• Title/Summary/Keyword: gaseous standard

Search Result 59, Processing Time 0.019 seconds

A Study of Calibration Bias in the Analysis of Airborne Carbonyl Compounds between Gaseous and Liquid-phase Standards by High Performance Liquid Chromatography (HPLC) (대기 중 Carbonyl 성분들의 검량 분석 기술에 대한 연구: 액상 대비 기체상 표준시료의 오차발생 특성 연구)

  • Lee, Min-Hee;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, the effect of standard phase difference in calibration of carbonyl compounds (CC) was evaluated by using their standards prepared in both gaseous and liquid phase. For this analysis, standards in both phases were prepared for 6 different CCs (formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA) and valeraldehyde (VA)) at similar concentration levels. Their gaseous standard was calibrated after derivatization with three types of DNPH cartridge, and their calibration results were compared against liquid-phase standards. Although there was a strong compatibility between 2 phases for CCs with lower molecular weights (e.g., formaldehyde and acetaldehyde), it was not the case for the heavier CCs. The results of our analysis indicate that the analytical bias of the heavier CCs can be significantly large (by more than a few tens of %). As a result, underestimation of hevier CCs can be significant, if their gaseous samples are quantified by liquid phase standard.

Concentration and Seasonal Variation of Gaseous Nitrous Acid in Seoul Air (서울대기중 아질산기체의 계절별 농도변화)

  • 이용근;김종욱;이동수;백선영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.24-31
    • /
    • 1994
  • Hourly variation of gaseous nitrous acid( HNO$_2$) concentration in Seoul air was monitored from Jan. 11 to SeP. 12, Nitrous acid concentration was determined by DS/IC over nine months of observation, HNO$_2$ range from 0.04 ppb to 5.5 ppb. Gor-tex tube as gaseous HNO$_2$generator in this study is thought to be more convenient and reproducible device than previous generator. As a result of NaOH instead of Na$_2$ CO$_3$/NaHCO$_3$ solution as the IC eluent, we could obtain more stable baseline. The concentration of the NaOH eluent was 15 mM . The limit of detection(3$\sigma$) of the liquid- Phase and gas phase nitrous acid of this method are 1.1ng/$m\ell$ , 0.04 n $\ell$ / $\ell$, respectively. The precisions evaluated by 10 replicate analysis of standard solution and standard gas generated are $\pm$1.59, $\pm$2. 89% RSD, respectively. Due to the lack of standard material for air, direct assessment of the accuracy was not possible. This study was applied to the analysis of Seoul ambient air and their results are reported herein.

  • PDF

Half lives of Gaseous Organochlorine Pesticides in Atmosphere (대기 중에서 가스상 유기염소계 살충제의 반감기)

  • Choi, Min-Kyu;Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.2 s.57
    • /
    • pp.177-184
    • /
    • 2007
  • Gaseous organochlorine pesticides (OCPs : heptachlor epoxide, p, p'-DDE, ${\gamma}-HCH,\;{\alpha}-chlordane,\;{\gamma}-chlordane$ and trans-nonachlor) concentration was measured using PUF high volume sampler from June, 2000 to June, 2002 in the semi-rural atmosphere. The OCPs concentration in atmosphere, which is estimated by the slope (m) of Clausius-Clapeyron equation and phase-transition energy $({\Delta}H)$, was influenced by revolatilization from environmental matrix (soil, water and tree leaves) and a long range transportation of air mass. But the former affected OCPs concentration more than the latter. The degradation rate constants (k) of OCPs calculated using multiple regression analysis and revised standard temperature method were in good agreement each other. The value of k of ${\gamma}-HCH$ was very low as -0.0007, but the range of k of other components were $-0.00l8{\sim}-0.0038$. The half-life $({\tau})$ which was calculated by k of ${\gamma}-HCH$ was 2.6 years-the longest one, but that of heptachlor epoxide was in 0.5 year-the shortest one. $({\tau})\;of\;{\alpha}-chlordane,\;{\gamma}-chlordane$ and trans-nonachlor in technical chlordane was 1.0, 1.1 and 0.7 year respectively.

A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems (가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구)

  • Son, Bong-Sei;Kim, Hee-Woo
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2007
  • This study aims to investigate, review, and summarize the definition, development, and applications of "percent agent in pipe", "percent of agent in pipe" which is used as a key factor in testing and evaluating the performance of gaseous fire extinguishing agents, including Halon 1301 and $CO_2$. This study also analyzes and compares the local and international standards on testing and evaluating the performance of gaseous fire extinguishing systems, as well as the results of system performance tests conducted as a part of performance evaluation and approval programs for gaseous fire extinguishing systems, especially, Korean Gaseous Fire Extinguishing System Performance Approval Program called KFI Approval. Percent agent in pipe was defined first in NFPA 12A, Standard on Halon 1301 Fire Extinguishing Systems, dating back to the 1970's. After the phaseout of Halon 1301 systems in 1994 in the developed countries, the percent agent in pipe has been widely used in Halon 1301 alternative clean agent fire extinguishing systems, both halocarbon clean agent systems and inert gas clean agent systems, as an essential criterion to assure the system design accuracy, determine the limitations and performance of a system, and to predict the system performance results accurately, especially, in association with their system flow calculations. Underwriters Laboratories has their own standards such as UL 2127 and 2166 applying percent agent in pipe in testing and evaluating the performance of clean agent fire extinguishing systems. As a part of a system performance test and approval program called KFI Approval System, Korea also has started to apply the percent agent in pipe as a key factor to test, evaluate, and approve the performance of gaseous fire extinguishing systems, including both high and low pressure $CO_2$ systems, from the early 2000's. This study outlines and summarizes the relevant UL and KFI standards and also describes the actual test resultant data, including the maximum percents of agent in pipe for gaseous fire extinguishing systems. As evidenced in lots of tests conducted as a part of the system performance test and approval programs like KFI Approval System, it has been proven that the percent agent in pipe may work as a key factor in testing, evaluating, and determining the limitations and performance of gaseous fire extinguishing systems, especially compared with the hydraulic flow calculations of computer design programs of gaseous fire extinguishing systems, and will remain as such in the future. As one thing to note, however, there are some difficulties in using the unified percent agent in pipe to determine the maximum lengths of pipe networks for gaseous fire extinguishing systems, because the varying definitions used by some of the flow calculations (not in accordance with NFPA 12A definition) make it impossible to do any direct comparison of pipe lengths based on percent agent in pipe.

A Study on Numerical Modeling of the Induced Heat to Gaseous Flow inside the Mixing Area of Ammonia SCR System in Diesel Nox After-treatment Devices (디젤 NOx 후처리 장치에 있어서 암모니아 SCR 시스템 혼합영역 내 가스유동의 유입열 수치모델링에 관한 연구)

  • Bae, Myung-Whan;Syaiful, Syaiful
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.897-905
    • /
    • 2008
  • Selective catalytic reduction(SCR) is known as one of promising methods for reducing $NO_x$ emissions in diesel exhaust gases. $NO_x$ emissions react with ammonia in the catalyst surface of SCR system at working temperature of catalyst. In this study, to raise the reacting temperature when the exhaust gas temperature is too low, a heater is located at the bottom of SCR reactor. At an ambient temperature, ammonia is radially injected perpendicular to the exhaust gas flow at inlet pipe and uniformly mixed in the mixing area after being impinged against the wall. To predict the turbulent model inside the mixing area of SCR system, the standard ${\kappa}\;-\;{\varepsilon}$ model is applied. This work investigates numerically the effects of induced heat on the gaseous flow. The results show that the Taylor-$G{\ddot{o}}rtler$ type vortex is generated after the gaseous flow impinges the wall in which these vortices influence the temperature distribution. The addition of heat disturbs the flow structure in bottom area and then stretching flow occurs. Vorticity strand is also formed when heat is continuously increased. Constriction process takes place, however, when a further heat input over a critical temperature is increased and finally forms shed vortex which is disconnected from the vorticity strand. The strong vortex restricts the heat transport in the gaseous flow.

A Study on the Fatigue Crack Growth Behavior of Cr-Mo- Steel for Pressure Vessel (압력용기용 Cr-Mo강의 균열진전거동에 관한 연구)

  • Choe, Byeong-Ik;Lee, Hak-Ju;Han, Seung-U;Kim, Chang-Uk;Cha, Jeong-Hwan;Kim, Jeong-Tae;Ji, Byeong-Ha
    • 연구논문집
    • /
    • s.29
    • /
    • pp.91-99
    • /
    • 1999
  • Fatigue crack growth behaviors of Cr-Mo steels developed recently for thick-wall pressure vessel were investigated. Experiments in accordance with ASTM E647 standard were performed for 1/2 inch CT specimens of $2^(1/4)$Cr-1Mo and 3Cr-IMo steels in gaseous environments, hydrogen gas of 10 atm, 1 atm and argon gas of 1 atm. Fatigue crack growth rates were observed and effects of gaseous hydrogen and argon on the crack growth behavior were discussed.

  • PDF

THE X-RAY EMISSION FROM EARLY TYPE GALAXIES

  • Kim, Dong-Woo
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.63-69
    • /
    • 1992
  • We have systematically investigated the X-ray spectra of normal galaxies, by using the Imaging Proportional Counter (IPC) data in the Einstein data base. We employed the X-ray color-color plot as well as the standard model fitting method which requires higher signal to noise ratio. We discuss X-ray emission mechanisms in terms of their spectral properties and the signature of cooling flows which are most likely present in X-ray bright early type galaxies. On the average, fits to absorbed thermal spectra show that the X-ray emission temperature of spirals is higher than that of ellipticals. This is consistent with our understanding that accreting binaries are a major X-ray source in spirals, while extended gaseous halos are present in ellipticals. The emission temperature becomes lower with increasing X-ray to optical luminosity ratio in E and S0 galaxies. This result is what we would expect if the emission of X-ray faint early type galaxies consists of a large evolved stellar component, while the gaseous emission becomes dominant in X-ray brighter galaxies. We also find a cool, self-absorbed core in some early type galaxies, which directly indicates the presence of cooling flows in such galaxies.

  • PDF

A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments (신축 공동주택 및 건축자재에서의 오염물질 방출 특성)

  • Kim Yun-Deok;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

The effect of relative humidity on the performance of DNPH-cartridge sampling for odorous aldehydes (악취성 Carbonyl 화합물의 카트리지 채취 분석: 습도가 채취효율에 미치는 영향)

  • Lee, Min-Hee;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.50-59
    • /
    • 2012
  • In this study, the effect of humidity change on DNPH cartridge sampling efficiency for carbonyl compounds (CCs) has been investigated. For this analysis, gaseous standard of 6 different CCs (formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA), and valeraldehyde (VA)) was calibrated after derivatization with three types of DNPH cartridge products. Their calibration results derived at RH values between 0 and 80% were then compared against liquid phase standards. If the results of our analysis are compared by the RH values between 20 and 80%, the effect of RH can be distinguished between light and heavy CCs. For lighter CCs (like FA and AA), there was no significant change. However, for the ones heavier than PA, there was fairly noticeable increase in relative recovery ratio in RH value between 20 and 80%. Such patterns are seen consistently from all three DNPH products tested for comparison. The results of our analysis suggest that proper correction for RH change may be needed for heavier CCs by the cartridge method.

Numerical Analysis of Recess Effects on Gaseous Hydrogen/Liquid Oxygen Coaxial Injector (수소-산소 동축 분사기에 대한 리세스 효과 수치해석)

  • Lee, Kibum;Park, Tae Seon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.17-24
    • /
    • 2016
  • The reacting flows of gaseous hydrogen/liquid oxygen 2D coaxial shear injector with varying recess length are numerically analyzed. The standard ${\kappa}-e$ model and laminar flamelet model are adopted for the steady turbulent combustion with the ideal and real gas equations. As the recess length increases, the recirculating region in the combustion chamber expands and the vorticity is intensified. Also, the variations of temperature, products, and pressure are strongly related to the recess length. The results show that an efficient combustor can be obtained by the introduction of the recessed injector.