• Title/Summary/Keyword: gauge function

Search Result 141, Processing Time 0.03 seconds

The Application of Maturity Method on Whitetopping Construction (성숙도 개념을 이용한 Whitetopping 포장의 현장 적용)

  • Jung, Jong-Suk;Cho, Yoon-Ho;Lee, Kang-Won
    • International Journal of Highway Engineering
    • /
    • v.7 no.1 s.23
    • /
    • pp.83-92
    • /
    • 2005
  • Maturity method is a non-destructive method for estimating in-place concrete strength as a function of time and temperature. The main objective is to use maturity method determining joint sawing and traffic opening time for whitetopping construction in Korea. Another objective is to investigate the influence of air temperature in the correspondence to slab temperature and maturity value. For determining the joint sawing and traffic opening time, thermachron i-button and strain gage were inserted in the fresh concrete in the slab and a maturity value was calculated at desired times. In-place strength was then estimated from a pre-established relationship between maturity values and compressive strength. The results showed that there are significant differences between the estimated strength obtained from maturity curve and in-place concrete strength. The reasons are that the gain of in-place concrete strength was influenced by several factors in the field such as curing conditions, air temperature, and wind speed etc. Also, the results showed that air temperature had significant influence on slab temperature and maturity value The slopes of maturity curves exponentially decrease as air temperature decreases. This means that maturity value sharply dropped as air temperature decreases.

  • PDF

A Case Report of Epiphora after Epicanthoplasty (내안각 췌피교정술 후 발생한 유루)

  • Song, Sun Ho;Yoon, Eul Sik;Dhong, Eun Sang
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.41-44
    • /
    • 2010
  • Purpose: The epicanthus is a specific feature in Asian. Many techniques have been described to eliminate the epicanthal fold: resection of glabellar skin, resection of medial canthal skin, V-Y advancement, V-W technique, modified Z-plasty, multiple Z-plasties, and others. The authors observed postoperative epiphora after correction of epicanthal fold by periciliary skin flap without damaging lacrimal duct. Methods: A 19-year-old woman underwent non-incisional blepharoplasty, septorhinoplasty, and periciliary epicanthoplasty. On her history, she didn't have any symptom of epiphora preoperatively. And there was no specific complaint of epiphora during the postoperative two weeks. However epiphora got worse from one month after the surgery. She was out of this country, so the patient re-visited the clinic on the postoperative six months for this on-going symptom. On an ophthalmologic examination, patient's lacrimal duct and sac was intact but both lacrimal puncta of the patient were covered with a thin membrane. This membrane was punctuated by a 25 gauge needle and dilated with a standard dilator. Results: After ophthalmologic treatment, no recurrence was observed during five weeks of follow-up periods. Conclusion: Both lacrimal puncta of the patient were only covered with membranes. And we could not confirm the direct relationship between periciliary epicanthoplasty and postoperative epiphora. The probable factors will be a predisposing narrowed punctum, post operative peri-punctal edema and decrease in muscular function of orbicularis oculi.

A Method on the Improvement of the Minimum Detection Distance of the Remote Measurement Level Meter (원격 측정 레벨계의 최소 탐지거리 성능 개선 방법)

  • Park, Dongkun;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.535-543
    • /
    • 2018
  • Recently, level meters have been associated with the safety and maintenance of industrial sites and require a wide measurement range. Generally, to ensure the measurement range of the level meter, the measurement environment is improved to reduce the noise or to compensate the distortion of the signal through signal processing. The noise of FMCW (Frequency Modulated Continuous Wave) radar level meter or the distortion of the signal affects the near region characteristics of the level gauge, resulting in a reduction of the minimum detection distance. In this paper, an equalizer filter considering characteristics of window function and bit spectrum is applied to remove the noise in the near region of the level meter to improve the minimum detection distance performance and to improve the measurement reliability in the vicinity of the level meter, which is relatively difficult to detect, we want to improve the detection range.

Effect of Water Temperature on Heat Transfer Characteristic of Spray Cooling on Hot Steel Plate (냉각수온 효과에 따른 고온 강판의 스프레이 냉각 열전달 특성 연구)

  • Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.503-511
    • /
    • 2011
  • Water spray cooling is a significant technology for cooling of materials from high-temperature up to $900^{\circ}C$. The effects of cooling water temperature on spray cooling are mainly provided for hot steel plate cooling applications in this study. The heat flux measurements are introduced by a novel experimental technique that has a function of heat flux gauge in which test block assemblies are used to measure the heat flux distribution on the surface. The spray is produced by a fullcone nozzle and experiments are performed at fixed water impact density of G and fixed nozzle-totarget spacing. The results show that effects of water temperature on forced boiling heat transfer characteristics are presented for five different water temperatures between 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided to a benchmark data for the actual spray cooling of hot steel plate cooling applications.

An Effect of Aging and Thermocycling on the Tensile Strength of Restorative Composite Resins (시효와 열순환 처리가 수복용 복합레진의 인장강도에 미치는 영향)

  • Lee, Mi-Jeong;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study was to evaluate effect of aging and thermocycling on the tensile strength of restorative composite resins. Eight commercially available light-cured restorative composites (Heliomolar: HM, Palfique Estelite: PE, Spectrum: ST, UniFil-F: UF, Z100: ZH, Clearfil AP-X: CA, P60: PS, and Palfique Toughwell: PT) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5 mm in gauge length and 2 mm in thickness. All samples were stored in distilled water at $37^{\circ}C$ for 100 days. Every 10 days, specimens were thermocycled for 1,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Tensile testing was carried out at a crosshead speed of 0.5 mm/min and fracture surfaces were observed with a scanning electron microscope. The results obtained were summarized as follows; 1. The strength degradation of thermocycled group was severer than that of the aged group (P<0.01). 2. The tensile strength of the CA and ST groups were significantly higher than that of other groups after thermocycling treatment (P<0.05). 3. Fracture surfaces showed that the composite resin failure developed along the matrix and the filler/resin interface region.

Comparison of Accuracy of Implant Torque Controllers (수종의 임플란트 토크 조절기의 정확성 비교)

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.157-168
    • /
    • 2008
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

Effect of different lateral occlusion schemes on peri-implant strain: A laboratory study

  • Lo, Jennifer;Abduo, Jaafar;Palamara, Joseph
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • PURPOSE. This study aims to investigate the effects of four different lateral occlusion schemes and different excursions on peri-implant strains of a maxillary canine implant. MATERIALS AND METHODS. Four metal crowns with different occlusion schemes were attached to an implant in the maxillary canine region of a resin model. The included schemes were canine-guided (CG) occlusion, group function (GF) occlusion, long centric (LC) occlusion, and implant-protected (IP) occlusion. Each crown was loaded in three sites that correspond to maximal intercuspation (MI), 1 mm excursion, and 2 mm excursion. A load of 140 N was applied on each site and was repeated 10 times. The peri-implant strain was recorded by a rosette strain gauge that was attached on the resin model buccal to the implant. For each loading condition, the maximum shear strain value was calculated. RESULTS. The different schemes and excursive positions had impact on the peri-implant strains. At MI and 1 mm positions, the GF had the least strains, followed by IP, CG, and LC. At 2 mm, the least strains were associated with GF, followed by CG, LC, and IP. However, regardless of the occlusion scheme, as the excursion increases, a linear increase of peri-implant strains was detected. CONCLUSION. The peri-implant strain is susceptible to occlusal factors. The eccentric location appears to be more influential on peri-implant strains than the occlusion scheme. Therefore, adopting an occlusion scheme that can reduce the occurrence of occlusal contacts laterally may be beneficial in reducing peri-implant strains.

A Study on the Development of Dance Sportswear with Cool-touch Function (냉감 기능성 댄스스포츠 웨어 개발에 관한 연구)

  • Jun, Mi-Hwa;Jang, Jeong-Ah;Koo, Young-Seok
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.66-75
    • /
    • 2020
  • This study helps develop cool-touch functional dance sportswear. We suggest a draft design for dance sportswear that chooses appropriate cool-touch functional materials based on an investigation of the changes of body surface temperature before and after exercise, the physical properties of cool-touch materials on the market, and the preference for cooling tools. The results are as follows. First, cool-touch functional sportswear products on the market utilize materials such as PCM, Delta fabric, high gauge fabric, and ice chips as well as incorporate functions such as UV block and eyelets for enhanced breathability. Polyester and polyurethane fibers are mainly used for cool-touch functional sportswear. Second, the neck area showed the highest surface temperatures (32.7℃ and 32.1℃) before and after exercise. Body surface temperatures measured after exercise were also lower than temperatures measured before exercise when wearing dance sportswear. Third, as for the physical properties of cool-touch materials, material 1 showed amaximum drying speed (130 min), material 3 the best moisture absorption speed (122 × 132 min), and material 4 the best thermal conductivity (0.013 7 w/m·K). Fourth, a draft design for a cool-touch functional dance sportswear was suggested, including a neckband made of removable soft PVC material on the neck area and applying material 4 in F1, B4, S2 and lower arm areas and material 1 in the armpit area. Deodorant tape was also attached to the armpit area for added comfort and antibacterial deodorant effect.

Estimation of Rail Irregularities by using Acceleration values (가속도 값을 이용한 궤도 불규칙도 검측)

  • Kim, Young-Mo;Park, Chan-Kyoung;Choi, Sung-Hoon;Kim, Sang-Soo;Park, Choon-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2173-2178
    • /
    • 2008
  • Railroad is the major factor of vibration source in railway vehicles, and it must carefully maintained the original condition to secure the safety and good ride comfort of passenger. Measuring the condition of rail irregularities such as surface, alignment, gauge, twist and cant etc is required to maintain the good performance of railroad. Currently, the various rail irregularity measurement systems(EM120, ROGER1000K and the Total Rail Irregularity Measurement system of Korea High Speed Train) are operated in Korea to estimate the rail irregularity. It is hard to verify the correlation of one rail irregularity data of a measurement system with the other, because they have been adopted different rail irregularity estimation methods. The best method securing the reliability of the irregularity data is the direct confirmation on the ground where the measurement system had detected as a fault section, but it is impossible to apply all sections simultaneously due to limitation of time, labor, cost and equipments. There is a method to secure the reliability of the data by using acceleration values. Rail irregularities, the major factor of vibration in railway vehicle, are transmitted to the vehicle acceleration through masses, springs, dampers and joints as the system dynamic formation. In this study, Transition Function has been adopted by using the rail irregularity and the acceleration value regarding as input & output parameters respectively. It has been verified by comparing the analyzed results with real measured irregularity data from the Total Rail Irregularity Measurement system of Korea High Speed Train. Also various methods has been accomplished to verify the correlation between rail irregularities and acceleration values.

  • PDF

Design of U-healthcare System for Real-time Blood Pressure Monitoring (실시간 혈압 모니터링 u-헬스케어 시스템의 설계)

  • Cho, Byung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.161-168
    • /
    • 2018
  • High blood pressure is main today's adult disease and existing blood pressure gauge is not possible for real-time blood pressure measurement and remote monitoring. But real-time blood pressure monitoring u-healthcare system makes effect health management. In my paper, for monitoring real-time blood pressure, an architecture of real-time blood pressure monitoring system which consisted of wrist type-blood pressure measurement, smart-phone and u-healthcare server is presented. And the analog circuit architecture which is major core function for pulse wave detection and digital hardware architecture for wrist type-blood pressure measurement is presented. Also for software development to operate this hardware system, UML analysis method and flowcharts and screen design for this software design are showed. Therefore such design method in my paper is expected to be useful for real-time blood pressure monitoring u-healthcare system implementation.