• Title/Summary/Keyword: gas volume

Search Result 1,565, Processing Time 0.028 seconds

Improvement of Oxygen Isotope Analysis in Seawater samples with Stable Isotope Mass Spectrometer (질량분석기를 이용한 해수 중 산소안정동위원소 분석법의 개선)

  • Park, Mi-Kyung;Kang, Dong-Jin;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Oxygen isotope has not been used actively in water mass studies because of difficulties on the analysis though it has advantages as a water mass tracer. The most popular method to analysis the oxygen isotope ratio in water samples is equilibration method: isotopic equilibrium of water with $CO_2$ at constant temperature. The precision of oxygen isotope analysis using commercial automatic $H_2O/CO_2$ equilibrator is ${\pm}0.1%o$. This value is not sufficient for studies in open ocean. The object of this study is to improve the analytical precision enough to apply open ocean studies by modification of the instrument. When sample gas is transferred by the pressure difference, the fractionation which is preferential transportation of light isotope can be occurred since the long transportation path between the equilibrator and mass spectrometer. And the The biggest source of error during the analysis is long distance and large volume of the pathway of sample gas between. Therefore, liquid nitrogen trap and high vacuum system are introduced to the system. The precisions of 14 time analysis of same seawater sample are ${\pm}0.081%o$ and ${\pm}0.021%o$ by built-in system and by modified system in this study, respectively.

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Clinical Efficacy of Erdosteine in Patients with Acute or Chronic Bronchitis -A Randomized, Double Blind, Comparative Study vs. Ambroxol- (급.만성 기관지염 환자에서 엘도스$^{(R)}$(Erdosteine)의 임상효과 -염산 암브록솔과의 무작위 이중맹검 비교시험-)

  • Kim, Seok-Chan;Lee, Sang-Hoak;Song, So-Hyang;Kim, Young-Kyoon;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1296-1307
    • /
    • 1997
  • Background : Erdosteine is a thiol derivative developed for the treatement of chronic obstructive bronchitis, including acute infective exacerbation of chronic bronchitis. Erdosteine has mucomodulating and antioxidant properties and especially exhibits excellent gastrointestinal tolerability. Methods : The study was conducted as a prospective evaluation, with 2 comparative groups orally treated with erdosteine 300mg (bid.) or ambroxol 30mg (b.i.d.) for 7 days and the design of trial was double-blind. The treatments have been assigned randomly to patients (n=80) with acute or chronic bronchitis. The primary end-point used to determine efficacy in this study was subjective symptoms including expectorating frequence, expectoration volume, expectorating difficulty, expectoration viscosity, cough intensity and dyspnea. The secondary end-points of efficacy was the result of arterial blood gas analysis and pulmonary function test. Safety was evaluated with adverse drug reactions and laboratory tests monitoring. 61 patients was included in the efficacy analysis, due to the fact that 19 patients drop-out for different reasons. The obtained values have been analyzed with paired Hest., ANOVA test., multivariate $t^2$-test, repeated measures analysis of covariance, two sample t-test, loglinear-logit model analysis, Fisher's exact test. Results : 1) There was no significant difference on demographic data and vital signs between erdosteine and ambroxol treated groups. 2) The comparison between erdosteine and ambroxol treated groups showed no significant difference in improvement of each symptom in spite of the more favorable efficacy obtained with erdosteine. No difference on the contrary was observed for arterial blood gas analysis and pulmonary function test. 3) As safety is concerned, no clinical significant changes in laboratory test and symptom were induced in erdosteine and ambroxol treated group and two patients in ambroxol treated group drop-out for adverse reactions in symptom. 4) In the evaluation of final clinical efficacy, erdosteine improved more effectively patient's overall symptoms {very good effect (11/31), good effect (12/31), moderate effect (6/31), no effect (2/31), aggravation (0/31)} than ambroxol {very good effect (6/30), good effect (14/30), moderate effect (5/30), no effect (4/30), aggravation (2/30)}. And the probability of symptomatic improvement by erdosteine compared to ambroxol was 2.5 times. (p<0.05). Conclusion : This study showed that erdosteine was clinically effective and safe drug for treatment of acute and chronic bronchitis.

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Analysis of the Factors Affecting Anaerobic Thermophilic Digestibility of Food Wastes (음식물쓰레기의 고온 혐기성 소화도에 미치는 요소에 대한 분석)

  • Kim, Do Hee;Hyun, Seung Hoon;Kim, Kyung Woong;Cho, Jaeweon;Kim, In S.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.130-139
    • /
    • 2000
  • Serial basic tests were conducted for the determination of fundamental kinetics and for the actual application of kinetic parameter to food waste digestion with precise measurement of methane production under a thermophilic condition. The effects of food particle size, sodium ion concentration, and volatile solid (VS) loading rate on the anaerobic thermophilic food waste digestion process were investigated. Results of serial test for the determination of fundamental kinetic coefficients showed the value of k (maximum substrate utilization rate coefficient) and KS (half-saturation coefficient) as $0.24hr^{-1}$ and $700mg/{\ell}$, respectively, for non-inhibiting organic loading range. No inhibition effect was shown until $5g/{\ell}$ of sodium ion concentration was applied to a serum bottle reactor. However, the volume of methane gas was decreased gradually when the concentrations of more than $5g/{\ell}$ of sodium ion applied. All sizes of food waste particle showed the same constants (A : 0.45) but the maximum substrate utilization rate constant ($k_{HA}$) was inversely proportional to particle size. As an average particle size increased from 1.02 mm to 2.14 mm, $k_{HA}$ decreased from $0.0033hr^{-1}$ to $0.0015hr^{-1}$. The result reveals that particle size is one of the most important factors in anaerobic food waste digestion. There was no inhibition effect of sodium ion when VS loading rate was $30g/{\ell}$. And maximum injection concentration of VS loading rate was determined about $40g/{\ell}$.

  • PDF

Evaluation of $^{14}C$ Behavior Characteristic in Reactor Coolant from Korean PWR NPP's (국내 경수로형 원자로 냉각재 중의 $^{14}C$ 거동 특성 평가)

  • Kang, Duk-Won;Yang, Yang-Hee;Park, Kyong-Rok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This study has been focused on determining the chemical composition of $^{14}C$ - in terms of both organic and inorganic $^{14}C$ contents - in reactor coolant from 3 different PWR's reactor type. The purpose was to evaluate the characteristic of $^{14}C$ that can serve as a basis for reliable estimation of the environmental release at domestic PWR sites. $^{14}C$ is the most important nuclide in the inventory, since it contributes one of the main dose contributors in future release scenarios. The reason for this is its high mobility in the environment, biological availability and long half-life(5730yr). More recent studies - where a more detailed investigation of organic $^{14}C$ species believed to be formed in the coolant under reducing conditions have been made - show that the organic compounds not only are limited to hydrocarbons and CO. Possible organic compounds formed including formaldehyde, formic acid and acetic acid, etc. Under oxidizing conditions shows the oxidized carbon forms, possibly mainly carbon dioxide and bicarbonate forms. Measurements of organic and inorganic $^{14}C$ in various water systems were also performed. The $^{14}C$ inventory in the reactor water was found to be 3.1 GBq/kg in PWR of which less than 10% was in inorganic form. Generally, the $^{14}C$ activity in the water was divided equally between the gas- and water- phase. Even though organic $^{14}C$ compound shows that dominant species during the reactor operation, But during the releasing of $^{14}C$ from the plant stack, chemical forms of $^{14}C$ shows the different composition due to the operation conditions such as temperature, pH, volume control tank venting and shut down chemistry.

  • PDF

A Study on the Current Fire Insurance Subscription and Solutions for Ensuring the Safety of the Traditional Market (전통시장 안전성 확보를 위한 개선방안: 화재보험 가입실태를 중심으로)

  • Kim, Yoo-Oh;Byun, Chung-Gyu;Ryu, Tae-Chang
    • Journal of Distribution Science
    • /
    • v.9 no.4
    • /
    • pp.43-50
    • /
    • 2011
  • Concerning the risk factors of the outbreak of a fire in a traditional market, most of those markets are located in downtown areas or residential areas; thus, although their location may be favorable in terms of marketability, they face a potential risk in that a fire may develop into a large blaze owing to poor environment or the absence of facilities prepared for disaster during a fire. Moreover, as many people are densely poised in the markets, it is very probable that a fire may occur owing to the excessive use of heaters in the winter as well as the reckless use of electric and gas facilities. It seems that traditional markets encounter difficulty being insured against fire, because of their vulnerability and that the vast majority of small-scale sellers are likely to suffer mental anguish and tremendous physical injury in case of a fire. However, most of those sellers in the traditional markets are hand-to-mouth sellers, and they lack awareness of safety concerns and have insufficient experience in safe facility management. As small-scale sellers constitute the majority in the traditional market, the subscription rate of fire insurance in most of the traditional markets is low for the reasons of their needy circumstances and their financial burden. Statistically, the subscription by street vendors is non-existent; therefore, these vendors have a fairly limited access to indemnification after fire damage. Because of these problems, this study's purpose is to identify the current level of insurance subscription by these markets, which are exposed to poor facilities and vulnerability to fire. In order to fix this, it appears that shop owners and consumers will have to band together. For this study, we executed a fire policyholder fact-finding mission at traditional markets with approximately 108 and 981 stores. The research method was executed by an investigation using one-on-one individual interviews using a questionnaire. The contents investigated current insurance subscriptions. The method of analysis looked at the difference of insured amount according to volume size through cross-tabulation of the difference of insured amount by possession form, difference of insured amount by market form, difference of insured amount by category of business, difference of insured amount by market size, etc. Furthermore, the study should be used to propose solutions for problems through theoretical review with the use of a literature research, because the field case study was through interviews with the persons concerned, and the survey of the current insurance subscriptions by traditional market shopkeepers. The traditional market would generally have difficulty affording fire insurance. Fire insurance subscription rates of most of the market proved to be inactive, because of the economic burden of payment. Lack of funds is thought to be the main factor that causes a lack of realization about the necessity of fire insurance. In addition to expensive insurance premiums, sometimes, the companies' valuation of the businesses is lower than their actual valuations, and they do not pay out enough during a claim. The research presents an improvement plan that, when presented at the traditional markets, may strengthen their ability to procure fire insurance through the help of the central government. Researchers connected with the traditional market mainly accomplish the initial research. However, although this research has its limitations, it offers considerable benefits. For future researchers, I would suggest looking at several regions for comparison.

  • PDF

Estimation of surface nitrogen dioxide mixing ratio in Seoul using the OMI satellite data (OMI 위성자료를 활용한 서울 지표 이산화질소 혼합비 추정 연구)

  • Kim, Daewon;Hong, Hyunkee;Choi, Wonei;Park, Junsung;Yang, Jiwon;Ryu, Jaeyong;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.135-147
    • /
    • 2017
  • We, for the first time, estimated daily and monthly surface nitrogen dioxide ($NO_2$) volume mixing ratio (VMR) using three regression models with $NO_2$ tropospheric vertical column density (OMIT-rop $NO_2$ VCD) data obtained from Ozone Monitoring Instrument (OMI) in Seoul in South Korea at OMI overpass time (13:45 local time). First linear regression model (M1) is a linear regression equation between OMI-Trop $NO_2$ VCD and in situ $NO_2$ VMR, whereas second linear regression model (M2) incorporates boundary layer height (BLH), temperature, and pressure obtained from Atmospheric Infrared Sounder (AIRS) and OMI-Trop $NO_2$ VCD. Last models (M3M & M3D) are a multiple linear regression equations which include OMI-Trop $NO_2$ VCD, BLH and various meteorological data. In this study, we determined three types of regression models for the training period between 2009 and 2011, and the performance of those regression models was evaluated via comparison with the surface $NO_2$ VMR data obtained from in situ measurements (in situ $NO_2$ VMR) in 2012. The monthly mean surface $NO_2$ VMRs estimated by M3M showed good agreements with those of in situ measurements(avg. R = 0.77). In terms of the daily (13:45LT) $NO_2$ estimation, the highest correlations were found between the daily surface $NO_2$ VMRs estimated by M3D and in-situ $NO_2$ VMRs (avg. R = 0.55). The estimated surface $NO_2$ VMRs by three modelstend to be underestimated. We also discussed the performance of these empirical modelsfor surface $NO_2$ VMR estimation with respect to otherstatistical data such asroot mean square error (RMSE), mean bias, mean absolute error (MAE), and percent difference. This present study shows a possibility of estimating surface $NO_2$ VMR using the satellite measurement.

Proposal of New Criteria for Assessing Respiratory Impairment (새로운 호흡기 장애 판정 기준의 제안)

  • Park, Joo-Hun;Lee, Jae-Seung;Huh, Jin-Won;Oh, Yeon-Mok;Lee, Sang-Do;Lee, Sei-Won;Yoon, Ho-Il;Kim, Deog-Kyeom;Lee, Chang-Hoon;Park, Myung-Jae;Kim, Eun-Kyung;Park, Yong-Bum;Hwang, Yong-Il;Jung, Ki-Suck;Park, Hye-Yoon;Lim, Seong-Yong;Jung, Ji-Ye;Kim, Young-Sam;Kim, Hui-Jung;Rhee, Chin-Kook;Yoon, Hyoung-Kyu;Kim, Young-Kyoon;Kim, Jin-Woo;Yoo, Jee-Hong;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • Social welfare services for respiratory-disabled persons in Korea are offered based on the respiratory impairment grade, which is determined by 3 clinical parameters; dyspnea, forced expiratory volume in 1 second ($FEV_1$), and arterial oxygen tension. This grading system has several limitations in the objective assessment of respiratory impairment. We reviewed several guidelines for the evaluation of respiratory impairment and relevant articles. Then, we discussed a new grading system with respiratory physicians. Both researchers and respiratory physicians agreed that pulmonary function tests are essential in assessing the severity of respiratory impairment, forced vital capacity (FVC), $FEV_1$ and single breath diffusing capacity ($DL_{co}$) are the primarily recommended tests. In addition, we agreed that arterial blood gas analysis should be reserved for selected patients. In conclusion, we propose a new respiratory impairment grading system utilizing a combination FVC, $FEV_1$ and $DL_{co}$ scores, with more social discussion included.

Effect of Composition of γ-Al2O3/SiO2 Mixed Support on Fischer-Tropsch Synthesis with Iron Catalyst (철 기반 촉매의 Fischer-Tropsch 합성에서 γ-Al2O3/SiO2 혼합 지지체 조성의 영향)

  • Min, Seon Ki;No, Seong-Rae;You, Seong-sik
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.436-442
    • /
    • 2017
  • Fischer-Tropsch synthesis is the technology of converting a syngas (CO+$H_2$) derived from such as coal, natural gas and biomass into a hydrocarbon using a catalyst. The catalyst used in the Fischer-Tropsch synthesis consists of active metal, promoter and support. The types of these components and composition affect the reaction activity and product selectivity. In this study, we manufactured an iron catalyst using ${\gamma}-Al_2O_3/SiO_2$ mixed support (100/0 wt%, 75/25 wt%, 50/50 wt%, 25/75 wt%, 0/100 wt%) by an impregnation method to investigate how the composition of ${\gamma}-Al_2O_3/SiO_2$ mixed support effects on the reaction activity and product selectivity. The physical properties of catalyst were analyzed by $N_2$ physical adsorption and X-Ray diffraction method. The Fischer-Tropsch synthesis was conducted at $300^{\circ}C$, 20bar in a fixed bed reactor for 60h. According to the results of the $N_2$ physical adsorption analysis, the BET surface area decreases as the composition of ${\gamma}-Al_2O_3$ decreases, and the pore volume and pore average diameter increase as the composition of ${\gamma}-Al_2O_3$ decreases except for the composition of ${\gamma}-Al_2O_3/SiO_2$ of 50/50 wt%. By the results of the X-Ray diffraction analysis, the particle size of ${\alpha}-Fe_2O_3$ decreases as the composition of ${\gamma}-Al_2O_3$ decreases. As a result of the Fischer-Tropsch synthesis, the CO conversion decreases as the composition of ${\gamma}-Al_2O_3$ decreases, and the selectivity of C1-C4 decreases until the composition of ${\gamma}-Al_2O_3$ was 25 wt%. In contrast, the selectivity of C5+ increases until the composition of ${\gamma}-Al_2O_3$ is 25 wt%.