• Title/Summary/Keyword: gating

Search Result 364, Processing Time 0.022 seconds

Comparison and Evaluation of the Effectiveness between Respiratory Gating Method Applying The Flow Mode and Additional Gated Method in PET/CT Scanning. (PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가)

  • Jang, Donghoon;Kim, Kyunghun;Lee, Jinhyung;Cho, Hyunduk;Park, Sohyun;Park, Youngjae;Lee, Inwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Purpose The present study aimed at assessing the effectiveness of the respiratory gating method used in the flow mode and additional localized respiratory-gated imaging, which differs from the step and go method. Materials and Methods Respiratory gated imaging was performed in the flow mode to twenty patients with lung cancer (10 patients with stable signals and 10 patients with unstable signals), who underwent PET/CT scanning of the torso using Biograph mCT Flow PET/CT at Bundang Seoul University Hospital from June 2016 to September 2016. Additional images of the lungs were obtained by using the respiratory gating method. SUVmax, SUVmean, and Tumor Volume ($cm^3$) of non-gating images, gating images, and additional lung gating images were found with Syngo,bia (Siemens, Germany). A paired t-test was performed with GraphPad Prism6, and changes in the width of the amplitude range were compared between the two types of gating images. Results The following results were obtained from all patients when the respiratory gating method was applied: $SUV_{max}=9.43{\pm}3.93$, $SUV_{mean}=1.77{\pm}0.89$, and $Tumor\;Volume=4.17{\pm}2.41$ for the non-gating images, $SUV_{max}=10.08{\pm}4.07$, $SUV_{mean}=1.75{\pm}0.81$, and $Tumor\;Volume=3.56{\pm}2.11$ for the gating images, and $SUV_{max}=10.86{\pm}4.36$, $SUV_{mean}=1.77{\pm}0.85$, $Tumor\;Volume=3.36{\pm}1.98$ for the additional lung gating images. No statistically significant difference in the values of $SUV_{mean}$ was found between the non-gating and gating images, and between the gating and lung gating images (P>0.05). A significant difference in the values of $SUV_{max}$ and Tumor Volume were found between the aforementioned groups (P<0.05). The width of the amplitude range was smaller for lung gating images than gating images for 12 from 20 patients (3 patients with stable signals, 9 patients with unstable signals). Conclusion In PET/CT scanning using the respiratory gating method in the flow mode, any lesion movements caused by respiration were adjusted; therefore, more accurate measurements of $SUV_{max}$, and Tumor Volume could be obtained from the gating images than the non-gating images in this study. In addition, the width of the amplitude range decreased according to the stability of respiration to a more significant degree in the additional lung gating images than the gating images. We found that gating images provide information that is more useful for diagnosis than the one provided by non-gating images. For patients with irregular signals, it may be helpful to perform localized scanning additionally if time allows.

  • PDF

"You can't help but Like it": An Investigation of Mandatory Endorsement Solicitation and Gating Practices in Online Social Networks

  • Church, E. Mitchell;Passarello, Samantha
    • Asia pacific journal of information systems
    • /
    • v.26 no.1
    • /
    • pp.124-142
    • /
    • 2016
  • Companies operating in social network platforms continue to improve and expand their marketing techniques. This study examines the practice of "gating", which involves virtual barriers between social network users and company content. Gates demand mandatory user endorsements, in the form of a Facebook "Likes", Twitter "retweets" etc., to gain access to company content, such as coupons and rewards,. Gating practices demand a mandatory endorsement before any content consumption takes place. Thus, while user endorsements are assumed to arise voluntarily from trusted known sources, gating practices would appear to violate this assumption. However, whether this violation lessens the effectiveness of gating practices still requires empirical validation. We investigate this question through the use of a unique panel data set that includes data on "like" endorsements obtained from a number of real-world Facebook business pages. Results of the study show that gating practices are effective for endorsement solicitation; however, gates may interfere with more traditional marketing activities.

Self-Power Gating Technique For Low Power Asynchronous Circuit

  • Mai, Kim-Ngan Thi;Vo, Huan Minh
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.548-557
    • /
    • 2018
  • In this paper, Asynchronous Self-Power Gating technique (ASPG) is used to reduce consumption power in asynchronous digital watch application. The power gating control signal is automatically generated by internal system operation characteristics instead of using replica circuit delay or four-phase handshaking protocol. Isolation cell is designed to insert it between power gating domain and normal operation domain. By using self-power gating circuit, asynchronous digital watch application consumes very low power and maintains data during sleep mode. The comparison results show the proposed ASPG technique saves leakage power up to 40.47% and delay time is reduced to 71% compared to the conventional circuit.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

The study on low power design of 8-bit Micro-processor with Clock-Gating (Clock-gating 을 고려한 저전력 8-bit 마이크로프로세서 설계에 관한 연구)

  • Jeon, Jong-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.3
    • /
    • pp.163-167
    • /
    • 2007
  • In this paper, to design 8 bit RISC Microprocessor, a method of Clock Gating to reduce electric power consumption is proposed. In order to examine the priority, the comparison results of between a 8 bit Microprocessor which is not considered Low Power consumption and which is considered Low Power consumption using a methods of Clock Gating are represented. Within the a few periods, the results of comparing with a Microprocessor not considered the utilization of Clock Gating shows that the reduction of dynamic dissipation is minimized up to 21.56%.

  • PDF

Robust Placement Method for IR Drop in Power Gating Design (파워 게이팅 설계에서 IR Drop에 견고한 셀 배치 방법)

  • Kwon, Seok Il;Han, Tae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.55-66
    • /
    • 2016
  • Power gating is one of effective techniques for reducing leakage current in semiconductor chip. However, power gating cell (PGC) which is used to switch the power source causes performance degradation and the associated reliability problem by increasing IR drop. However, the newly raised problem caused by different scaling properties between gates and metal wires demands additional considerations in power gating design. In this paper, we propose a robust cell placement based power gating design method for reducing the area for power gating cell and metal routing thus to meet IR drop requirement. Experimental results by applying the proposed techniques on the application processor for smartphone fabricated in 28nm CMOS process show that power gating cell area is reduced by 16.16% and maximum IR drop value is also decreased by 8.49% compared to existing power gating cell placement techniques.

A study on the computed aided gating design in gray cast iron (컴퓨터를 이용한 회주철의 탕구방안 설계에 관한 연구)

  • Choi, Jeong-Kil;Kim, Dong-Ok
    • Journal of Korea Foundry Society
    • /
    • v.6 no.1
    • /
    • pp.27-35
    • /
    • 1986
  • The gating design of gray cast iron was programmed in a Personal computer. By this program, casting test was done. The results obtained are as follows. 1. Gating design that can calculate the velocity of metal flow and size in each gate section by knowing the loss coefficient caused by friction loss and bend loss was programmed. 2. In the test casting, the gating ratio was changed into 1.1:1.3:1, 1:2:2, 1:4:4. And sound casting, free of sand washing defect, was obtained at the velocity of 35.5cm/sec in ingate.

  • PDF

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.

Design and FPGA Implementation of FBMC Transmitter by using Clock Gating Technique based QAM, Inverse FFT and Filter Bank for Low Power and High Speed Applications

  • Sivakumar, M.;Omkumar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2479-2484
    • /
    • 2018
  • The filter bank multicarrier modulation (FBMC) technique is one of multicarrier modulation technique (MCM), which is mainly used to improve channel capacity of cognitive radio (CR) network and frequency spectrum access technique. The existing FBMC System contains serial to parallel converter, normal QAM modulation, Radix2 inverse FFT, parallel to serial converter and poly phase filter. It needs high area, delay and power consumption. To further reduce the area, delay and power of FBMC structure, a new clock gating technique is applied in the QAM modulation, radix2 multipath delay commutator (R2MDC) based inverse FFT and unified addition and subtraction (UAS) based FIR filter with parallel asynchronous self time adder (PASTA). The clock gating technique is mainly used to reduce the unwanted clock switching activity. The clock gating is nothing but clock signal of flip-flops is controlled by gate (i.e.) AND gate. Hence speed is high and power consumption is low. The comparison between existing QAM and proposed QAM with clock gating technique is carried out to analyze the results. Conversely, the proposed inverse R2MDC FFT with clock gating technique is compared with the existing radix2 inverse FFT. Also the comparison between existing poly phase filter and proposed UAS based FIR filter with PASTA adder is carried out to analyze the performance, area and power consumption individually. The proposed FBMC with clock gating technique offers low power and high speed than the existing FBMC structures.

Consideration of the Accuracy by Variation of Respiration in Real-time Position Management Respiratory Gating System (호흡동조 방사선치료에 사용되고 있는 RPM (Real-time Position Management) Respiratory Gating System의 호흡변화에 따른 정확성에 대한 고찰)

  • Na, Jun Young;Kang, Tae Young;Baek, Geum Mun;Kwon, Gyeong Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Purpose: Respiratory Gated Radiation Therapy (RGRT) has been carried out using RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, varian, USA) in Asan Medical Center. This study was to analyze and evaluate the accuracy of Respiratory Gated Radiation Therapy (RGRT) according to variation of respiration. Materials and Methods: Making variation of respiration using Motion Phantom:QUASAR Programmable Respiratory Motion Phantom (Moudus Medical Device Inc. CANADA) able to adjust respiration pattern randomly was varying period, amplitude and baseline by analyze 50 patient's respiration of lung and liver cancer. One of the variations of respiration is baseline shift gradually downward per 0.01 cm, 0.03 cm, 0.05 cm. The other variation of respiration is baseline shift accidently downward per 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm. Experiments were performed in the same way that is used RPM Respiratory Gating System (phase gating, usually 30~70% gating) in Asan Medical Center. Results: It was all exposed radiation under one of the conditions of baseline shift gradually downward per 0.01 cm, 0.03 cm, 0.05 cm. Under the other condition of baseline shift accidently downward per 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm equally radiation was exposed. Conclusion: The variations of baseline shifts didn't accurately reflect on phase gating in RPM Respiratory Gating System. This inexactitude makes serious uncertainty in Respiratory Gated Radiation Therapy. So, Must be stabilized breathing of patient before conducting Respiratory Gated Radiation Therapy. also must be monitored breathing of patient in the middle of treatment. If you observe considerable changes of breathing when conducting Respiratory Gated Radiation Therapy. Stopping treatment immediately and then must be need to recheck treatment site using fluoroscopy. If patient's respiration rechecked using fluoroscopy restabilize, it is possible to restart Respiratory Gated Radiation Therapy.

  • PDF