The Adjustment of Radar Precipitation Estimation Based on the Kriging Method)

  • 김광호;김민성;이규원;강동환;권병혁
    • 한국지구과학회지
    • /
    • 제34권1호
    • /
    • pp.13-27
    • /
    • 2013
  • 정량적인 강수량 추정은 기상학 수문학적 연구와 활용에 가장 중요한 요소 중 하나이다. 본 논문에서는 정량적 강수량 추정을 위하여 레이더 강우의 지리통계적 오차 구조 함수를 공동크리깅에 적용하여 레이더 강우강도를 조정하였다. 레이더 강우강도의 오차는 공동크리깅의 주변수로서 지상 우량계와 레이더의 강우강도의 차이로 산출되었다. 지상 우량계 강우장은 공동크리깅의 이차변수로서 정규크리깅에 의해 산출되었다. 레이더 강우강도의 오차 분포는 실험적 베리오그램으로 결정된 이론적 베리오그램을 공동크리깅에 적용하여 생성되었고, 레이더 강우강도 조정을 위하여 레이더 강우강도의 오차 분포를 레이더 강우장에 적용하였다. 본 연구의 검증을 위하여 국지적으로 호우가 발생하였던 2009년 7월 6일에서 7일까지의 강우 사례를 선정하였다. 오차가 조정된 1시간 레이더 누적강우량과 지상 우량계 누적강우량의 상관성은 조정 전에 비하여 0.55에서 0.84로 향상되었고, 평균제곱근오차는 7.45에서 3.93 mm로 조정되었다.

Arcus Digma를 이용한 하악 중심위 유도방법에 따른 하악위의 재현성에 관한 비교 연구 (Comparison of the replicability of centric relation registration techniques using Arcus Digma)

  • 임현필;조영은;박상원
    • 구강회복응용과학지
    • /
    • 제25권3호
    • /
    • pp.201-210
    • /
    • 2009
  • 중심위는 교합적, 교정적, 보존적 관점에서 진단과 치료에 중요한 요소이며, 중심위에 대한 정의와 채득방법에 대하여서는 학자들마다 다양하게 주장하고 있다. 중심위를 채득하는 방법에는 여러 가지가 있고 임상적으로 가장 중요한 부분 중 하나가 재현성과 정확성을 확보하는 것이다. 이에 저자는 중심위 채득시 하악 과두의 운동접번축(kinematic axis)을 인식하는 Arcus $Digma^{(R)}$의 EPA test를 이용하여 중심위 채득 방법에 따른 재현성을 비교하였다. 구강 악안면계의 기능이상이 없으며 교합이 정상이고 치아의 교모 및 마모가 심하지 않은 성인 10명를 대상으로 5가지 중심위 채득 방법 (Self-guided method, Bimanual manipulation, Chin-point guidance, Leaf gauge method, Gothic arch tracer)에 따른 중심위의 재현성을 Arcus $Digma^{(R)}$를 이용하여 비교 연구한 결과 다음과 같은 결론을 얻었다. 첫째, 중심위 채득 방법에 따라 하악과두의 위치는 상이한 양상을 나타냈다. 둘째, 재현성은 bimanual manipulation이 가장 높게 나타났으며 다음으로 chin point guidance, Gothic arch tracer, leaf gauge를 이용한 방법 그리고 unguided method 순이었다. 셋째, 임상에서 양손조작법이나 chin-point guidance이 재현성면에서 비교적 매우 훌륭한 방법이라는 것을 미루어 알 수 있다.

SWAT을 이용한 섬진강에서 영산강으로의 유역간 물이동 모델링 (Inter-basin water transfer modeling from Seomjin river to Yeongsan river using SWAT)

  • 김용원;이지완;우소영;김성준
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.57-70
    • /
    • 2020
  • 본 연구는 SWAT(Soil and Water Assessment Tool)을 이용하여 섬진강유역과 영산강유역을 대상으로 유역간 물이동 모델링을 수행하였다. 먼저, 영산강과 섬진강유역에 대해 SWAT 모형을 구축하였고 저수지 운영 매개변수 WURESN(Water Use Reservoir Withdrawn)과 Inlet 기능을 이용하여 섬진강유역의 주암댐에서 영산강유역의 광주천으로의 물이동 모델링을 수행하였다. 섬진강유역의 주암댐과 영산강유역의 마륵 수위관측소의 2005년~2017년까지의 댐 방류량, 저수량 그리고 도수유량 자료를 이용하여 SWAT모형의 검보정을 하였다. 주암댐 검보정결과의 평균 RMSE, NSE, R2는 각각 2.22 mm/day, 0.62, 0.86로 나타났고 마륵 관측소는 각각 1.38 mm/day, 0.69, 0.84로 나타났다. 유역간 물이동에 의한 하류의 영향을 평가하기 위해, 영산강유역내 다기능보 2개(승촌보, 죽산보)와 섬진강유역의 곡성과 구례 수위관측소를 선택하여 검보정을 진행하였다. 승촌보, 죽산보, 곡성 및 구례 관측소의 검보정 결과에 대한 평균 RMSE, NSE, R2는 각각 1.49~2.49 mm/day, 0.45~0.76, 0.81~0.90로 분석되었다.

강우공간상관구조의 변동 특성 (On the Variations of Spatial Correlation Structure of Rainfall)

  • 김경준;유철상
    • 한국수자원학회논문집
    • /
    • 제40권12호
    • /
    • pp.943-956
    • /
    • 2007
  • 강우장의 특성을 정량화하는 여러 통계적 특성치 중에 자주 사용되는 공간상관함수(또는 공간상관도)는 강우의 평가나 설계 그리고 강우장을 모형화하는데 중요하게 사용된다. 그러나 강우의 공간상관 구조는 여러 요인에 의해 많은 변동성을 가지고 있다. 이와 같은 강우의 공간상관구조에 대한 변동특성은 유역을 대표하는 공간상관구조를 결정하는데 문제점으로 작용한다. 따라서 본 연구에서는 이변량 혼합분포를 이용하여 강우를 모형화한 후 정규분포와 대수정규분포를 고려하여 월별, 자료의 시간간격별로 공간상관도를 유도하고 그 변동특성을 파악하였다. 대상유역인 금강유역의 28개 강우관측소의 자료를 이용한 결과 다음과 같은 결론을 얻을 수 있었다. (1) 무강우자료에 대한 영향을 고려한 결과, 세 가지의 경우(Case A, B, C) 중에서 Case A(+,+)의 경우가 #0#에 대한 공간상관함수의 왜곡이 최소가 되기 때문에 가장 적절한 경우이다. (2) 일반적으로 사용되는 정규분포보다는 이론적 그리고 실증적으로 더 적절한 대수정규분포를 사용해야 함이 바람직하다. (3) 월별 공간상관함수 중 지수함수적인 감소경향이 가장 뚜렷한 7월의 경우가 유역을 대표하는 공간상관함수로 적절하다. (4) 자료의 시간해상도별 공간상관도는 다르게 유도되기 때문에 각각에 대한 경우를 고려해야 한다.

Effect of Posterior-Anterior Mobilization of the Thoracic Spine on Pain, Respiratory Function, and Thoracic Circumference in Patients With Chronic Low Back Pain

  • Park, Ju-jung;Chon, Seung-chul
    • 한국전문물리치료학회지
    • /
    • 제25권4호
    • /
    • pp.37-45
    • /
    • 2018
  • Background: Posterior-anterior (PA) vertebral mobilization, a manual therapy technique has been used for relieving pain or stiffness treating in spinal segment for in clinical practice, however evidence to gauge efficacy is yet to be synthesised. Objects: This study aimed to investigate the effect of PA mobilization of the thoracic spine on the respiratory function in patients with low back pain (LBP). Methods: The study participants included 30 patients with chronic LBP. They were randomly allocated to the experimental and control groups. The experimental and control groups received PA mobilization of the T1-T8 level of the thoracic spine and placebo mobilization, respectively. All patients received interventions for 35 minutes a day, five times a week, over 2-week period, respectively. Forced vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$), peak expiratory flow (PEF), forced expiratory flow 25~75% ($FEF_{25{\sim}75%}$), and chest wall expansion were measured before and after the intervention. Statistical analysis was performed using independent t-test and two-way analysis of variance, and Pearson's correlation analysis was used to compare the correlation between respiratory function and chest measurement. Results: The experimental group showed significant improvements in FVC, $FEV_1$, PEF, $FEF_{25{\sim}75%}$ (p<.05), and chest wall expansion (p<.05) compared with the control group. Conclusion: PA mobilization of the upper thoracic spine may be beneficial for improving respiratory function parameters including FVC, $FEV_1$, PEF, $FEF_{25{\sim}75%}$, and chest wall expansion in patients with chronic LBP.

심한 교모증 환자의 완전 구강 회복 (Full Mouth Rehabilitation in Severely Worn Dentition)

  • 정재현;최민호;박영록;김창헌;강동완
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.247-256
    • /
    • 2003
  • The patient had bruxism and epilepsy tendency. Inadequate or unstable posterior support was identified due to severe anterior attrition and decreased occlusal vertical dimension. Prematurities of posterior occlusal and wear facets increased the function of anterior teeth, resulting in severe wear. Wear facets displayed sharply defined peripheries, which are matched on articulated diagnostic casts. Also the patient showed C III malocclusion tendency, and lost some facial contour with drooping corners on the mouth. In this case, the alteration of OVD (Occlusal Vertical Dimention) may provide a biologically compatible adjunct to the treatment such as dentofacial esthetics, improved visual proportion in facial heightand mechanical solutions to the force-management of the masticatory system. The patient requires extensive restorative treatment to regain appropriate function, esthetics and comfort. According to the report by Farhad Fays, the average vertical distance from the maxillary to the mandibular mucolabial reflection in the region of the central incisors is approximately 34mm. However, the vertical distance of this patient was found to be 32mm, which was necessary to add gauge 20-sheets to apply vertical dimension. A removable occlusal overlay splint, which restores OVD to the estimated optimalposition, is the general first trial. The patient was observed periodically for 6 weeks, while appropriate adjustments were made vertical dimension to function. When patient felt comfortable with the splint, the teeth were prepared, and provisional restorations are placed for 3 months. The provisional restoration was fabricated by a diagnostic wax-up. When the patient felt comfortable with the provisional restoration, the final restoration mimics OVD, function, and esthetics that have been developed in the treatment restorations. Restoration of the extremely worn dentition presents a substantial challenge to thedentists. Therefore, careful evaluation of the etiology, history, and factors associated with occlusal vertical dimension should be preceded prior to the appropriate treatment planning.

캐드를 이용한 니트디자인의 생산업체 활용 방안 (A Study on Application Methods of Knit Design for Manufacturers using CAD System)

  • 양경애
    • 한국생활과학회지
    • /
    • 제8권1호
    • /
    • pp.165-178
    • /
    • 1999
  • Knitwears it was only for the innerwear, but which has become more available for sportswear and highly valuable formal-dresses for women's apparel and is set a trend toward high value-added products worldwide. Also the industry connected knitwears is more widely applicative than woven industry and is running on the well founded basement for the small enterprises. This study notes that what problems are caused and which utilities can be expected when we design knitwears by Primavision and Texpia CAD system considered the programs for development of domestic knitwears industry. There are much various benefits for designing knitwears from CAD system as shortening working hours, convenience, accuracy, quality control and productivity. It doesn't depend on designer's technique, sense and experiences, but provides, through building the design accuracy, chance to have a precise communication with buyers to be satisfied with the multiplicity, uniqueness and high-quality resulting from reducing the mistake on the operation. But there are some problems for using CAD design system those are no selections for the form, type and thickness of the yarn. Even though it is knitted by the same gauge, the texture conditions show complete difference if the form and thickness is different with. The gauge control without regarding those ought to be improved and the yarn designing function should be appended like in a tektite design. And the CAD design system can not reflect the variables of operating knitting machine and needle. The CAD design system provides the manufacturers with merits those they can change the colors easily to select which one appeals to the customer and check the effects of producing and modeling on monitor. But, in the each producing progress, there are still problems to reduce the practical steps, so intensive care is required of each part.

  • PDF