• Title/Summary/Keyword: gaseous standard

Search Result 59, Processing Time 0.026 seconds

Chromium Poisoning of Neodymium Nickelate (Nd2NiO4) Cathodes for Solid Oxide Fuel Cells

  • Lee, Kyoung Jin;Chung, Jae Hun;Lee, Min Jin;Hwang, Hae Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.2
    • /
    • pp.160-166
    • /
    • 2019
  • In this study, we investigated the long-term stability of Nd2NiO4 solid oxide fuel cell (SOFC) cathodes to evaluate their chromium poisoning tolerance. Symmetrical cells consisting of Nd2NiO4 electrodes and a yttria-stabilized zirconia electrolyte were fabricated and the cell potential and polarization resistance were measured at 850 ℃ in the presence of gaseous chromium species for 800 h. Up to 500 h of operation, the cell potential remained constant at 500 mA/㎠. However, it increased slightly over the operation duration of 550-800 h. No appreciable increase was observed in the polarization resistance of the Nd2NiO4 cathode during the entire operation of 800 h. Physicochemical examinations revealed that the gaseous chromium species did not form chromium-related contamination not only in the Nd2NiO4 cathode but also at the cathode/electrolyte interface. The results demonstrated that Nd2NiO4 is resistant to chromium poisoning, and hence is a potential alternative to standard perovskite cathodes.

Highly Sensitive Colorimetric Formaldehyde Gas Sensors using Nylon Sheet and Dye (나일론 시트와 염료를 이용한 고감도 색변환 포름알데히드 가스 센서)

  • Jung, Suenghwa;Cho, Yeong Beom;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.420-426
    • /
    • 2017
  • A colorimetric sensor was investigated to achieve a low-cost warning device for harmful gaseous formaldehyde (HCHO). The sensor is based on selective reactions between hydroxylamine sulfate and HCHO, leading to the production of sulfuric acid. The produced acid results in color-changing response through the acid-base reaction with dye molecules impregnated on a solid membrane substrate. For attaining this purpose, sensors were fabricated by drop-casting a dye solution prepared using different pH indicators on various commercially available polymer sheets, and their colorimetric responses were evaluated in terms of sensitivity and reliability. The colorimetric sensor using bromophenol blue (BPB) and nylon sheet was found to exhibit the best performance in HCHO detection. An initial bluish green of a sensor was changed to yellow when exposed to gaseous formaldehyde. The color change was recorded using an office scanner and further analyzed in term of RGB distance for quantifying sensor's response at different HCHO(g) concentrations. It exhibited a recognizable colorimetric response even at 50 ppb, being lower than WHO's standard of 80 ppb. In addition, the sensor was found to have quite good selectivity in HCHO detection under the presence of common volatile organic compounds such as ethanol, toluene, and hexane.

A Numerical Study on the Short-term Dispersion of Toxic Gaseous and Solid Pollutant in an Open Atmosphere : Chemical Species, Temperature, Relative Velocity (고-기상 독성오염물질 단기 대기확산에 관한 수치해석적 연구 : 화학종, 온도, 상대속도)

  • 나혜령;이은주;장동순;서영태
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.68-80
    • /
    • 1995
  • A series of parametric calculations have been performed in order to investigate the short-term and short-range plume and puff behavior of toxic gaseous and solid pollutant dispersion in an open atmosphere. The simulation is made by the use of the computer program developed by this laboratory, in which a control-volume based finite-difference method is used together with the SIMPLEC algorithm for the resolution of the pressure-velocity coupling appeared In Wavier-Stokes equation. The Reynolds stresses are solved by the standard two-equation k-$\varepsilon$ model modified for buoyancy together with the RNG(Renormalization Group) k-$\varepsilon$ model. The major parameters considered in this calculation are pollutant gas density and temperature, the relative velocity of pollutants to that of the surrounding atmospheric air, and particulate size and density together with the height released. The flow field is typically characterized by the formation of a strong recirculation region for the case of the low density gases such as $CH_4$ and air due to the strong buoyancy, while the flow is simply declining pattern toward the downstream ground for the case of heavy molecule like the $CH_2C1_2$and $CCl_4$, even for the high temperature, $200^{\circ}C$. The effect of gas temperature and velocity on the flow field together with the particle trajectory are presented and discussed in detail. In general, the results are physically acceptable and consistent.

  • PDF

The Structure of Axisymmeric Turbulent Diffusion Flame(II) (재순환 영역이 있는 축대칭 난류 확산화염의 구조 (II))

  • 이병무;신현동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.70-77
    • /
    • 1986
  • Turbulent mixing field with recirculating flow which is formed by injecting gaseous fuel on the main air stream is solved numerically by a finite difference method. The turbulence model for obtaining transport properties was k-.epsilon. model, which was obtained from turbulent kinetic energy and its dissipation rate. Considering the effects of streamline curvature, modified k-.epsilon model was used. Generally, Modified k-.epsilon. model makes better predictions than standard model, and from this result, it is recognized that standard model has deficiency when applied to turbulent recirculating flows, and that modified k-.epsilon. model takes into account of streamline curvature effects properly. Meanwhile, A more study will be necessary to find the reason why large differences between predicted and experimental turbulent kinetic energy exist.

Radiological Dose Analysis to the Public Resulting from the Operation of Daedeok Nuclear Facilities (대덕부지 원자력관련시설 운영에 따른 주민피폭선량 현황분석)

  • Jeong, Hae Sun;Kim, Eun Han;Jeong, Hyo Joon;Han, Moon Hee;Park, Mi Sun;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.38-45
    • /
    • 2014
  • This paper describes the results of assessment of radiological dose resulting from operation of the Daedeok nuclear facilities including the HANARO research reactor, which has been performed to assure whether or not to comply with the regulation standards of the radioactive effluents releases. Based on the meteorological data and the radiation source term, the maximum individual doses were evaluated from 2010 to 2012. The atmospheric dispersion and the deposition factors of gaseous effluents were calculated using the XOQDOQ computer code. ENDOS-G and ENDOS-L code systems were also used for maximum individual dose calculation from gaseous and liquid effluents, respectively. The results were compared with the regulation standards for the radioactive effluents presented by the Nuclear Safety and Security Commission (NSSC). The effective doses and the thyroid doses of the maximum individual were calculated at the maximum exposed point in the Daedeok site, and contributions of exposure pathways to the radiological doses resulting from gaseous and liquid radioactive effluents were evaluated at each facility of the Daedeok site. As a result, the maximum exposed age was analysed to be the child group, and the operation of HANARO research reactor had a major effect more than 90% on the individual doses. The main exposure pathways for gaseous radioactive effluent were from ingestion and inhalation. The effective doses and the thyroid doses were considerably influenced by tritium and iodine, respectively. The gaseous radioactive effluents contributed more than 90% on the total doses, whereas the contributions of the liquid radioactive effluents were relatively low. Consequently, the maximum individual dose due to radioactive effluents from the nuclear facilities within the Daedeok site were less than 3% of the regulation standard over 3 years; therefore, it can be concluded that radioactive effluents from the nuclear facilities were well managed, with the radiation-induced health detriment for residents around the site being negligible.

Extraction of the atmospheric path radiance in relation to retrieval of ocean color information from the TM and SeaWiFS imageries

  • Ahn, Yu-Hwan;Shanmugam, P.
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.241-246
    • /
    • 2004
  • The ocean signal that reaches the detector of an imaging system after multiple interactions with the atmospheric molecules and aerosols was retrieved from the total signal recorded at the top of the atmosphere (TOA). A simple method referred to as 'Path Extraction' applied to the Landsat-TM ocean imagery of turbid coastal water was compared with the conventional dark-pixel subtraction technique. The shape of the path-extracted water-leaving radiance spectrum resembled the radiance spectrum measured in-situ. The path-extraction was also extended to the SeaWiFS ocean color imagery and compared with the standard SeaWiFS atmospheric correction algorithm, which relays on the assumption of zero water leaving radiance at the two NIR wavebands (765 and 865nm). The path-extracted water-leaving radiance was good agreement with the measured radiance spectrum. In contrast, the standard SeaWiFS atmospheric correction algorithm led to essential underestimation of the water-leaving radiance in the blue-green part of the spectrum. The reason is that the assumption of zero water-leaving radiance at 755 and 865nm fails due to backscattering by suspended mineral particles. Therefore, the near infrared channels 765 and 865nm used fur deriving the aerosol information are no longer valid for turbid coastal waters. The path-extraction is identified as a simple and efficient method of extracting the path radiance largely introduced due to light interaction through the complex atmosphere carried several aerosol and gaseous components and at the air-sea interface.interface.

  • PDF

A Study on Gaseous Effluents from BMRR (Brookhaven 醫學硏究用 原子爐에서의 氣體噴出物에 관한 硏究)

  • Hwang, Sun-Tae;Park, Tae-Soon;Hah, Suck-Ho;Choi, Sung-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 1988
  • Brookhaven 의학연구용 원자로에서 방출되는 기체분출물에 관하여 연구 되었다. 모든 기체시료는 $\gamma$-선 분광계측에 의하여 분석되었다. 시료 중에 존재하는 것으로 확인된 핵종으로서, $^{82}Cl(T_{1/2}$ = 35.30 시간) 이 가장 뚜렷하였다. 그 외의 확인된 핵종은 $^{38}Cl(T_{1/2}$ = 37.24분), $^{41}Ar(T_{1/2}$ = 1.82시간), $^{106}Rh(T_{1/2}$ = 29.80묘), $^{133}Te(T_{1/2}$ = 12.45분)이었다. 3MW 원자로 출력에서 pre-filter bank를 통과한 기체분출물 중에서 $$^{41}Ar$의 농도는 2.436Bq/cc로 계산됨으로써 $^{41}Ar$의 방사능 방출율은 8.51 ${\times}10^9$Bq/MW - h로 산정되었다. filter bank의 방사능 원거효율(%)은 $^{38}Cl$의 경우 97.84%, $^{41}Ar$은 14.15%, ^{82}Br$은 98.70% 그리고 $^{106}Rh$은 98.81% 각각 산정되었다. 한편, charcoal trap과 millipore filter 에서 확인된 기타 핵종들로서 $^{24}Na$, $^{72}Ga$, $^{92}Sr$, $^{97}Zr$, $^{132}I$, $^{133}Te$, $^{141}Ce$, $^{153}Sm$$^{154}Pm$은 filter bank에 의해서 완전히 제거되었다.

  • PDF

Study on the Regional Deposition of Smoke Particles in Human Respiratory Tract under the Variation of Fire and Breathing Conditions (화재 및 호흡조건 변화에 따른 연기입자의 인체 호흡기 내 영역별 침착량 분석)

  • Goo, Jaehark
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.95-104
    • /
    • 2019
  • Smoke generated in a fire consists of gaseous substances and particulate matter, such as unburned carbon that adsorbed the gases. Human injury caused by inhalation of gaseous substances present in smoke is mostly short-term, whereas damage caused by inhalation of particulate matter is relatively a long-term phenomenon depending on the state of the gas-phase adsorption. The amount and location of the deposited smoke particles are important factors in estimating the damage caused to humans, which are affected by the breathing conditions as well as particle conditions, such as the size and concentration affected by the combustion conditions. In this study, in order to understand the characteristics of the deposition of smoke particles in the respiratory tract related to the study of human smoke inhalation injury, the number and mass concentration of smoke particles deposited in different areas of the respiratory tract for different fuel types, combustion conditions and breathing conditions were calculated. In addition, the amount of mass deposition of smoke in the respiratory tract for a certain period of inhalation was compared with the atmospheric standard of fine dust.

Reduction of a Numerical Grid Dependency in High-pressure Diesel Injection Simulation Using the Lagrangian-Eulerian CFD Method (Lagrangian-Eulerian 기법을 이용한 고압 디젤 분무 시뮬레이션의 수치해석격자 의존성 저감에 관한 연구)

  • Kim, Sa-Yop;Oh, Yun-Jung;Park, Sung-Wook;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • In the standard CFD code, Lagrangian-Eulerian method is very popular to simulate the liquid spray penetrating into gaseous phase. Though this method can give a simple solution and low computational cost, it have been reported that the Lagrangian spray models have numerical grid dependency, resulting in serious numerical errors. Many researches have shown the grid dependency arise from two sources. The first is due to unaccurate prediction of the droplet-gas relative velocity, and the second is that the probability of binary droplet collision is dependent on the grid resolution. In order to solve the grid dependency problem, the improved spray models are implemented in the KIVA-3V code in this study. For reducing the errors in predicting the relative velocity, the momentum gain from the gaseous phase to liquid particles were resolved according to the gas-jet theory. In addition, the advanced algorithm of the droplet collision modeling which surmounts the grid dependency problem was applied. Then, in order to validate the improved spray model, the computation is compared to the experimental results. By simultaneously regarding the momentum coupling and the droplet collision modeling, successful reduction of the numerical grid dependency could be accomplished in the simulation of the high-pressure injection diesel spray.

Concentrations of Air Pollutants Measured at Kosan during ACE-Asia Intensive Observation Period (ACE-Asia 집중관측기간에 제주고산에서 측정한 대기오염물질의 농도 분포특성)

  • ;;;;Jianzhen Yu;Keith Bower
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.487-501
    • /
    • 2002
  • The concentrations of gaseous (NO$_{x}$, SO$_2$, and $O_3$) and particulate (Elemental Carbon, EC and Organic Carbon, OC) pollutants were measured to evaluate the air quality of Kosan. Samples were taken at Kosan during ACE-Asia (Asian Pacific Regional Aerosol Characterization Experiment) IOP (Intensive Observation Period) (2001. 3. 21~2001. 5. 5). The mean concentrations of $O_3$(46.3$\pm$10.4 ppb) is higher than those at urban area such as Seoul and Busan in Korea. On the other hand, the mean concentrations of other gaseous species, NO$_{x}$(4.73$\pm$3.42 ppb) and SO$_2$(0.62$\pm$0.63 ppb) are lower than those at great cities. So we concluded that there are a few primary sources emitting atmospheric pollutants. The concentration of EC is higher and the concentration of OC is similar with or higher than those at other background sites. The recent EC concentration is higher than those measured before at Kosan. We concluded that there are more primary sources than other background sites and the amount of primary source have increased recently in Jeju. Backward trajectory and co..elation analysis were used to study where the air masses originated and distinguish the source of pollutants. While NO$_{x}$ and $O_3$ were mainly emitted and formed from Jeju inland area, concentrations of SO$_2$, OC and EC were affected by Asian Dust from China. Using the mean relative standard deviation of ozone, cleanness coefficient was obtained. The cleanness coefficient value, is 1.6 times larger than the value in 1992. Recently, the air quality of Kosan has been contaminated because of the Asian Dust events since spring and the rapid industrialization development.pment.