• 제목/요약/키워드: gas-liquid contactor

검색결과 13건 처리시간 0.027초

Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor

  • Ho, Chii-Dong;Sung, Yun-Jen;Chen, Wei-Ting;Tsai, Feng-Chi
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.35-50
    • /
    • 2017
  • The theoretical membrane gas absorption module treatments in a hollow fiber gas-liquid membrane contactor using Happel's free surface model were obtained under countercurrent-flow operations. The analytical solutions were obtained using the separated variable method with an orthogonal expansion technique extended in power series. The $CO_2$ concentration in the liquid absorbent, total absorption rate and absorption efficiency were calculated theoretically and experimentally with the liquid absorbent flow rate, gas feed flow rate and initial $CO_2$ concentration in the gas feed as parameters. The improvements in device performance under countercurrent-flow operations to increase the absorption efficiency in a carbon dioxide and nitrogen gas feed mixture using a pure water liquid absorbent were achieved and compared with those in the concurrent-flow operation. Both good qualitative and quantitative agreements were achieved between the experimental results and theoretical predictions for countercurrent flow in a hollow fiber gas-liquid membrane contactor with accuracy of $6.62{\times}10^{-2}{\leq}E{\leq}8.98{\times}10^{-2}$.

PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성 (Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor)

  • 박현희;조항대;김인원;이형근
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.521-528
    • /
    • 2008
  • 중공사막 접촉기에 적절한 PVDF 중공사막을 상전이 공정에 의하여 제조하였으며, SEM 과 기체투과도에 의하여 그 특성을 분석하였다. 벤치규모 중공사막 접촉기에서 $SO_2$ 제거를 위한 흡수제는 수산화나트륨 수용액을 사용하였다. 기체는 shell side, 액체는 lumen side로 흐르는 counter-current로 실험하였으며, 흡수제의 농도, 기체의 유속, 액가스비, 유입 $SO_2$ 농도에 따른 영향을 알아보았으며, 수학적 모델링에 의해 막 물질전달계수($k_m$)를 측정하였다. 흡수제의 농도와 액기비가 증가함에 따라 기-액 계면에서 충분한 알칼리도가 제공되므로, 액체막 저항이 감소하며, 총괄물질전달 용량계수는 증가하였다. 기체유속이 증가함에 따라 기체막저항은 감소하게 되므로 총괄물질전달 용량계수는 증가하였다.

막접촉기 응용을 위한 직접 불소화를 통한 막의 표면개질 (Membrane Surface Modification through Direct Fluorination for Gas-Liquid Contactor)

  • 이형근;박보령;임지원;이상윤;황택성
    • 멤브레인
    • /
    • 제17권4호
    • /
    • pp.345-351
    • /
    • 2007
  • 본 연구에서는 선택적 Gas-Liquid Contactor의 성능을 향상시키기 위하여 polyethersulfone(PES), polysulfone(PSf), polyvinylidenefluoride (PVDF) 등의 막에 $F_2$ gas를 이용하여 표면개질하였다. 표면개질된 막의 특성을 알아보기 위해 SEM, 표면접촉각, XPS, 물 투과 최소 압력 실험을 수행하였다. SEM 측정으로부터 막의 표면형태를 살펴본 결과 불소처리 시간이 증가함에 따라 막 표면의 roughness가 증가함을 알 수 있었다. 표면불소화한 막 표면에 $-CF_2$, $-CF_3$의 perfluoro group이 화학적으로 결합되어 막의 소수성이 증가된 것으로 나타났다. 또한 표면접촉각 및 물 투과 최소 압력 실험으로부터 표면불소화 처리시간이 증가함에 따라 측정값이 증가하여 막의 특성이 향상됨을 알 수 있었다.

Recovery of ammonia from wastewater by liquid-liquid membrane contactor: A review

  • Jang, Yoonmi;Lee, Wooram;Park, Jaebeom;Choi, Yongju
    • Membrane and Water Treatment
    • /
    • 제13권3호
    • /
    • pp.147-166
    • /
    • 2022
  • Liquid-liquid membrane contactor (LLMC), a device that exchanges dissolved gas molecules between the two sides of a hydrophobic membrane through membrane pores, can be employed to extract ammoniacal nitrogen from a feed solution, which is transported across the membrane and accumulated in a stripping solution. This LLMC process offers the promise of improving the sustainability of the global nitrogen cycle by cost-effectively recovering ammonia from wastewater. Despite recent technological advances in LLMC processes, a comprehensive review of their feasibility for ammonia recovery is rarely found in the literature. Our paper aims to close this knowledge gap, and in addition to analyze the challenges and provide potential solutions for improvement. We begin with discussions on the operational principles of the LLMC process for ammonia recovery and membrane types and membrane configurations commonly used in the process. We then assess the performance of the process by reviewing publications that demonstrate its practical application. Challenges involved in the implementation of the LLMC process, such as membrane fouling, membrane wetting, and chemical requirements, are presented, along with discussions on potential strategies to address each. These strategies, including membrane modification, hybrid process design, and process optimization based on cost-benefit analysis, guide the reader to identify key areas of future research and development.

Gas 분산 기-액 반응조에서 기포운동이 열전달에 미치는 영향

  • 손병진;이현
    • 대한설비공학회지:설비저널
    • /
    • 제8권1호
    • /
    • pp.10-13
    • /
    • 1979
  • The study for bubbling phenomena to influence heat transfer in gas - liquid contactors. The sparged contactor is gaining importance for gas-liquid chemical reactions. In this paper, correlations between Reynolds number and heat transfer coefficient were studied and experimental expressions were also obtained over broth of areas, namely, laminar area and turbulent area respectively.

  • PDF

중공사막 접촉기를 이용한 암모니아 물질전달 모델링 (Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor)

  • 오대양;정주영;최원호;박주양
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.

고투과성 세라믹 중공사 개발과 접촉막 공정의 CH4/CO2 분리 특성 평가 (Development of High-Permeability Ceramic Hollow Fiber and Evaluation of CH4/CO2 Separation Characteristics of Membrane Contactor Process)

  • 이승환;김민광;정병준;장학룡;박정훈
    • 멤브레인
    • /
    • 제30권4호
    • /
    • pp.269-275
    • /
    • 2020
  • 본 연구에서는 세라믹 중공사 접촉막 모듈을 이용하여 CH4/CO2 혼합가스에서 CO2 분리 실험을 수행하였다. 높은 성능의 접촉막 모듈을 제작하기 위해 고투과성 중공사막의 제조 실험을 진행하였으며, 제조한 중공사막은 N2 기체투과실험을 통해 투과 성능을 평가하였다. 최종적으로 고투과도 중공사막을 이용하여 CH4/CO2 혼합 기체 분리를 위한 Hollow fiber membrane contactor (HFMC)를 제작하였다. 실험에는 CH4/CO2 혼합 기체(34.5% CO2, CH4 balance)와 monoethanolamine (MEA)를 사용하였으며, CO2 제거 효율이 흡수제의 유량에 따라 어떠한 영향을 받는지 평가하였다. CO2 제거 효율은 액체유량이 증가함에 따라 같이 상승하였으며, CO2 흡수 flux 또한 액체유량과 함께 증가하는 결과를 보였다.

분리막 접촉기의 기술 동향 (Thends in Membrane Contactors)

  • 이규호;김민정;서봉국;박유인;이기섭
    • 멤브레인
    • /
    • 제15권3호
    • /
    • pp.187-197
    • /
    • 2005
  • 분리막 접촉기는 액체-액체, 기체-액체와 같이 두 개의 다른 상 사이에 막이 상계면 혹은 상 장벽의 역할을 수행하여 두 상간의 물질전달이 이루어지게 하는 장치이다 분리막 접촉기는 기체-액체 또는 액체-액체 간에 접촉을 통해 안정된 계면을 형성시켜줌으로써 인위적으로 물질전달속도 조절이 가능할 뿐만 아니라 접촉면적이 크고 기존 분리정제 공정의 운전 시 발생할 수 있는 유화(emulsion), 범람(flooding), 편류(channeling), 기포생성(foaming), 그리고 부하(unloading) 등과 같은 기술적 문제점을 보완할 수 있어 이에 대한 연구가 활발히 진행되고 있다. 이에 본 논문에서는 분리막 접촉기가 이용되는 공정과 분리막 접촉기에 사용되는 막의 제조방법, 국내외의 연구동향을 고찰하여 분리공정으로써의 분리막 접촉기에 관한 이해를 높이고자 한다.

순환식 고분자 분리막 접촉기를 이용한 이산화황 분리 (Separation of Sulfur Dioxide by Circulatory Porous Polymer Membrane Contactor)

  • 이용택;전현수;안효성;송인호;정헌규;이형근
    • 멤브레인
    • /
    • 제17권4호
    • /
    • pp.302-310
    • /
    • 2007
  • 이산화황 흡수 수용액이 다공성 분리막 접촉기를 연속적으로 순환하는 시스템에서 다양한 운전변수에 따른 이산화황의 분리 효율을 고찰하였다. 공급 기체로는 이산화황/공기 혼합 기체를 사용하였으며 흡수제로는 $Na_2SO_3$ 수용액을 사용하였다. 운전 변수들인 흡수제 농도와 공급 기체 내의 이산화황 농도, 분리막 재질, 흡수제 유속 변화에 따른 분리 효율에 대한 영향을 확인하고자 하였다. 흡수제의 농도 0.05 M에서 0.2 M로 증가할수록 이산화황 제거 효율은 74%에서 100%로 증가하였다. 이산화황 농도가 700 ppm에서 2,500 ppm으로 증가할수록 제거 효율은 100%에서 75%로 감소하였다. 또한 흡수제의 유속이 2.5 mL/min에서 15 mL/min으로 증가할수록 제거 효율은 85%에서 100%로 증가하였고, 분리막은 기공률이 클수록 제거 효율이 증가함을 확인할 수 있었다.