• Title/Summary/Keyword: gas-discharge

Search Result 1,514, Processing Time 0.031 seconds

A Study on a Superposed Discharge Type Ozonizer(I) (중첩방전형 오존발생기에 관한 연구(I))

  • Song, Hyun-Jig;Woo, Sung-Hun;Lee, Keun-Sang;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In;Lee, Dong-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1724-1726
    • /
    • 1997
  • In this paper, a superposed discharge type ozonizer(CISDO) has been designed and manufactured. CISDO is equipped with three electrodes(central electrode, internal electrode and external electrode), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following two characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quality of supplied gas and discharge voltage (2) The characteristics of ozone generation with variation of quality of supplied gas. discharge power, operating number.

  • PDF

Study on Insulation Diagnosis of Poor Contact between Electrode and Solid Insulator in Eco-Gas (친환경 가스 중 전극과 고체절연체의 불량접촉에 관한 절연진단연구)

  • Lim, Dong-Young;Choi, Eun-Hyeok;Bae, Sungwoo;Choi, Sang-Tae;Lee, Kwang-Sik;Choi, Byoung-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.97-103
    • /
    • 2015
  • This paper presents the characteristics of partial discharge and radiated electromagnetic waves in the existence of a poor contact for the insulation diagnosis of eco-friendly power equipment. AC surface discharge experiment was conducted to simulate the poor contact between a hive voltage electrode (anode) and a solid insulator in $N_2/O_2$ mixture gas under a non-uniform field. The partial discharge voltage to be measured at 0.3MPa increased with the increase of the poor contact gap and was saturated with the gap. In addition to the partial discharge characteristics, it was verified that the defect of the poor contact can be diagnosed using the radiated electromagnetic waves due to the partial discharge, which measured by a biconical EMC antenna and a spectrum analyzer.

The removal characteristics of No, SOx for plasma reactor separated flue gas duct from discharge domain (연소가스관로와 방전영역 분리형 플라즈마 반응기에서 Nox, SOx 제거특성)

  • Park, J.Y.;Koh, Y.S.;Lee, J.D.;Song, W.S.;Park, S.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2007-2009
    • /
    • 1999
  • In this paper, discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution. Ammonia gas(14.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio[MR] was determined based on $NH_3$ to [NO+$SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration but SOx removal rate was not significantly effect by initial concentration, and NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Estimation Methods for Turbine Nozzle Throat Area Reduction of A LOx/Kerosene Gas Generator Cycle Liquid Propellant Rocket Engine (액체산소/케로신 가스발생기 사이클 액체로켓엔진 터빈 노즐목 면적 변화 추정 방법)

  • Nam, Chang-Ho;Moon, Yoonwan;Park, Soon Young;Kim, Jinhan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.101-106
    • /
    • 2019
  • Carbon deposition on the turbine nozzle throat of a LOx/kerosene gas generator cycle(open cycle) engine causes performance reduction of the engine. Estimation methods for a turbine nozzle throat area are proposed. The discharge coefficient of the turbine nozzle was estimated with the turbine gas properties such as gas constant, specific heat ratio, and temperatures. The pressure ratio and temperature ratio of the turbine nozzle throat, was utilized to estimate the discharge coefficient also. Estimated discharge coefficient of turbine nozzle throat of KSLV-II 1st stage engine shows the carbon deposition effects on the turbine nozzle throat of a LOx/kerosene open cycle engine.

Comprehensive Consideration on the Discharge of Gases from Pressurized Vessels through Pressure Relief Devices (압력용기로부터 압력방출장치를 통한 가스 방출에 관한 포괄적 고찰)

  • Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.32-45
    • /
    • 2020
  • The problem of determining the discharge rates of gases from pressurized vessels through pressure relief devices was dealt with comprehensively. First, starting from basic fluid flow equations, detailed modeling procedures were presented for isentropic nozzle flows and frictional flows in a pipe, respectively. Meanwhile, physical explanations were given to choking phenomena in terms of the acoustic velocity, elucidating the widespread use of Mach numbers in gas flow models. Frictional flows in a pipe were classified into adiabatic, isothermal, and general flows according to the heat transfer situation around the pipe, but the adiabatic flow model was recommended suitable for gas discharge through pressure relief devices. Next, for the isentropic nozzle flow followed by adiabatic frictional flow in the pipe, two equations were established for two unknowns that consist of the Mach numbers at the inlet and outlet of the pipe, respectively. The relationship among the ratio of downstream reservoir pressure to upstream pressure, mass flux, and total frictional loss coefficient was shown in various forms of MATLAB 2-D plot, 3-D surface plot and contour plot. Then, the profiles of gas properties and velocity in the pipe section were traced. A method to quantify the relationship among the pressure head, velocity head, and total friction loss was presented, and was used in inferring that the rapid increase in gas velocity in the region approaching the choked flow at the pipe outlet is attributed to the conversion of internal energy to kinetic energy. Finally, the Levenspiel chart reproduced in this work was compared with the Lapple chart used in API 521 Standatd.

Effect of Non-uniform Concentration on Gas Explosion (불균일 농도가 가스 폭발에 미치는 영향)

  • Kim Sang Sub;Jang Gi Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.14-19
    • /
    • 2003
  • Generally the accident by gas explosion in the working place is occurred at the condition of non-uniform mixture rather than uniform one. This study could predict the explosion phenomenon of non-uniform mixture with model explosion chamber which realize various practical conditions As a result, the mixing level of gas in the chamber depends on discharge area and velocity when there is gas discharge in certain space. In addition, as non-uniform increases, explosion pressure and its increasing rate decrease. However, firing risk after the explosion flame by infrared heat increase due to the increase of residence time of flame.

  • PDF

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

The Simulated study of different partial discharge sources in GIS (모의된 GIS에서 발생하는 부분방전에 관한 연구)

  • Kang, Dae-Yong;Wu, Guangning;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1737-1739
    • /
    • 1998
  • The paper presents experimental results of Partial Discharge(PD) in Gas Insulated Switchgear(GIS), obtained using a computer-aided PD measurement system. Different discharge sources are simulated and identified. These included internal, interface, surface and protrusion. For internal discharge, it showed symmetrical discharge type between positive and negative cycle. Interface discharge showed smaller number and higher peak than internal discharge but symmetrical discharge as well. For surface discharge, it showed small number and high peak in positive half cycle but large number and low peak in negative half cycle. For protrusion discharge, small number and high peak of discharge were shown only in negative half cycle.

  • PDF

Performance Enhancement of Gas-Liquid Mixed Plasma Discharge System using High Speed Agitation (고속 교반을 이용한 기-액 혼합 플라즈마방전 시스템의 성능 향상)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.26 no.6
    • /
    • pp.711-717
    • /
    • 2017
  • Dielectric Barrier Discharge (DBD) plasma is a new technique for use in environmental pollutant degradation, which is characterized by the production of hydroxyl radicals as the primary degradation species. Due to the short lifetime of the chemically active species generated during the plasma reaction, the dissolution of the plasma gas has a significant effect on the reaction performance. The plasma reaction performance can be enhanced by combining the basic plasma reactor with a homogenizer system in which the bubbles are destroyed and turned into micro-bubbles. For this purpose, the improvement of the dissolution of plasma gas was evaluated by measuring the RNO (N-dimethyl-4-nitrosoaniline, an indicator of the generation of OH radicals). Experiments were conducted to evaluate the effects of the diameter, rotation speed, and height of the homogenizer, pore size, and number of the diffuser and the applied voltage on the plasma reaction. The results showed that the RNO removal efficiency of the plasma reactor combined with a homogenizer is two times higher than that of the conventional one. The optimum rotor size and rotation speed of the homogenizer were 15.1 mm, and 19,700 rpm, respectively. Except for the lowest pore size distribution of $10-16{\mu}m$, the pore size of the diffuser showed little effect on RNO removal.

Discharge Characteristics of Xe Plasma Flat Lamp for LCD Backlight According to Operating Voltage Pulse (LCD 백라이트용 Xe계 플라즈마 평판 램프의 구동 전압 Pulse의 조건에 따른 방전 특성 연구)

  • Kwon, Eun-Mi;Kim, Hyuk-Hwan;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.13 no.4
    • /
    • pp.271-278
    • /
    • 2003
  • Conventional backlight for liquid crystal display (LCD) uses mercury which leads to environmental pollution. In this study, characteristics of AC coplanar type mercury-free plasma flat lamp have been studied. Pollution-free Xe-He is adopted as a discharge gas system. Since the Xe gas has a lower efficiency in generating vacuum ultraviolet (VUV) than mercury, the improvement of luminance and luminous efficiency in the Xe gas system is very important. The electrode, dielectric, and phosphor layers constituting lamp are formed on the bottom glass by the screen printing method. The effects of pulse shape, on-time, and pulse frequency on the luminance and luminous efficiency have been examined. For Xe(5%)-He gas, the lamp exhibits higher efficiency with sharper pulse shape, higher peak voltage, and shorter pulse on-time (up to 2 $\mu\textrm{s}$). Higher efficiency and lower consumption of power were obtained at 30 kHz than at 60 kHz. The collision of ion to bottom electrodes is a dominant factor to raise the lamp temperature. Therefore the high voltage and low current discharge system is necessary for reduction of the lamp temperature as well as for enhancement of the luminous efficiency.